Reproducibility evaluation of the use of pressure conserving abdominal compressor in lung and liver volumetric modulated arc therapy  

Park, ga yeon (Radiation Oncology Department, Yong-in Severance Hospital)
Kim, joo ho (Radiation Oncology Department, Yong-in Severance Hospital)
Shin, hyun kyung (Radiation Oncology Department, Yong-in Severance Hospital)
Kim, min soo (Radiation Oncology Department, Yong-in Severance Hospital)
Publication Information
The Journal of Korean Society for Radiation Therapy / v.33, no., 2021 , pp. 71-78 More about this Journal
Abstract
Purpose: To evaluate the inter-fractional position and respiratory reproducibility of lung and liver tumors using pressure conserving type(P-type) abdominal compressor in volumetric modulated arc therapy(VMAT). Materials and methods: Six lung cancer patients and three liver cancer patients who underwent VMAT using a P-type abdominal compressor were included in this study. Cone-beam computed tomography(CBCT) images were acquired before each treatment and compared with planning CT images to evaluate the inter-fractional position reproducibility. The position variation was defined as the difference of position shift values between target matching and bone matching. 4-dimensional cone-beam computed tomography(4D CBCT) images were acquired weekly before treatment and compared with planning 4DCT images to evaluate the inter-fractional respiratory reproducibility. The respiratory variation was calculated by the magnitude of excursions by breathing. Results: The mean ± standard deviation(SD) of overall position variation values, 3D vector in the three translational directions were 1.1 ± 1.4 mm and 4.5 ± 2.8 mm for the lung and liver, respectively. The mean ± SD of respiratory variation values were 0.7 ± 3.4 mm (p = 0.195) in the lung and 3.6 ± 2.6 mm (p < 0.05) in the liver. Conclusion: The use of P-type compressor in lung and liver VMAT was effective for stable control of inter-fractional position and respiratory variation by reproduction of abdominal compression. Appropriate PTV margin must be considered in treatment planning, and image guidance before each treatment are required in order to obtain more stable reproducibility
Keywords
Abdominal compression; Pressure conserving compression; Lung cancer radiotherapy; Liver cancer radiotherapy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Negoro Y., Nagata Y., Aoki T. et al.: The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: reduction of respiratory tumor movement and evaluation of the daily setup accuracy. Int J Radiation Oncol Biol Phys. 2001;50(4):889-898   DOI
2 Keall P.J., Mageras G.S., Balter J.M. et al.: The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys. 2006;33(10):3874-3900.   DOI
3 Kim T H, Kim S, Kim D S et al.: Development of real time abdominal compression force monitoring and visual biofeedback system Phys. Med. Biol. 2018; 63(05) 055014   DOI
4 Chunhui H., Sagus S., Timothy E. S. et al.: Variations of target volume definition and daily target volume localization in stereotactic body radiotherapy for early-stage non-small cell lung cancer patients under abdominal compression. Med Dosim. 2017;42:116-121   DOI
5 Bissonnette J P, Franks K N, Purdie T G et al.: Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography Int. J. Radiat. Oncol. Biol. Phys. 2009; 75(3):688-695   DOI
6 Mampuya, W.A., Nakamura, M., Matsuo, Y. et al.: Interfraction variation in lung tumor position with abdominal compression during stereotactic body radiotherapy. Med. Phys. 2013; 40(9): 091718   DOI
7 우중열, 김주호, 김준원 등: 토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가. 대한방사선치료학회지 2012; 24(2):157-165
8 Javadi S, Eckstein J, Ulizio V.: Evaluation of the use of abdominal compression of the lung in stereotactic radiation therapy. Med Dosim. 2019; 44:365-369   DOI
9 Heinzerling J.H., Anderson J.F., Papiez L., et al.: Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver. Int. J. Radiat. Oncol. Biol. Phys. 2008; 70:1571-8   DOI