• 제목/요약/키워드: variable discharge

검색결과 230건 처리시간 0.028초

반능동형 충격흡수기의 연속가변 감쇠특성에 대한 CFD 해석 (CFD Analysis on the Continuous and Variable Damping Characteristics of a Semi-Active Shock Absorber)

  • 윤준원
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.101-108
    • /
    • 2004
  • Recently, a semi-active shock absorber has been taking interest because of its low cost and simple structure than the active one. CFD analysis has been conducted to investigate the continuous and variable damping characteristics of the semi-active shock absorber. Also, the flow resistance characteristics of a spool valve has been examined to identify individual parameters(namely, exponent and discharge coefficient) of pressure-flow rate relation needed for the accurate valve modeling. The flow field in the damping valve was simulated using the commercial code, CFX-5.3. The numerical results showed reasonable agreement with the experimental outputs. The pressure distribution with the variation of spool opening length and volume flow rate were discussed in detail. And the continuous and variable damping performance was found clearly. The individual parameters of spool valve were obtained as a function of orifice area. The exponent and discharge coefficient were fitted in with the first and the third polynomial respectively.

가변전압 가변주파수(VVVF) 교류 플라즈마 전원장치 (AC Plasma Power Supply with Variable Voltage and Variable Frequency)

  • 신완호;윤기복;정환명;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1205-1207
    • /
    • 2004
  • AC plasma power supply is used to control a ozone generator and a air pollution gas. AC plasma power supply is composed of power semiconductor switch devices and control board adapted SHE(Selected Harmonic Elimination) PWM method. AC plasma power supply with sinusoidal VVVF(variable voltage and variable frequency) is realized. Its output voltage range is from 0 [V] to 20[kV] and output frequency range is from 8[kHz] to 20[kHz]. Using proposed system, AC high voltage and high frequency discharge is tested in the DBD(dieletric barrier discharge) reactor, and the space distribution of a its non-thermal plasma is observed. In spite of the increasement of voltage and frequency, the proposed system have a stable operation characteristics. It is verified by the experimental results.

  • PDF

가변속 왕복동형 압축기 본체의 동적 거동 해석 (Dynamic Behavior Analysis of a Reciprocating Compressor Body with Variable Rotating Speed)

  • 김태종
    • 한국소음진동공학회논문집
    • /
    • 제11권8호
    • /
    • pp.374-383
    • /
    • 2001
  • A reciprocating compressor unit with variable rotating speed driven by BLDC motor is mounted Inside hermetic chamber on an internal suspension composed of 4 roil springs and a discharge pipe. A method for predicting the dynamic behavior of compressor body is required for a reduction of transmitted vibrations. The mechanical characteristics of spring and discharge pipe stiffness properties have been obtained from experimental tests and mass moment of inertia of the compressor body iron CAD. To confirm the vibration model for the compressor body, free vibration analyses are performed with theoretical and experimental methods. results for analytical investigations on the dynamic behavior of the compressor body and the transmitted forces to the hermetic chamber through the suspension elements are Presented.

  • PDF

가변속 왕복동형 압축기 본체의 동적 거동 해석 (Dynamic Behavior Analysis of Reciprocating Compressor Frame with Variable Rotating Speed)

  • 김태종;이상민;박찬수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.362-367
    • /
    • 2001
  • A reciprocating compressor unit with variable rotating speed driven by BLDC motor is mounted inside hermetic chamber on an internal suspension composed of 4 coil springs and a discharge pipe. A method for predicting the dynamic behavior of compressor frame is required to reduce the transmitted vibration level. Mechanical characteristics such as mass, spring and discharge pipe stiffness properties are obtained with experimentation. To confirm the vibration model for compressor frame, free vibration analyses are performed with theoretical and experimental methods. Results for analytical and experimental investigations on dynamic behavior of the compressor frame are presented, and the agreement between measured and predicted results are satisfactory.

  • PDF

무작위 이송 개체용 실시간 동시 배출 알고리즘 개발 (Development of Real-time Simultaneous Discharge Algorithm for Randomly Feeding Object)

  • 김시찬;황헌
    • Journal of Biosystems Engineering
    • /
    • 제24권2호
    • /
    • pp.145-152
    • /
    • 1999
  • Methods of discharging each graded agricultural product are divided into two according to the type of feeding. One is based on feeding objects using a series of specially designed holders mounted with an equal interval. The other is randomly feeding objects while being isolated without a specific interval. In this paper, a real time simultaneous discharge algorithm, which is good for objects randomly fed individually and for multi-objects located along a series of discharge buckets, was developed. And the developed algorithm was implemented to the controller and the performance was verified using the system developed for dried mushrooms. The discharge system used for the experiment was composed of a variable speed conveyor, a series of double channel bucket mounted along both sides of the conveyor, and a series of air nozzles and optic sensors. Developed algorithm worked perfectly and could be directly used for automatic discharge system for randomly feeding agricultural products.

  • PDF

Reynolds Number를 변수로한 유동공기의 방전특성에 관한 연구 (Characteristics of Sparkover Discharge in Flowing Air with Reynolds Number's Variable)

  • 김영훈;이동인;이광식;김상구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.41-46
    • /
    • 1990
  • This paper shows the characteristics of sparkover discharge in flowing air ranging from O(Reynolds number, Re to 10.52$\times$104(Re). Also, we investigated changes of dis-charge pattern for constant input power by adjustment of the Re. The important results obtained from this paper are as followers. The maxinum sparkover voltage of flowing air are about 6.3[kV] higher than those of static air. The discharge pattern can be controlled by adjustment of the Re.

  • PDF

입제 비료의 변량 살포를 위한 제어기 개발 (Development of a Controller for Variable-rate Application of Granular Fertilizer)

  • 유지훈;김영주;류관희
    • Journal of Biosystems Engineering
    • /
    • 제31권2호
    • /
    • pp.108-114
    • /
    • 2006
  • This study was conducted to design and fabricate a controller for variable-rate application of granular fertilizer based on physical and chemical information, to analyze the performance of the controller and characteristics of a discharger. The result of the study are summarized as follows: 1. The charge ratios of discharger by accumulation heights of fertilizer in hopper were examined, and the variations in charge ratio were $72.58{\sim}93.33%$ and $63.14{\sim}94.42%$ for the fertilizers Super 21 and Sinsedae, respectively. The charge ratio also decreased as the rotational speed of discharger increased. 2. The coefficient of variation of discharge amount by rotational speed and discharge time of discharger were in the range of $2.94{\sim}11.23%$ and $2.82{\sim}10.80%$ for the fertilizer of Super 21 and Sinsedae. Except the rotational speed of 12 rpm, the coefficient of variation for discharge amount were relatively small with 4% more or less 3. In order to evaluate the rotational speed of discharger, the control signal in the range of $0{\sim}5V$ was subdivided into the 50 steps by 0.1V. The regression equation for the rotational speed of discharger was Y=55.984X-79.174(X: input voltage, V, Y: discharger speed, RPM) and the $R^2$ was 0.99. 4. In order to evaluate the performance of the controller for variable-rate application of granular fertilizer, settling time to unit step input was examined. The settling time varied from 0.8sec to 1.4 sec.

Comparison of Classification Rate for PD Sources using Different Classification Schemes

  • Park Seong-Hee;Lim Kee-Joe;Kang Seong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.257-262
    • /
    • 2006
  • Insulation failure in an electrical utility depends on the continuous stress imposed upon it. Monitoring of the insulation condition is a significant issue for safe operation of the electrical power system. In this paper, comparison of recognition rate variable classification scheme of PD (partial discharge) sources that occur within an electrical utility are studied. To acquire PD data, five defective models are made, that is, air discharge, void discharge and three types of treeinging discharge. Furthermore, these statistical distributions are applied to classify PD sources as the input data for the classification tools. ANFIS shows the highest rate, the value of which is 99% and PCA-LDA and ANFIS are superior to BP in regards to other matters.

수문학적 모의기법에 대한 연구 - 낙동강 왜관지점의 연유량과 월유량의 모의발생 및 비교 - (A Study of the hydrological generation - The generation and comparison with annual and monthly dicharge at Wacgwan in the Nakdong River)

  • 천덕진;최영박
    • 물과 미래
    • /
    • 제13권1호
    • /
    • pp.49-56
    • /
    • 1980
  • The thesis of this analytical study includes 1) the generation of annual and monthly discharge regarding single hydrological variable at single site, 2)comparsion with the historical records and the generation, and 3) changing the monthly generatied discharge into annual. The conclusion of this will be used for the future plan for water resources development. Annual discharges at waegwan are characterized by log-normal distirbution and persistence-absent. Also, the random number generator causes the errors in the generation of annual discharge. The serial correlation coefficients of the generated annual discharge have less value than that of historical records, while the correlation coefficient and slope in January have(+) value and opposite to historical record. To change the monthly generated discharge into annual is not proper.

  • PDF

친환경 정밀농업을 위한 입제 변량살포기 개발 (II) -송풍식 붐형 분두 개발과 살포균등도 - (Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (II) - Development of Pneumatic Fertilizer Blow Head and Its Application Uniformity -)

  • 김영주;김학진;서민;이중용
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.474-481
    • /
    • 2006
  • In this paper, a new type blow head was developed and pneumatic application system was evaluated. The blow head had one operating factor, inserting length of collecting plate, that was directly related to discharge rate and application pattern. To determine Proper blow head arrangement and application height, a blow head set was tested. Three-way ANOVA was conducted to investigate relationships between CV value, the discharge rate and inserting length of collecting plate. The discharge rate and inserting length of collecting plate were statistically significant at p=0.01, affecting uniformity of application pattern. The best CV value among the application tests was 23.3% when the application rate and application height was 23.5 g/sec and 80 cm respectively. The worst CV value was 63.3% in 111.4 g/sec. Therefore, it is necessary to increase number of blow head in a section of the boom in improve application uniformity.