• Title/Summary/Keyword: vane pump

Search Result 142, Processing Time 0.022 seconds

Improvement of Performance Instability and Miniaturization of Very Low Specific Speed Centrifugal Pump (극저비속도 원심펌프의 불안정성능개선 및 소형화에 관한 연구)

  • Choi, Young-Do;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.21-28
    • /
    • 2007
  • The ratio of disk friction loss in a centrifugal pump is very large for the total pump loss in the range of very low specific speed. Therefore, impeller radius should be shortened to increase the pump efficiency because the disk friction loss is proportional to the fifth power of impeller radius. In order to compensate the decreased head by the shortened impeller radius, vane angle at impeller outlet should be increased. However, as the vane angle at impeller outlet becomes larger, performance instability occurs at low flow rate regions. In this study, J-Groove is adopted to suppress the performance instability and detailed examination is performed for the influence of the J-Groove on the pump performance. The results show that J-Groove gives good effect on the suppression of performance instability. Moreover, as J-Groove increases pump head considerably, the pump size can be smaller for head requirements.

A Study on Flow Characteristics and Efficiency in Guide Vane of Diffuser Pump Using PIV Measurement (PIV를 이용한 디퓨저펌프 정익에서의 성능과 유동특성에 관한 연구)

  • 김정환;김범석;김진구;함승덕;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.633-640
    • /
    • 2003
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation Identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

A Study on Flow and Efficiency Characteristics in Guide Vane of Diffuser Pump Using PIV Measurement (PIV 계측을 이용한 디퓨져펌프의 정익에서의 성능과 유동특성에 관한 연구)

  • Kim, J. H.;Choi, M. S.;Kim, J. G.;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.29-35
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

Flow Characteristics of Guide Vane of Diffuser Pump by PIV Measurement (PIV계측에 의한 디퓨져펌프 안내깃에서의 유동특성)

  • Kim, J.H.;Choi, J.W.;Kim, M.Y.;Lee, H.;Lee, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.391-396
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within a diffuser pump. Various different kinds of clearance were selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors was implemented with direct calculation of correlation coefficients. Fine optical setup important in PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Various flow patterns are represented quantitatively at the stator passages.

  • PDF

A PIV Measurement on Flow Characteristics inner Diffuser Pump Using High Resolution CCD Camera (고해상도 CCD 카메라를 이용한 디퓨져펌프 내부 유동특성에 대한 PIV 계측)

  • 김성윤;김범석;김정환;김유택;이영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.161-166
    • /
    • 2002
  • The resent experimental study is focused on the application of multi-point simultaneous measurement by PIV Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational veto ity and changing clearance between Guide Vane and Impeller were selected as experimental condition. Optimized ross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coeffi cients. Fine optical setup concerned with PW performance is arranged for the accurate PW measurement of high peed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

Design of Impeller and Diffuser for Mixed Flow Pump with Inverse Design Method (역설계 방법을 적용한 사류펌프의 임펠러 및 디퓨저 설계)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Kim, Jun-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1322-1325
    • /
    • 2009
  • The impeller and vane diffuser for the mixed flow pump(NS550) was designed by using meridional selection program and inverse design method. We decided the meridional shape of the impeller from the meridional design parameter, such as the specific speed and maximum diameter at the impeller exit. The meridional shape of vane diffuser was set from the impeller shape, distribution of cross sectional area and maximum diffuser diameter. The angle of impeller blade and diffuser vane was designed by using inverse design method. The predicted overall performance by using commercial CFD code(ANSYS CFX-11) shown good agreement with design goals.

  • PDF

The Analytical Study on the Pressure Ripples in a Positive Displacement Vane Pump (유압 베인 펌프의 압력 맥동에 관한 연구)

  • 김기동;조명래;한동철;최상현
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.225-231
    • /
    • 1997
  • This paper reports on the theoretical study of the delivery pressure ripples of a positive displacement vane pump which is widely used for automobile power steering. Pressure ripples occur due to the flow tipples which induced cam ring profiles and reverse flow from the delivery ports. In this paper, the mathematical model for analyzing the pressure ripples has been presented, and set of the differential equationshave been solved using the Runge-Kutta method. As the results of analysis, instant ideal flow ripples, internal pressure, delivery pressure ripples, and delivery flow ripples have been presented. Internal pressure was related to delivery pressure variations, and amplitude of pressure tipples was increased with rotational speed and delivery pressure.

  • PDF

A Study on the Improvement of Lubrication Characteristics for Fuel Pump in LPG Engine (자동차용 LPG 연료펌프의 윤활성 개선에 관한 연구)

  • Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong;Park, Cheol-Woong
    • Journal of ILASS-Korea
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In recent years, the need for more fuel-efficient and lower-emission vehicles has driven the technical development of alternative fuels such as LPG (Liquefied Petroleum Gas) which is able to meet the limits of better emission levels without many modifications to current engine design. LPG has a high vapor pressure and lower viscosity and surface tension than diesel and gasoline fuels. These different fuel characteristics make it difficult to directly apply the conventional gasoline or diesel fuel pump. Self acting lubricated groove design or coating can be used in high-speed and high precision spindle system like a roller-vane type fuel pump, because of its advantages such as low frictional loss, low heat generation, averaging effect leading better running accuracy and simplicity in manufacturing. Those design method can also affect the atomization of fuel from the injector and the formation of fuel film on the intake manifold. In this study, experiments are carried out to get performance characteristics of initial and steady state operation, The characteristics of vane type fuel pump were investigated to access the applicability on LPLi engine.

Blade Shape Design of Mixed-flow Pump Impellers and Diffusers in a Fixed Meridional Geometry (자오면 고정 형상에서 사류펌프 임펠러 및 디퓨져 날개형상 설계)

  • Kim, Sung;Choi, Young-Seok;Lee, Kyoung-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1203-1208
    • /
    • 2009
  • In this paper, the flow characteristics of the mixed-flow pump impellers and diffusers were numerically predicted by commercial CFD software and DOE(design of experiments). We also discussed how to improve the performance of the mixed-flow pump by designing the impeller and diffuser in the mixed-flow pump. Geometric design variables were defined by the vane plane development which indicates the blade-angle distributions and length of the impeller and the diffusers. Firstly, the design optimization of the defined impeller geometric variables has been done. After that, the flow characteristics were analyzed in the point of incidence angle at the diffuser leading edge for the optimized impeller. Then design of the defined diffuser shape variables has been performed. The reason for the performance improvement was discussed by examining the flow characteristics through the diffuser.

  • PDF

3 Dimensional Flow Analysis of Small Regenerative Pump (소형 재생펌프의 3차원 성능 해석에 관한 연구)

  • Kang, Shin-Hyoung;Lim, Hyung-Soo;Ryu, Su-Hyun;Shim, Chang-Yeul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1600-1607
    • /
    • 2004
  • Performance of a regenerative pump is evaluated based on the calculated through flows using the CFX-TASCflow code. Flow calculations are performed in one vane to vane space of the impeller and side channel. The flow is very complex three dimensional with a strong radial vortex due to centrifugal force and an axial vortex due to re-circulating flow between the impeller and the side channel. Momentum exchange on the plane between the impeller and the side channel are evaluated to estimate design parameters and viscous losses in the pump. The present study contributes to showing the capability of flow simulation of complex flow in the regenerative pump by comparing the calculated performance with the measured value.