Automated Visual Inspection System of Double Gear using Inspection System (더블기어 자동 시각 검사 시스템 실계 및 구현)

  • Lee, Young Kyo;Kim, Young Po
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.4
    • /
    • pp.81-88
    • /
    • 2011
  • Mini Double Gears Frame is critical part of PDP and also produces couple hundred thousand every month. In the process of mass production, product inspection is very important process. Double Gear, one of the part of machine, was inspected by human eyes which caused mistakes and slow progress. To achieve the speed and accuracy the system was compensated by vision system which is inspecting automatically. The focus value is measured based on the fact that high contrast images have much high frequency edge information. High frequency term of the image is extracted using the high-pass filter and the sum of the high frequency term is used as the focus value. We used a Gaussian smoothing filter to reduce the noise and then measures the focus value using the modified Laplacian filter called a Sum modified Laplacian Focus values for the various lens positions are calculated and the position with the maximum focus value is decided as the focused position. The focus values calculated in various lens position showed the Gaussian distribution. We proposed a method to estimate the best focus position using the Gaussian curve fitting. Focus values of the uniform interval lens positions are calculated and the values are used to estimate the Gaussian distribution parameters to find the best focus position.

A Technique Study for Improve the Precise Position Stopping of Automatic Train Operation (ATO) Train Vehicle in Urban Railway (도시철도 자동운전 차량의 정밀정차 향상을 위한 기법 연구)

  • Ma, Sang-Kyeon;Heo, Dae-Jeung;Kim, Myung-Hwan;Song, Jae-Cheong;Park, Jun-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1049-1058
    • /
    • 2011
  • This paper suggests blending time adjusting method of braking command characteristics management and Set value test for optimizing of braking deceleration to enhance the precise position stopping. This method minimizes pneumatic-braking degree deviation by characteristics management, and secures braking stability at braking. By Set value test method, braking blending characteristics are analyzed accurately. And by optimal timing tuning at braking blending, It enhanced the precise position stopping with stabilization of deceleration To demonstrate the usefulness of these suggestion, I modeled for Deajeon Line #1. And through comparison with case of related companies, the proposed method which this paper suggested is proved to be superior to others.

  • PDF

Effect of root gaps on toughness of FCAW weld metal (FCAW 용접부의 인성에 미치는 Root Gap의 영향)

  • 한종만;이은배;안성철;한용섭
    • Journal of Welding and Joining
    • /
    • v.9 no.4
    • /
    • pp.40-49
    • /
    • 1991
  • Both impact and fracture toughnesses were investigated with root gaps in FCAW weld metals at room temperature and 0.deg.C. The maximum impact value was obtained at the root gap of 16mm for 1G position weld metal, and the impact value of 3G position weld metals also showed the maximum impact value at the root gap of 12mm. However, the fracture toughnes(CTOD)values tend to decrease with increasing root gaps at both temperatures in 1G weld metal. Bending test also showed satisfactory results with all of root gaps investigated. Based on this result, it becomes possible to apply wide root gaps in real projects in both aspects of toughness and bending resistance.

  • PDF

A Study of Selective Indoor Positioning between Enhanced Time Difference of Arrival and Pattern Matching using Received Signal Strength Indicator (RSSI를 이용한 향상된 TDOA와 Pattern Matching 간의 선택적 실내 측위에 관한 연구)

  • Hur, Soo-Jung;Kim, Jea-Hyun;Park, Yongwan
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2013
  • This paper researches location estimating method in CDMA system. Previously proposed positioning algorithms are difficult to estimate accurate position in indoor environments, and possible to limited position. This paper proposes enhanced algorithm using received PN pilot signals from base stations to enhance previous algorithms. For estimating position, we set the threshold value and use over the threshold value in received signals. After selecting signals, we estimate position using TDOA algorithm. And the cases which TDOA algorithm cannot use to estimate position, we use Pattern Matching algorithm. The proposed method system showed the improved performance in estimating parameters and locating positions by computer simulations.

Position estimation using combined vision and acceleration measurement

  • Nam, Yoonsu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.187-192
    • /
    • 1992
  • There are several potential error sources that can affect the estimation of the position of an object using combined vision and acceleration measurements. Two of the major sources, accelerometer dynamics and random noise in both sensor outputs, are considered. Using a second-order model, the errors introduced by the accelerometer dynamics are reduced by the smaller value of damping ratio and larger value of natural frequency. A Kalman filter approach was developed to minimize the influence of random errors on the position estimate. Experimental results for the end-point movement of a flexible beam confirmed the efficacy of the Kalman filter algorithm.

  • PDF

Construction of the 2D General $\Delta-TABLE$ of the Numerical Series of Position for the Syntactical Semantics of Visual Space (시(視)공간의 통사의미론을 위한 위치수열 2차원 일반 $\Delta-TABLE$의 구성)

  • Kim Bok-Young
    • Journal of Science of Art and Design
    • /
    • v.2
    • /
    • pp.239-293
    • /
    • 2000
  • The paper aims to study how to describe the rigorous position on which semantic elements are laid, within the visual space. This purpose is, first of all, for the construction of visual syntactical semantics of the visual space. For this aim, the preliminary research begins with some definitions on : 1) visual space, visual design, visual syntactical semantic meaning, 2) position, sequence of position, 2-dim. sequence of position, and 3) 2-dim. numerical series of position, harmonious dynamic values. Here, The main issue is to define the position in general. To solve this problem, the researcher surveyed the positions on which the sets of pixemes are set up. The results are as follows ; 1. As far as the positions in visual space are concerned, they are the possible locations permitted in the visual patches. They are not the factual but the possible positions. 2.The position value that the sequential point has is not arithmetical but harmonious-dynamic, for it is not permitted for its own sake, but for the person, that is to say, for the viewer's visual perception. 3. The harmonious-dynamic value of positional sequence can be composed of the 2-dimensional successive numerical series which is, in turn, composed of the primordial 3 values x0, $\mu0$, y0. Here, the $\mu0$ is the harmonious mean value of x0 and y0. The x0 and y0 are, therefore, of the mutual dynamic relationship. 4. From this, the 2-dim general $\Delta-TABLE$ of the numerical series of position in visual design could be acquired through development of the primordial 3 values into the $X_i,\;Y_i$, orbit values.

  • PDF

Position Value for Relative Comparison of Healthcare Status of Korea in 2018 (2018년 한국 보건의료의 상대적 위치와 추이: 경제협력개발기구 국가와 비교)

  • Youn, Hin Moi;Lee, Hyeon Ji;Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.31 no.2
    • /
    • pp.217-224
    • /
    • 2021
  • The objective of this study is to investigate the healthcare status of South Korea and other member countries of the Organization for Economic Cooperation and Development (OECD) using OECD health statistics 2020. We employed the position value for relative comparison index to measure the healthcare status in five following components: demand, supply, accessibility, quality, and cost. The Mann-Kendall test was used to analyze for increasing or decreasing trend of the position value for relative comparison values from 2000 to the recent year. Results showed that Korea was positioned above than the OECD median values in most of components, but lower than the median values in certain indices including healthcare employment, primary care, and mental health care. This study sheds some light on healthcare issues to be improved and the policy-makes can take into account for prior setting process.

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF

A Study on the Sensor Calibration of Motion Capture System using PSD Sensor to Improve the Accuracy (PSD 센서를 이용한 모션캡쳐센서의 정밀도 향상을 위한 보정에 관한 연구)

  • Choi, Hun-Il;Jo, Yong-Jun;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.583-585
    • /
    • 2004
  • In this paper we will deal with a calibration method for low cost motion capture system using psd(position sensitive detection) optical sensor. To measure the incident direction of the light from LED emitted marker, the PSD is used the output current ratio on the electrode of PSD is proportional with the incident position of the light focused by lens. In order to defect the direction of the light, the current output is converted into digital voltage value by opamp circuits peak detector and AD converter with the digital value the incident position is measured. Unfortunately, due to the non-linearly problem of the circuit poor position accuracy is shown. To overcome such problems, we compensated the non-linearly by using least-square fitting method. After compensated the non-linearly in the circuit, the system showed more enhanced position accuracy.

  • PDF

Position Error Compensation Method of Hall Sensors for Sunroof System using BLDC Motor (선루프용 BLDC 전동기 홀센서 위치 오차 보상 기법)

  • An, Jeong-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.53-57
    • /
    • 2017
  • This papers propose a Hall-effect sensors position error compensation method in a sunroof system using a BLDC motor with a low-cost MCU. If the BLDC motor is controlled with this wrong position, the torque ripple and operating current can be increased and the average torque also decreases. Generally, sunroof system has characteristics that operate at constant load for several seconds. It is possible to find the minimum operating current value while changing the position of the Hall-effect sensor during the sunroof operation by using these characteristics. Therefore, propose a method to change the Hall-effect sensor position and find the minimum current value. The validity of the proposed algorithm is verified through experiments.