• Title/Summary/Keyword: value measurement

Search Result 4,742, Processing Time 0.029 seconds

Studies on the Effect of the Heavy Metals and CN on the $BOD_{5}$ Measurement (중금속 및 CN이 $BOD_{5}$ 측정에 미치는 영향)

  • 어수미;박성배
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.74-78
    • /
    • 1991
  • This study was performed to investigate the effect of heavy metals and CN on BOD$_{5}$ measurement. The results were as follows: 1. The BOD$_{5}$ value decreased 20% in Cd(CdCl$_{2}$) 3.0mg/l, Ni(NiCl$_{2}$) 7.0mg/l, Cu(CuCl$_{2}$) 0.5mg/l, Pb($Pb(NO_{3})_{2}$) 9.0mg/l, Cr($K_{2}Cr_{2}O_{7}$) 1.0mg/l respectively. 2. The BOD$_{5}$ value decreased 10% in Zn($Zn(NO_{3})_{2}$) 5 mg/l, Fe(FeCl$_{3}$) 20mg, /l, and 25% in CN(KCN) 5mg/l, and 40% in Hg(HgCl$_{2}$) 0.2rng/l. 3. In Comparion with BOD Rapid Analyzer, the above mentioned heavy metals concentrations have no effect on BOD$_{5}$ value of that analyzer except CN.

  • PDF

Development in Equipment of Low Point Marking Machine Control System (Low Point 모니터링 장비의 개발)

  • Choi, Myung-Hwan;Kim, Won-Il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.4
    • /
    • pp.205-209
    • /
    • 2010
  • Even the domestically small-and medium-sized companies progressed development in the monitoring equipment of inspecting run out in steel wheel aiming to supply and generalize through developing the monitoring equipment for securing quality technology and enhancing quality-test level. Run-Out value in vehicle wheel was measured with Computer & Servo system by using Low-Point marking machine control system, which is this development product. Low-Point value was operated and calculated. It marked by revolving wheel as much as the demanded measurement value based on 1ST harmony curve. Thus, the shipment of inferior product, which occurs in the measurement by the existing worker, could be blocked in advance. In the existing case, 60 sec. was required for inspecting 1 product. However, it came to bring about a rise in production volume through shortening inspection time to 8 seconds and improving workers' operating environment.

  • PDF

Evaluation Technique of Burden for Current Transformer using Current Transformer Comparator and Precise Shunt Resistor (전류변성기 비교기와 정밀션트저항을 이용한 전류변성기용 부담의 평가기술)

  • Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.250-256
    • /
    • 2006
  • Both ratio error and phase angle error in current transformer(CT) depend critically on values of CT burden. Thus, precise measurement of CT burden is very important for the evaluation of CT. A method for the measurement of CT burden has been developed by employing the portable shunt precise resistor with negligible AC-DC resistance difference less than $10^{-5}$. The burden value(value and power factor) can be calculated from resistance and reactance obtained by measuring the change of ratio error and phase angle error caused by the change of shunt resistor. The uncertainty for the method is evaluated and found to be abut 2 %.

Inductance Characteristics of Tokamak Poroidal Field Coil by the Plasma Current (Plasma Current에 의한 Tokamak Poroidal Field Coil의 Inductance 특성)

  • Chung, Yoon-Do;Lee, Seung-Je;Kim, Tae-Joong;Kim, Kee-Man;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.801-803
    • /
    • 2000
  • The large scale magnets like thermalnuclear fusion devices are necessary for superconducting CICC cable, When the Cable In Conduit Conductors(CICC) is occurred by the external turbulence, the CICC occurs to quench, The CICC can be broken because the CICC spends all energy in the quench-happened spot. Therefore, it is necessary to develop measurement systems of the quench detection. The measurement systems of the relative good degree of efficiency are the voltage tap sensors. The weak points of voltage tap sensors are effected by EMF noise and inductance. The thermalnuclear fusion devices easily can't measure inductance value because of plasma current. In the experiment, The value of inductance was estimated by FEM techniques and the decrement of Inductance value measured as long as remaining plasma current.

  • PDF

A Study on the Realization of Variable Spatial Filtering Detector with Multi-Value Weighting Function (계측용 공간필터의 가변적 다치화된 가중치 실현에 관한 연구)

  • Jeong, Jun-Ik;Han, Young-Bae;Go, Hyun-Min;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.481-483
    • /
    • 1998
  • In general, spatial filtering method was proposed to simplify measurement system through parallel Processing hardware. Spatial filtering is a method of detection that we can get a spatial pattern information, as we process a special space pattern, to say, as we process spatial parallel process by using the spatial weighting function. The important processing characteristics will be depended in according to how ire design a spatial weighting function, a spatial sensitive distribution. The form of the weighting function which is realized from the generally used spatial filtering is fixed and the weighting value was already became a binary-value. In this paper, we propose a new method in order to construct adaptive measurement systems. This method is a weighting function design to make multi-valued and variable.

  • PDF

Implemented of non-destructive intelligent fruit Brix(sugar content) automatic measurement system (비파괴 지능형 과일 당도 자동 측정 시스템 구현)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.433-439
    • /
    • 2020
  • Recently, the need for IoT-based intelligent systems is increasing in various fields. In this study, we implemented the system that automatically measures the sugar content of fruits without damage to fruit's marketability using near-infrared radiation and machine learning. The spectrums were measured several times by passing a broadband near-infrared light through a fruit, and the average value for them was used as the input raw data of the machine-learned DNN(Deep Neural Network). Using this system, he sugar content value of fruits could be predicted within 5 s, and the prediction accuracy was about 93.86%. The proposed non-destructive sugar content measurement system can predict a relatively accurate sugar content value within a short period of time, so it is considered to have sufficient potential for practical use.

A Study on the Optimal Frequency for Precise Measurement of Fracture Velocity by Ultrasonic Fractography (초음파 Fractography에 의한 파괴속도의 첨밀측정을 위한 최적주파수 선정에 관한 연구)

  • Lee, B.S.;Han, E.K.;Song, C.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.154-160
    • /
    • 1993
  • A mothod to decide the optimal frequency for the fracture velocity measurement by ultrasonic fractography is presented. A theoretical formula to decide the optimal frequency for ultrasonic fractography testing is made and it is compared with experimental value. According to the formula the optimal frequency is shown to be depending on the attenuation coefficient and size(width) of the specimen. In the case of PMA specimen with ligament 43mm the theoretical value for the optimal frequency is about 260 KHz and it is good agreement with experimental value.

  • PDF

The Study on effect of the Muscle Activities for Dietshoes (Backless) (다이어트신발(Barkless)이 근육 활성도에 미치는 영향에 관한 연구)

  • Lee, Chang-Min;Oh, Yeon-Ju;Lee, Kyung-Deuk;Park, Seung-Bum;Lee, Hoon-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.117-124
    • /
    • 2006
  • The modern convenient life formed by industrial development becomes lack of exercise and takes an interest in diet. Specially, professional walking shoes is developed as people take an interest in jogging, Those shoes, professional walking shoes or Dietshoes, increase exercise effects by change of heel types. Therefore, this study investigated motility effects by EMG experiment in order to measure Muscle Activities (MA) while wearing diet shoes (backless). Experiment was conducted by EMG measurement, from calf (gastrocnemius muscle), thigh (vastus muscle) and waist (erector spinae muscle), of 12 high school students. Exercise effects between the two shoes were analyzed by EMG (MF; Median Frequency, MPF; Mean Power Frequency, ZCR; Zero Crossing Rate). Results showed that the Dietshoes(MF: 48.21Hz, MPF: 65.0Hz, ZCR: 100.6Hz) had larger EMG value than that of Normal shoes(MF: 40.47Hz, MPF: 58.04Hz, ZCR: 82.09Hz). Also, in MA, the highest activities are showed in the calf, the second one is in waist, and last one is in thigh during gate. ANOVA between shoes in measurement parts showed significant effects in MF (gastrocnemius: p-value=.022, vastus laterals: p-value=.037, erector spinae: p-value=.082), MPF (gastrocnemius: p-value=.032, vastus laterals: p-value=.046, erector spinae: p-value=.090), and ZCR (gastrocnemius: p-value=.000, vastus laterals: p-value=.004, erector spinae: p-value=.134). And MA of Dietshoes is higher than that of Normal shoes, and decreasing rate of MA in Dietshoes is less than that of Normal shoes. Thus, this study validates exercise effects of Dietshoes.

A Study on TTX Traction Characteristics using Measurement System (계측시스템을 활용한 틸팅열차 추진장치 특성 연구)

  • Han, Young-Jae;Lee, Su-Gil;Park, Choon-Soo;Han, Seong-Ho;Lee, Jun-Seok;Jung, Kwon-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1093-1098
    • /
    • 2007
  • Tilting trains are currently in operation in 13 countries around the world. With the advances in tilting technology, verification of economic efficiency, and changes in economic situations, the introduction of tilting trains will rapidly spread across the globe. The measurement system is composed of the industrial computers installed in the console and the measurement racks mounted on each car. It is utilized to accumulate the data by the communication card and the optical cable. The optical cable and power cable are coupled at the connector located in joint of train to make easy to disconnect car each other. The signal conditioner is designed to choose and to extend the channel for each sensor readily. The sensor measurement rack has adopted as decentralization method. It is installed in each car to minimize the cable length. In also, it is manufactured based on 19"rack and covered to protect the cable. In this study, the programs for measurement and analysis were also developed to understand the traction system characteristics of TTX. Using this measurement system, we studied that acceleration test, re-powering test, and gradually powering test. The acceleration performance of TTX is 1.735 km/h/s, and it is inner standard value. The notch test result from 1 to 7 steps, DC link voltage is under standard value, and the output electric current of inverter is controlled normally. From the test results, we saw the performances of the traction systems are normal.

The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester (MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템)

  • Ra-Yun Boo;Jung-Hun Choi;Myung-Eui Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.203-208
    • /
    • 2023
  • In this study, we propose a method to improve the precision of contact resistance measurement circuits using constant current method and voltage drop method, and implement a dashboard that monitors the measured data of contact resistance measurement systems through MQTT broker server. The contact resistance measurement system measures the resistance value and transmits the measured value to the MQTT broker server using wireless communications. This developed dashboard uses Node-RED and Node-RED-Dashboard to receive the resistance values of up to four contact resistance measurement systems and show them to user's monitor screen. Users can manage multiple measurement data using a single dashboard and easily interface with other devices through the MQTT broker server. Through the experimental results from real data measurements, the relative standard deviation about precision is improved to average 40.37% and maximum 64.73% respectively.