• Title/Summary/Keyword: value measurement

Search Result 4,742, Processing Time 0.039 seconds

An Effective Selection of white Gaussian Noise Sub-band using Singular Value Decomposition (특이값 분해를 이용한 효율적인 백색가우시안 잡음대역 선정 방법)

  • Shin, Seung-Min;Kim, Young-Soo;Kim, Sang-Tae;Suk, Mi-Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.3A
    • /
    • pp.272-280
    • /
    • 2009
  • Measurement of the background radio noise is very important process being used in survey of radio noise environment, calculating the threshold level for the frequency occupancy measurement and so forth. First step of background radio noise measurement is to select the sample sub-band which is mostly dominated by the background white Gaussian noise (WGN) within the target band. The second step is to carry out the main measurement of radio noise on this selected sample sub-band for the representative value of the noise power. In this paper, a method for selection of sample sub-band for the effective background radio noise measurement using SVD is proposed under the assumption that background radio noise is WGN. The performance of the proposed method is compared with that of the APD method which is widely used for the same purpose. Simulation results are shown to demonstrate the high performance of the proposed method in comparison with the existing APD method.

Measurement of Rail Irregularity using acceleration values acquired from the High Speed Rolling stock 350 experimental (HSR-350x) (한국형고속열차의 가속도계를 이용한 궤도 불규칙도 검측)

  • Kim, Young-Mo;Kim, Jin-Woo;Park, Chan-Kyoung;Park, Tae-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1264-1269
    • /
    • 2006
  • Measurement and estimation of rail irregularity is an important factor to concern travelling safety of train. Now a day, rail irregularity have been measured by EM120 and ROGER 1000K imported from MERMAC Co. Italy and making researches actively in Korea. This paper mainly consider to find correlation between acceleration value of wheel axle in HSR350x and rail irregularity value measured by EM120.

  • PDF

Determination Conversion Weight of Convertible Bonds Using Mean/Value-at-Risk Optimization Models (평균/VaR 최적화 모형에 의한 전환사채 주식전환 비중 결정)

  • Park, Koohyun
    • Korean Management Science Review
    • /
    • v.30 no.3
    • /
    • pp.55-70
    • /
    • 2013
  • In this study we suggested two optimization models to determine conversion weight of convertible bonds. The problem of this study is same as that of Park and Shim [1]. But this study used Value-at-Risk (VaR) for risk measurement instead of CVaR, Conditional-Value-at-Risk. In comparison with conventional Markowitz portfolio models, which use the variance of return, our models used VaR. In 1996, Basel Committee on Banking Supervision recommended VaR for portfolio risk measurement. But there are difficulties in solving optimization models including VaR. Benati and Rizzi [5] proved NP-hardness of general portfolio optimization problems including VaR. We adopted their approach. But we developed efficient algorithms with time complexity O(nlogn) or less for our models. We applied examples of our models to the convertible bond issued by a semiconductor company Hynix.

Model design for quantitative value measurement of individual technologies -R&D performance measurement and technology transaction- (개별기술의 정량적 가치추정 모델개발;연구개발투자의 성과측정 및 기술거래시 활용을 중심으로)

  • 조현춘
    • Journal of Korea Technology Innovation Society
    • /
    • v.3 no.1
    • /
    • pp.139-153
    • /
    • 2000
  • The aim of this paper is to provide a new model to evaluate the quantitative value of technology(nonfinancial benefits). This new model is based on the technology stock(technology level) ac-quired in R&D process. The model can explain the quantitative relation between the technology stock(level) and the market value of technology as considering the R&D expenditure to acquire technologies above a certain level(>70%) in comparison with the advanced country and the cost to prevent the technology obsolescence. The value of non-destructive testing technology which is one of the electric power technology is measured quantitatively as a case study.

  • PDF

Performance Measurement Method for Efficient Value Engineering Study of Railroad Construction Project (철도건설사업의 효율적인 VE수행을 위한 성능측정기법)

  • Lim, Jong-Kwon;Park, Mi-Yun;Park, Heung-Min;Kim, Sung-Hun;Lee, Kwang-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2242-2249
    • /
    • 2008
  • A severe problem in VE study of a project is to reduce value due to loss of performance, caused by focusing on cost reduction. Also a lack of understanding performance concept, no trial VE workshop as well as cost saving-based policy have not satisfied customer needs. A efficient VE job plan for especially large scale railroad construction project is proposed in this study. This study developed a more objective performance evaluation system for value engineering study of mega projects and suggested a systematic process of performance quantitative analysis for value improvement. The proposed performance measurement method would be very useful for better communication and consensus between decision makers and VE team.

  • PDF

The Critical Current Characteristics and n-value Measurement of HTS Tapes (HTS선재의 $I_c$-B 특성 및 n 값 측정)

  • Ku, Myung-Hwan;Kang, Myung-Hun;Lee, Hee-Joon;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.12-16
    • /
    • 2010
  • Critical current - magnetic field ($I_c$-B) relation is one of the basic properties of an HTS wire, which is needed for the design of performances of superconducting devices. Experimental results of the $I_c$-B relation of Bi-2223 and YBCO superconducting wire are presented in this paper. n-value is also an important parameter which is needed to calculate the electric field by using the power-law. Measurement results of the n-value of the same HTS superconducting wires are also presented.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

A study on the detection threshold for multitarget tracking (다중표적 추적을 위한 표적 탐지 임계값에 대한 연구)

  • 이양원;이봉기;김광태;김경기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.834-838
    • /
    • 1992
  • Tracking performance depends on the quantity of the measurement data. In the Kalman-Bucy filter and other trackers, this dependence is well understood in terms of the measurement noise covariance matrix, which specifies the uncertainty in the value of measurement inputs. In this paper, we derived approximated error covariance matrix to evaluate the dependence of target detection probability and false alarm probability in the presence of uncertainty of measurement origin.

  • PDF

Application of Rotating Polarizer Method to Low LC Cell Gap Measurement

  • Kim, Chang-Son;Lee, Gi-Dong;Yoon, Tae-Hoon;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.199-200
    • /
    • 2000
  • Measurement of low cell gap and retardation by using a rotating polarizer method was proposed. For more precise calculation and measurement, we applied a retardation film that has large retardation value of $1\;{\mu}m$ to measurement system. From experiments, we proved that cell gap and retardation could be measured even though the values of those are so small.

  • PDF