• Title/Summary/Keyword: value gap

Search Result 1,039, Processing Time 0.027 seconds

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

Reduction Gas and Chemical Additive Effects on the MOCVD Copper Films Deposited From (hfac)Cu(1,5-DMCOD) as a Precursor ((hfac)Cu(1,5-DMCOD) 전구체를 이용한 MOCVD Cu 증착 특성에 미치는 환원기체와 첨가제의 영향에 관한 연구)

  • Byeon, In-Jae;Seo, Beom-Seok;Yang, Hui-Jeong;Lee, Won-Hui;Lee, Jae-Gap
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2001
  • The deposition characteristics of MOCVO Cu using the (hfac)Cu(I) (1,5-DMCOD)(1,1,1,5,5,5-hexafluoro-2,4-pentanedionato Cu(I) 1,5-dimethyl-cyclooctadine) as a precursor have been investigated in terms of the effects of hydrogen and H(hfac) ligand addition with He carrier gas. MOCVD Cu using a Helium carrier gas showed a low deposition rate (20~$125{\AA}/min$) at the substrate temperature range of 180~$230^{\circ}C$. Moreover, the Cu film deposited at 19$0^{\circ}C$ was very thin (~$700{\AA}$) and showed the lowest resistivity value of $2.8{\mu}{\Omega}-cm$. The deposition rate of MOCVD Cu using $H_2$or H(hfac) addition was significantly enhanced especially at the low temperature region (180~$190^{\circ}C$). Furthermore, thinner Cu films (~$500{\AA}$) provided low resistivity (3.6~$2.86{\mu}{\Omega}-cm$). From surface reflectance measurement, very thin films deposited by using different gas system revealed good surface morphology comparable with sputtered Cu film ($300^{\circ}C$, vacuum-anneal). Hence, Cu film using (hfac)Cu(1,5-DMCOD) as a precursor is expected as a good seed layer in the electrochemical deposition process for Cu metallization.

  • PDF

Effects of Aggregate Grading on the Performance of High-Flowing Concrete with General Strength (일반 강도용 고유동 콘크리트에서의 골재 입도 영향)

  • Kim, Sang Chel;Kim, Yun Tae;Shin, Dong Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.63-72
    • /
    • 2012
  • The high-flowing concrete requires additionally or excessively more expensive admixture than conventional concrete. So, the concrete has not to be widely used in practical field due to the increase of production price, need of additional facilities, and excessive development of concrete strength in associate with addition of too much cementitious material even though it has more significant advantages than conventional concrete. Thus, this study aims at developing high-flowing concrete with general strength unlike high strength which has been carried out in conventional study. To observe the role of aggregate in the concrete quantitatively and to increase the performance of high-flowing concrete effectively, parametric studies were carried out such as W/C, s/a, fineness modulus of aggregate, contribution degree of particle sizes, and the effect of 13mm aggregate and fine stone powder as a partial replacement of aggregates. And the effect of these factors on performance of the concrete was evaluated by measuring slump-flow and gap of penetration height in U-typed instrument. As a result, it was found that flowability of high-flowing concrete depends upon grading of fine aggregate more significantly than that of coarse aggregate and is enhanced greatly as fineness modulus of fine aggregate decreases and the value of s/a increases. In addition, the application of 13mm aggregate and fine stone powder are expected as a partial replacement of aggregate in order to increase the performance of high-flowing concrete more effectively.

A STUDY ON THE DISTORTION OF THE COPINGS FOR CERAMOMETAL CROWNS DURING REPEATED FIRING (도재전장금관을 위한 코핑의 변형에 관한 연구)

  • Lee, Ki-Hong;Chung, Hun-Young;Lee, Sun-Hyung;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.706-718
    • /
    • 1997
  • Ceramometal crowns are common restorations in fixed prosthodontics because of their casting accuracy, the high strength properties of the metal, and the cosmetic appearance of porcelain. However, deterioration of the initial fit of the metal coping has been observed after the porcelain firing cycle. The distortion due to repeated firing makes it difficult to fit crown margin and elicits microleakage. The major causes of distortion are the residual stress that accumulate during wax-up, casting, cold work and the induced stress caused by the mismatch of porcelain-metal thermal contraction. This study examined the marginal fit changes of metal copings in relation to repeated firing and the effects of heat treatment that reduce the distortion resulted from residual stress. The marginal changes of the copings that were treated with conventional method and those treated with heat before repeated firing, were evaluated. The metal die which represented preparations of a maxillary central incisor was fabricated, and 45 wax patterns were cast with nonprecious metal alloys. The heat treatment of each group was performed as follows. Group 1(control) : Casting - Devesting - Cold work - Firing Group 2 : Casting - Heat treatment - Devesting - Cold work - Firing Group 3 : Casting - Devesting - Cold work - Reinvesting - Heat treatment - Devesting - Firing The copings were fired 3 times. After each firing, the marginal fit changes were measured with inverted metallurgical microscope at the 4 reference points located at labial, lingual, and both proximal surface. Measurements were compared, and statistically analyzed. The results were as follows ; 1. In all groups, the highest value of marginal fit changes of the copings studied were found after the first firing cycle. 2. When the distortion of each experimental group at the first firing cycle were compared, group 1 exhibited the greatest changes($20-27{\mu}m$), followed by group 2($9-13{\mu}m$), and group 3($8-10{\mu}m$). 3. The copings treated with heat before devesting(group 2) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 4. The copings treated with heat after reinvesting(group 3) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 5. No siginificant differences in marginal fit changes were found between the copings treated with heat before devesting(group 2) and the copings treated with heat after reinvesting(group 3). (p>0.01)

  • PDF

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

Effect of Salinity-stratified Waters on Upward Migration and Ratio of Extracted DNA/RNA in Cochlodinium polykrikoides Margalef Based on the Ratio of Absorbance at 260 and 280nm (염분 구배가 Cochlodinium polykrikoides Margalef의 수직이동 및 DNA/RNA 비율에 미치는 영향)

  • Cho Eun Seob;Lee Young Sik
    • Journal of Life Science
    • /
    • v.15 no.3 s.70
    • /
    • pp.468-473
    • /
    • 2005
  • The coastal regions of Yeosu, the South Sea of Korea, has occurred annually the red tide which is caused by potentially ichthyotoxic dinoflagellate C. polykrikoides, with a wide avenue for exchange with oceanic waters and freshwater runoff from Sumjin river. We attempted to examine the variability in response to vertical migration and concentration of extracted DNA/RNA of C. polykrikoides exposed to salinity-stratified waters. The experimental aquarium of the 60 liter was employed to culture C. polykrikoides. One aquarium was supplied with only sea water, the other was consisted of sea water and freshwater. Experiment was conducted for 5 days. In experimental column (mixture of freshwater and sea water), salinity was maintained to 20 at upper and approximately 30 at bottom during the period of this study. The fluctuation with related to dissolved oxygen and pH was similar pattern to both columns. Chlorophyll a was significantly higher value at upper than bottom. During 24h, chlorphyll a on experimental column was extremely high on the top as soon as lighting, compared with control. With elapsed time, the gap between experimental and control columns was a little. In darkness, chlorophyll a was not significantly different between upper and bottom, most cells appeared to randomly distribute on column regardless of water layer. Fluctuation with related to concentration of extracted DNA and RNA based on ratio of absorbance of 260 and 280 nm in experimental column was higher at final day or diel migration than control. These results implied that a large volume of freshwater could be associated with influence of concentration of DNA and RNA, in particular, rapid upward movement caused massive fish kills as soon as sunset.

Prospects of Stable Production Technologies for Food Crops (식량 안정생산기술의 전망)

  • Chae Je Cheon;Gang Yang Sun;Lee Yeong Ho;Nam Jung Hyeon
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 1999.11a
    • /
    • pp.102-144
    • /
    • 1999
  • The major problems of food crop cultivation in Korea are low yield of most crops except rice. inefficient cultivation techniques for aged farmers. and low international competibility. Therefore, development of cultivation techniques of food crops should aim the yield. quality improvement, labor reduction and production cost. The primary issue for increasing the yield of soybean, barely and wheat is to reduce the yield gap between the farmer's yield and recommended ones of experiment station. More advanced cultivation techniques needs to be developed. and/or the conventional breeding methods to be reconsidered. The newly developed labor-saving mechanized technique needs to reduce labor hours , and the cost of agricultural implements and machineries. In other words the labor-saving mechanized technique should be developed based on the improvement of total farming system as well as systemic fundamental innovation of cultural methods. The efficiency of solar energy use in food production of Korea in 1997 is as low as $0.52{\%}$ so there is much room to increase yield. It is recommendable that the concept of food Production should be changed to energy Producing efficiency Per unit area basis from volume and weight of food materials. Moreover, introduction of resonable cropping system is needed to increase yield of main crops, farmer's income, solar energy use efficiency, and decrease of land service expenditure. Current cropping system emphasized on economic crops. especially in vegetables , is not desirable for resonable use of arable land. stability of agricultural management and staple food crop self-sufficiency ratio. It is desirable to increase food crops . that are energy of carbohydrate and protein rich and land dependent crops. in cropping system. And the agronomist should develop the cultural methods to replace food crops for food self-sufficiency and stable farming management instead of economic crops in current cropping system. Low-input and environmentally-sound crop cultivation techniques, especially nitrogen-reducing culture technique which is directly related to food crop quality, also needs to be developed urgently. The extended cultivation of corn in upland and barely and wheat in lowland as a feed stuffs is recommended to prevent further decrease of food self-sufficiency ratio, which is mainly caused by the high reliance on imported feed grain. It is also considered that the calculation and presentation methods of standard agricultural income needs to be improved. The current calculation method uses unit land area of 10a regardless of crop kinds , characteristics of agricultural management and cultivation scale. So, it is apt to lead misunderstanding of farm income value. Therefore. it should show an income of average farmers for certain number of years. Research and developing system for food producing is not desirable because they are conducted currently individual crop and mono-culture basis. But actual agricultural income is usually earned by cropping system including upland and lowland. For example. the barley and wheat is usually cultivated in double cropping system. The cooperation among research institutes such as university agribusiness. government and farmers is indispensible. The public information and education on importance and consumption habit of food crops is necessary in Korean society to increase food self-sufficiency through nationwide cooperation.

  • PDF

Performance Enhancement of Algorithms based on Error Distributions under Impulsive Noise (충격성 잡음하에서 오차 분포에 기반한 알고리듬의 성능향상)

  • Kim, Namyong;Lee, Gyoo-yeong
    • Journal of Internet Computing and Services
    • /
    • v.19 no.3
    • /
    • pp.49-56
    • /
    • 2018
  • Euclidean distance (ED) between error distribution and Dirac delta function has been used as an efficient performance criterion in impulsive noise environmentsdue to the outlier-cutting effect of Gaussian kernel for error signal. The gradient of ED for its minimization has two components; $A_k$ for kernel function of error pairs and the other $B_k$ for kernel function of errors. In this paper, it is analyzed that the first component is to govern gathering close together error samples, and the other one $B_k$ is to conduct error-sample concentration on zero. Based upon this analysis, it is proposed to normalize $A_k$ and $B_k$ with power of inputs which are modified by kernelled error pairs or errors for the purpose of reinforcing their roles of narrowing error-gap and drawing error samples to zero. Through comparison of fluctuation of steady state MSE and value of minimum MSE in the results of simulation of multipath equalization under impulsive noise, their roles and efficiency of the proposed normalization method are verified.

Experimental Study on Improvement of Pipe-rack Joint (Pipe-rack접합부 개선방법에 관한 실험적 연구)

  • Lee, Jong-Kun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2018
  • The development of new technology and process in industrial Plant which builds integrated structures, facilities and systems. Has become a key element for strengthening its competitiveness. Although domestic industrial Plant has demonstrated excellence in technology with a persistent increase in order quantity and orders received, the technology gap between countries has narrowed due to global construction trend. Therefore, it is necessary to develop new technology that could help overcome constraints and limitations of the current one to follow the trend in the age of unlimited competition. This study has focused on assembly technology of Pipe-rack joint connection in an effort to strengthen technological competitiveness in industrial Plant. Through an analysis of earlier studies on Pipe-rack and a coMParative analysis of strengths and weaknesses of current assembly technology of it, a new design plan has been made to improve it efficiently. In doing this, standards for design factors of both structural and performance features have been drawn, and value of stress, strain, moment and rotation has been calculated using finite element analysis. As a result, installation technology of modular type Pipe-rack, which has not been developed in Korea and is differentiated from the current one, has been developed. It is considered that the technology reduces work time and saves cost due to simplified joint connection of steel structure, unlike the current one. Moreover, since it is installed without a welding process in the field, industrial accidents would be reduced, which is likely to have economic competitiveness and satisfy.

A STUDY ON THE PHYSICAL PROPERTIES OF RESTORATIVE MATERIALS FOR PHOTO-POLYMERIZATION OF ARGON LASER (아르곤 레이저를 이용한 광중합 수복재의 물리적 성질에 관한 연구)

  • Ju, Sang-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.368-382
    • /
    • 1998
  • The purpose of this study is to evaluate and compare the results of argon laser for 5 seconds, argon laser for 10 seconds, and visible light for 40 seconds photo-polymerization in compressive strength, microhardness, curing depth, temperature rising during polymerization, and polymerization shrinkage. Hybrid type composite resin(Z-100) and compomer(Dyract) were used to be compared. The compressive strength was measured by an Instron(1mm/min cross head speed) in 60 specimens and the microhardness of the surface was expressed by Vickers Hardness Number(VHN) in 30 specimens. The curing depth was evaluated comparing the different values of upper and lower VHN according to irradiation time and thickness for the light source polymerization in 60 specimens. The temperature rising during photopolymerization was observed by the temperature change with thermocouple sensitizer beneath 40 specimens at the argon laser for 10 seconds and visible light 40 seconds irradiation. The polymerization shinkage was evaluated by calculating the decrease of % volume by using a dilatometer in 30 specimens. The results were as follows ; 1. In the case of compressive strength, the argon laser polymerization groups were higher than visible light group in Z-100 (p<0.05). In Dyract, the argon laser 5 seconds group did not show a significant difference with the visible light 40 seconds group. The argon laser 10 seconds group showed the markedly low value when compared with other groups (p<0.05) 2. In microhardness, Z-100 was better than Dyract when comparing by VHNs (p<0.05); however, there was not a significant difference between two materials in the visible light 40 seconds group and the argon laser 10 seconds group. 3. In the study of curing depth, Z-100 showed the consistent polymerization in argon laser irradiation because there was no difference in the VHN decrease according to the thickness change. Over the thickness control, the results did not show a significant difference between visible light and argon laser group in Z-100; however, in the case of Dyract, the visible light 40 seconds group was better than the argon laser groups(p<0.05). 4. There was a significant difference between the two materials in temperature rising during polymerization (p<0.05), but not a significant difference between irradiation times, 5. There was not a significant difference between the two materials in polymerization shrink age. The argon laser 5 seconds group was smaller than the other groups (p<0.05). It could be concluded that Z-100 polymerization was recommended to use the argon laser for reduction of the irradiation time while Dyract was recommended to use the visible light polymerization.

  • PDF