Reliability and Validity of an Electronic Inspiratory Loading Device for Assessing Pulmonary Function in Patients with COPD

  • Lee, Seugcheol;You, Seongkwang;Yang, Subin;Park, Daesung
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권1호
    • /
    • pp.40-47
    • /
    • 2021
  • Objective: The purpose of this study is to prove the reliability and validity of the Power breath K5 and to compare it with pony FX. Power breathe K5 is one type of device can assess automatically Maximum inspiratory pressure (MIP), Peak inspiratory pressure, Peak inspiratory flow (PIF). Design: Cross-sectional study. Methods: Thirty-five COPD patients participated in the test to investigate for the intra relater reliability and concurrent validity. The tests MIP, Vital capacity (VC), PIF were measured by Powerbreathe K5 and Pony Fx. Data was analyzed by intraclass correlation reliability (ICC) value and a standard error of measurement and Bland-Altman plots for reliability and pearson correlation for validity. Results: Intra rater reliability of the Powerbreathe K5 was very high at MIP (ICC=0.977 95%CI 0.956~0.989, SEM=8.665, MDC=0.295), PIF (ICC=0.966 95%CI 0.933~0.93, SEM=8.665, MDC=0.295), VC (ICC=0.949 95CI 0.902~0.974, SEM=0.042, MDC=0.116). The Powerbreath K5 was significant correlation compared with Pony Fx in assessment for MIP (r=0.971, p<0.05) and vital capacity (r=0.534, p<0.05). Conclusion: In this study, We investigated the clinical usefulness of the Powerbreath K5 in evaulating the MIP, VC and PIF with COPD patients with high reliability and validity.

한국판 간호그룹파워 도구의 타당도와 신뢰도 검증 (Validity and Reliability of K-SKAGOAO for Korean Nursing Groups)

  • 성영희;이미경;정정희;박현태;김선우
    • 임상간호연구
    • /
    • 제20권3호
    • /
    • pp.372-383
    • /
    • 2014
  • Purpose: The purpose was to determine the content validity of a semantic revision of items on a reliable and valid instrument, the Sieloff-King Assessment of Group Outcome Attainment (Power) within Organizations in Korea (K-SKAGOAO). Methods: The target population for research was chief nurse officers (CNOs) of all hospital within Korea. A sample of 303 hospitals from across the Korea was selected through a stratified random sampling process. A total of 174 CNOs comprised the final sample. Psychometric evaluation of the K-SKAGOAO included: (a) criterion-related validity (b) factor analysis and (c) internal consistency reliability using Cronbach's alpha coefficients. Results: The Convergent validity and criterion-related validity were supported. Cronbach's alpha coefficient for the K-SKAGOAO was .95. Subscale alphas ranged from .60 to .86. Conclusion: The K-SKAGOAO and related subscales show validity and internal reliability. A nursing group of any size can use the K-SKAGOAO to both assess the group's level of outcome attainment and develop strategies to further improve that level.

모유수유 적응 측정 도구 개발 (Development of a Breast Feeding Adaptation Scale (BFAS))

  • 김선희
    • 대한간호학회지
    • /
    • 제39권2호
    • /
    • pp.259-269
    • /
    • 2009
  • Purpose: The aim of this study was to develop a breast feeding adaptation scale (BFAS) to evaluate adaptation to breastfeeding for breastfeeding mothers and their infants and to test the validity and reliability of the instrument. Methods: The study was conducted as follows: application of the conceptual framework, identification of the content domains, items generation, and test of validity and reliability. In order to test validity and reliability, two panels of experts reviewed items and subcategories of the preliminary questionnaire and then data were collected from 329 mothers who were up to 4 weeks postpartum and breastfeeding. Descriptive statistics, t-test, factor analysis, and Cronbach's alpha were used to analyze the data. Results: The conceptual framework was based on the Roy adaptation model. The content domains were developed via literature review, review of instruments, and data acquired from the interviews of breastfeeding mothers and nurses. A total of 69 items belonging to 8 domains were generated. A reduction to 44 preliminary items was accomplished through content validity analysis. Factor analysis extracted 8 factors with a total of 27 items on a 5-point Likert scale. Content validity, construct validity, criterion validity, and reliability of the BFAS were established. Conclusion: The newly developed BFAS is a reliable and valid instrument with which the adaptation of breastfeeding mothers and their infants to the breastfeeding behavior can be evaluated.

간호대학생을 대상으로 한 한국어 버전 학생 프리젠티즘 측정도구(K-PSS)의 신뢰도와 타당도 분석 (Reliability and Validity of the Korean Version of Presenteeism Scale for Students (K-PSS) in Nursing Students)

  • 김진희;전재희
    • 근관절건강학회지
    • /
    • 제26권3호
    • /
    • pp.281-289
    • /
    • 2019
  • Purpose: This study aims to develop the Korean version of Presenteeism Scale for Students and verify its reliability and validity. Methods: This study conducted a survey with 320 undergraduate students who are attending nursing departments at three universities. The survey was conducted twice, from June 1 to August 31, 2017. Results: The Cronbach's α of K-PSS was .70 indicating high reliability. As a result of testing the content validity of K-PSS was verified by calculating the Item level-Content Validity Index (I-CVI) of .87. The correlation between Medical Outcome Study 36-item Short Form Health Survey (SF-36) score and Work Impairment Score (WIS), Work Output Score (WOS), Hours of absenteeism (HA) was analyzed to verify the concurrent validity of K-PSS. SF-36 score was correlated with WIS, WOS, HA. To test the differentiated validity of K-PSS, a total of 38 subjects were assessed by the paired t-test. As a result, only WIS score showed a significant difference between pre-test and post-test. Conclusion: Since the reliability and validity of the K-PSS developed through this study have been verified, it is expected to be used in various studies related to the presenteeism of students.

심혈관질환용 회복력(Cardiovascular Disease Resilience) 측정도구 개발 및 평가 (Development of a Cardiovascular Disease Resilience Scale)

  • 신수진
    • 성인간호학회지
    • /
    • 제22권2호
    • /
    • pp.161-170
    • /
    • 2010
  • Purpose: The purpose of this study was to develop a Cardiovascular Disease Resilience (CDR) scale to evaluate disease specific resilience for recovery. Methods: The study was conducted as follows: items generation, and test of validity and reliability. Items were developed via literature review, review of instruments, and data acquired from the interviews. In order to test validity and reliability, seven panels of experts reviewed the preliminary questionnaire and then data were collected from 550 cardiovascular disease patients. Factor analysis, Pearson correlation, ANOVA, and Cronbach's alpha were used to analyze the data. Results: In the preliminary stage, forty-four items were generated. A reduction to 40 items was accomplished through content validity analysis. Factor analysis extracted 7 factors with a total of 25 items. The CDR items were moderately correlated with the subscales of the CD-RISC (Connor-Davidson Resilience Scale) and the mean score of CDR was associated with quality of life measured with CD-QOL (Cardiovascular Disease Quality of Life). Cronbach's ${\alpha}$=.84. Conclusion: Content validity, construct validity, criterion validity, and reliability of the CDR were established. The CDR is a reliable and valid instrument which the resilience of cardiovascular disease specific recovery state can be evaluated.

QOL의 관점에 입각한 장애인고용촉진제도·정책 평가 척도의 신뢰성·타당성 검증 (The Verification of the Reliability and Validity of Employment Promotion Tool for Persons with Disabilities in the Aspect of the Quality of Life(QOL-EPAT))

  • 권해진
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2016년도 춘계 종합학술대회 논문집
    • /
    • pp.387-388
    • /
    • 2016
  • Kwon (2015) was developed Employment Promotion Tool for Persons with Disabilities in the Aspect of the Quality of Life(QOL-EPAT). But its reliability and validity have not been verified yet. Therefore, this study aimed to verify the reliability, content validity and construct validity of QOL-EPAT. This study was conducted with a disability employment specialists. Period May to October 2015, six months, was distributed to collect the questionnaire. Reliability of QOL-EPAT was estimated using the internal consistency method; both the coefficient of Cronbach's ${\alpha}$ were over 0.7. Construct Validity; Construct validity was verified using structural equation modeling (SEM). Goodness of fit index (GFI), Adjusted goodness of fit index (AGFI), comparative fit index (CFI), tucker-Lewis index (TLI) and root mean square error of approximation (RMSEA) are the suitability indices of SEM. As the result, GFI=0.898; AGFI=0.844; CFI=0.961; TLI=0.949 and RMSEA=0.069. The validity was verified because the values of GFI, AGFI, CFI, TLI and RMSEA were within the goodness-of-fit range. Thus, impaired employs promoters of Japan also provided which allows for analysis of the policy by using a validated scale.

  • PDF

전문직 간 핵심역량 중요성 인식 측정도구의 신뢰도와 타당도 검증 (Reliability and Validity of Perception on Importance of Interprofessional Core Competencies(PI-ICCP) Scale)

  • 홍민주;전민경
    • 보건의료산업학회지
    • /
    • 제13권4호
    • /
    • pp.253-263
    • /
    • 2019
  • Objectives: This study evaluated the perception on importance of interprofessional core competencies (PI-ICCP) scale. Methods: Data were collected from 353 college students of health. Content validity was tested using the content validity index for individual items(I-CVI) and for scale(S-CVI). Criterion validity was tested using the professional competencies scale developed by Choi. Reliability was evaluated using Cronbach's coefficient alpha. The goodness-of-fit of the construct validity was determined through exploratory and confirmatory factor analyses. Results: The I-CVI of each item was .8 or higher for all items, and the S-CVI was .98. The reliability of the PI-IPCC was Cronbach's α=.98. The goodness-of-fit indices of the model were χ2=1811.54(p<.001), the comparative fit index (CFI)=.91, and root mean square error of approximation (RMSEA)=.08, which satisfied the criteria. Conclusions: The construct and criterion-related validity of the perception for PI-ICCP scale were a good fit, so the instrument is appropriate for measuring perception on importance of interprofessional core competencies. Further research will be required using this instrument to investigate perception of interprofessional core competencies of health professionals.

Development of a lesbian, gay, bisexual, and transgender cultural competence scale for nurses in South Korea: a methodological study

  • Min Kyung Kim;Hye Young Kim
    • 여성건강간호학회지
    • /
    • 제30권2호
    • /
    • pp.107-116
    • /
    • 2024
  • Purpose: This study was conducted to develop a cultural competence scale for nurses regarding the lesbian, gay, bisexual, and transgender (LGBT) community and to test its validity and reliability. Methods: The study adhered to the 8-step process outlined by DeVellis, with an initial set of 25 items derived through a literature review and individual interviews. Following an expert validity assessment, 24 items were validated. Subsequently, a preliminary survey was conducted among 23 nurses with experience caring for LGBT patients. Data were then collected from a final sample of 322 nurses using the 24 items. Item analysis, item-total score correlation, examination of construct and convergent validity, and reliability testing were performed. Results: The item-level content validity index exceeded .80, and the explanatory power of the construct validity was 63.63%. The factor loadings varied between 0.57 and 0.80. The scale comprised five factors: cultural skills, with seven items; cultural awareness, with five items; cultural encounters, with three items; cultural pursuit, with three items; and cultural knowledge, with three items; totaling 21 items. Convergent validity demonstrated a high correlation, affirming the scale's validity. Internal consistency analysis yielded an overall reliability coefficient of 0.97, signifying very high reliability. Each item is scored from 1 to 6 (total score range, 21-126), with higher scores reflecting greater cultural competence in LGBT care. Conclusion: This scale facilitates the measurement of LGBT cultural competence among nurses. Therefore, its use should provide foundational data to support LGBT-focused nursing education programs.

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

Reliability and validity of rasterstereography measurement for spinal alignment in healthy subjects

  • Yi, Yoon-Sil;Yoo, Seul-Ki;Lee, Da-Gam;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권1호
    • /
    • pp.22-28
    • /
    • 2016
  • Objective: The Back Mapper is one type of Rasterstereography and it can be used in the clinic without radiation exposure. The purpose of our study was to prove the reliability and validity of the Back Mapper and to compare it with the Spinal Mouse, which is an assessment tool for spinal curvatures using a wheeled mouse, and the Cobb angle by X-ray. Design: Cross-sectional study. Methods: Twenty healthy adults participated in the test to investigate for the inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with assessment devices for scoliosis such as the Back Mapper, Spinal Mouse and Cobb's angle. Data was analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement for reliability and correlation analysis for validity. Results: Intra-rater reliability of the Back Mapper was good (Cronbach's ${\alpha}$=0.821-0.984, ICC=0.696-0.969) except for assessing the lordotic angle. Inter-rater reliability was good (Cronbach's ${\alpha}$=0.870-0.958, ICC=0.770-0.919) in assessment for trunk imbalance, rotation of scapulae, thoracic angle, lumbar angle, and kyphotic angle. The kyphotic angle in the Spinal Mouse had a significant correlation icompared with the Back Mapper (r=0.510, p<0.05), and the Cobb's angle from an X-ray had a significant correlation with trunk inclination (r=0.532, p<0.05). Conclusions: These findings provide good intra-reliability of the Back Mapper in healthy subjects, but the Back Mapper requires more experienced practice to have good inter-reliability. Also, the variables of the Back Mapper does not seem as appropriate compared with the Cobb angle by X-ray.