• Title/Summary/Keyword: validation.

Search Result 8,323, Processing Time 0.031 seconds

Development and Validation of an Official Analytical Method for Determination of Ipfencarbazone in Agricultural Products using GC-ECD (GC-ECD를 이용한 농산물 중 Ipfencarbazone의 신규분석법 개발 및 검증)

  • Jang, Jin;Kim, Heejung;Lee, Eun-Hyang;Ko, Ah-Young;Ju, Yunji;Kim, Sooyeon;Chang, Moon-Ik;Rhee, Gyu-Seek
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.210-217
    • /
    • 2015
  • Ipfencarbazone is a herbicide of the tetrazolinone class, and is believed to be an inhibitor of very long chain fatty acids (VLCFAs), which control cell division in weeds. The objective of this study was to develop and validate an official analytical method for ipfencarbazone determination in agricultural products. The ipfencarbazone residues in agricultural products were extracted with acetone, partitioned with n-hexane, and then purified through silica SPE cartridge. Finally, the analyte was quantified by gas chromatograph-electron capture detector (GC-ECD) and confirmed with gas chromatograph/mass spectrometer(GC/MS). The linear range of ipfencarbazone was 0.01 to 1.0 mg/L with the coefficient of determination ($r^2$) of 0.9999. The limit of detection (LOD) and quantification (LOQ) was 0.003 and 0.01 mg/kg, respectively. In addition, average recoveries of ipfencarbazone ranged from 80.6% to 112.3% at the different concentration levels LOQ, 10LOQ and 50LOQ, while the relative standard deviation was 2.2-8.6%. All values were consistent with the criteria ranges requested in the CODEX guidelines. Furthermore, and inter-laboratory study was conducted to validate the method. This proposed method for determination of ipfencarbazone residues in agricultural products can be used as an official analytical method.

An Operations Study on a Home Health Nursing Demonstration Program for the Patients Discharged with Chronic Residual Health Care Problems (추후관리가 필요한 만성질환 퇴원환자 가정간호 시범사업 운영 연구)

  • 홍여신;이은옥;이소우;김매자;홍경자;서문자;이영자;박정호;송미순
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.2
    • /
    • pp.227-248
    • /
    • 1990
  • The study was conceived in relation to a concern over the growing gap between the needs of chronic patients and the availability of care from the current health care system in Korea. Patients with agonizing chronic pain, discomfort, despair and disability are left with helplessly unprepared families with little help from the acute care oriented health care system after discharge from hospital. There is a great need for the development of an alternative means of quality care that is economically feasible and culturally adaptible to our society. Thus, the study was designed to demonstrate the effectiveness of home heath care as an alternative to bridge the existing gap between the patients' needs and the current practice of health care. The study specifically purports to test the effects of home care on health expenditure, readmission, job retention, compliance to health care regime, general conditions, complications, and self-care knowledge and practices. The study was guided by the operations research method advocated by the Primary Health Care Operations Research Institute(PRICOR) which constitutes 3 stages of research : namely, problem analysis solution development, and solution validation. The first step in the operations research was field preparation to develop the necessary consensus and cooperation. This was done through the formation of a consulting body at the hospital and a steering committee among the researchers. For the stage of problem analysis, the Annual Report of Seoul National University Hospital and the patients records for last 5 years were reviewed and selective patient interviews were conducted to find out the magnitude of chronic health problems and areas of unmect health care needs to finally decide on the kinds of health problems to study. On the basis of problem analysis, the solution development stage was devoted to home care program development asa solution alternative. Assessment tools, teaching guidelines and care protocols were developed and tested for their validity. The final stage was the stage of experimentation and evaluation. Patients with liver diseases, hemiplegic and diabetic conditions were selected as study samples. Discharge evaluation, follow up home care, measurement and evaluation were carried out according to the protocols of care and measurement plan for each patient for the period of 6 months after discharge. The study was carried out for the period from Jan. 1987 to Dec. 1989. The following are the results of the study presented according to the hypotheses set forth for the study ; 1. Total expenditures for the period of study were not reduced for the experimental group, however, since the cost per hospital visit is about 4 times as great as the cost per home visit, the effect of cost saving by home care will become a reality as home care replaces part of the hospital visits. 2. The effect on the rate of readmission and job retention was found to be statistically nonsignificant though the number of readmission was less among the experimental group receiving home care. 3. The effect on compliance to the health care regime was found to be statistically significant at the 5% level for hepatopathic and diabetic patients. 4. Education on diet, rest and excise, and medication through home care had an effect on improved liver function test scores, prevention of complications and self - care knowledge in hepatopathic patients at a statistically significant level. 5. In hemiplegic patient, home care had an effect on increased grasping power at a significant level. However. there was no significant difference between the experimental and control groups in the level of compliane, prevention of complications or in self-care practices. 6. In diabetic patients, there was no difference between the experimental and control groups in scores of laboratory tests, appearance of complications, and self-care knowledge or self -care practices. The above findings indicate that a home care program instituted for such short term as 6 months period could not totally demonstrate its effectiveness at a statistically significant level by quantitative analysis however, what was shown in part in this analysis, and in the continuous consultation sought by those who had been in the experimental group, is that home health care has a great potential in retarding or preventing pathological progress, facilitating rehabilitative and productive life, and improving quality of life by adding comfort, confidence and strength to patients and their families. For the further studies of this kind with chronic patients it is recommended that a sample of newly diagnosed patients be followed up for a longer period of time with more frequent observations to demonstrate a more dear- cut picture of the effectiveness of home care.

  • PDF

Role of enzyme immunoassay for the Detection of Helicobacter pylori Stool Antigen in Confirming Eradication After Quadruple Therapy in Children (소아에서 4제요법 후 enzyme immunoassay에 의한 Helicobacter pylori 대변 항원 검출법의 유용성에 대한 연구)

  • Yang, Hye Ran;Seo, Jeong Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.153-162
    • /
    • 2004
  • Purpose: The Helicobacter pylori stool antigen (HpSA) enzyme immunoassay is a non-invasive test for the diagnosis and monitoring of H. pylori infection. But, there are few validation studies on the HpSA test after eradication in children. The aim of this study was to assess the diagnostic accuracy of HpSA enzyme immunoassay for the detection of H. pylori to confirm eradication in children. Methods: From January 2001 to October 2003, 164 tests were performed in 146 children aged 1 to 17.5 years (mean $9.3{\pm}4.3$ years). H. pylori infection was confirmed by endoscopy-based tests (rapid urease test, histology, and culture). All H. pylori infected children were treated with quadruple regimens (Omeprazole, amoxicillin, metronidazole and bismuth subcitrate for 7 days). Stool specimens were collected from all patients for the HpSA enzyme immunoassay (Primier platinum HpSA). The results of HpSA tests were interpreted as positive for $OD{\geq}0.160$, unresolved for $$0.140{\leq_-}OD$$<0.160, and negative for OD<0.140 at 450 nm on spectrophotometer. Results: 1) One hundred thirty-one HpSA tests were performed before treatment. The result of HpSA enzyme immunoassay showed three false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value of HpSA enzyme immunoassay before treatment were 96.4%, 97.1%, 90%, and 99%, respectively. 2) Thirty-three HpSA enzyme immunoassay were performed at least 4 weeks after eradication therapy. The results of HpSA enzyme immunoassay showed two false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value after treatment were 88.9%, 91.7%, 80%, and 95.7%, respectively. Conclusion: Diagnostic accuracy of the HpSA enzyme immunoassay after eradication therapy was as high as that of the HpSA test before eradication therapy. The HpSA enzyme immunoassay was found to be a useful non-invasive method to confirm H. pylori eradication in children.

  • PDF

A Comparative Study on the Effective Deep Learning for Fingerprint Recognition with Scar and Wrinkle (상처와 주름이 있는 지문 판별에 효율적인 심층 학습 비교연구)

  • Kim, JunSeob;Rim, BeanBonyka;Sung, Nak-Jun;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.21 no.4
    • /
    • pp.17-23
    • /
    • 2020
  • Biometric information indicating measurement items related to human characteristics has attracted great attention as security technology with high reliability since there is no fear of theft or loss. Among these biometric information, fingerprints are mainly used in fields such as identity verification and identification. If there is a problem such as a wound, wrinkle, or moisture that is difficult to authenticate to the fingerprint image when identifying the identity, the fingerprint expert can identify the problem with the fingerprint directly through the preprocessing step, and apply the image processing algorithm appropriate to the problem. Solve the problem. In this case, by implementing artificial intelligence software that distinguishes fingerprint images with cuts and wrinkles on the fingerprint, it is easy to check whether there are cuts or wrinkles, and by selecting an appropriate algorithm, the fingerprint image can be easily improved. In this study, we developed a total of 17,080 fingerprint databases by acquiring all finger prints of 1,010 students from the Royal University of Cambodia, 600 Sokoto open data sets, and 98 Korean students. In order to determine if there are any injuries or wrinkles in the built database, criteria were established, and the data were validated by experts. The training and test datasets consisted of Cambodian data and Sokoto data, and the ratio was set to 8: 2. The data of 98 Korean students were set up as a validation data set. Using the constructed data set, five CNN-based architectures such as Classic CNN, AlexNet, VGG-16, Resnet50, and Yolo v3 were implemented. A study was conducted to find the model that performed best on the readings. Among the five architectures, ResNet50 showed the best performance with 81.51%.

Simultaneous Determination and Monitoring of Bisphenols in River Water using Gas Chromatography-Mass Spectrometry (GC-MS 를 이용한 하천수 중 Bisphenol계 화합물의 동시분석 및 모니터링)

  • Kim, Jihyun;Choi, Jeong-Heui;Kang, Tae-Woo;Kang, Taegu;Hwang, Soon-Hong;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.154-160
    • /
    • 2017
  • BACKGROUND:This study was carried out to establish an efficient sample preparation for the simultaneous determination of bisphenols (BPs) in river water samples using gas chromatography-mass spectrometry (GC-MS). Sample preparation was examined with conventional extraction methods, such as solid-phase extraction (SPE) and liquid-liquid extraction (LLE), and their efficiency was compared with validation results, including linearity of calibration curve, method detection limit (MDL), limit of quantification (LOQ), accuracy, and precision. METHODS AND RESULTS:The BPs (bisphenol A, BPA; bisphenol B, BPB; bisphenol C, BPC; bisphenol E, BPE; bisphenol F, BPF; bisphenol S, BPS) were analyzed using GC-MS. The range of MDLs by SPE and LLE methods was $0.0005{\sim}0.0234{\mu}g/L$ and $0.0037{\sim}0.2034{\mu}g/L$, and that of LOQs was $0.0015{\sim}0.0744{\mu}g/L$ and $0.0117{\sim}0.6477{\mu}g/L$, respectively. The calibration curve obtained from standard solution of $0.004{\sim}4.0{\mu}g/L$ (SPE) and $0.016{\sim}16{\mu}g/L$ (LLE) showed good linearity with $r^2$ value of 0.9969 over. Accuracy was 93.2~108% and 97.4~120%, and precision was 1.7~4.6% and 0.7~6.5%, respectively. The values of MDL and LOQ resulted from the SPE method were higher than those from the LLE method, particularly those values of BPA were highest among the BPs. Based on the results, the SPE method was applied to determine the BPs in river water samples. Water samples were collected from mainstream, tributary and sewage wastewater treatment plants (SWTPs) in the Yeongsan river basin. The concentration of BPB, BPC, BPE, BPF and BPS were not detected in all sites, whereas BPA was ranged $0.0095{\sim}0.2583{\mu}g/L$, which was $0.0166{\sim}0.0810{\mu}g/L$ for mainstreams, $0.0095{\sim}0.2583{\mu}g/L$ for tributaries, $0.0352{\sim}0.1217{\mu}g/L$ for SWTPs. CONCLUSION: From these results, the SPE method was very effective for the simultaneous determination of BPs in river water samples using GC-MS. We provided that it is a convenient, reliable and sensitive method enough to monitor and understand the fate of the BPs in aquatic ecosystems.

The Cutoff Value of HbA1c in Predicting Diabetes and Impaired Fasting Glucose (당뇨병 및 공복혈당장애 예측을 위한 당화혈색소 값)

  • Kwon, Seyoung;Na, Youngak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.2
    • /
    • pp.114-120
    • /
    • 2017
  • There have been many studies to develop methods for predicting diabetes and to prevent diabetes. The validity of glycated hemoglobin (HbA1c), one of the commonly known tools in predicting diabetes, has been verified by many previous studies. In this study, we examined the cutoff value of HbA1c for diabetes and impaired fasting glucose (IFG). Based on this study, we proposed a proper clinical guideline and evaluated the validation of the guideline. Excluding those without blood glucose and HbA1c data, we used the data of 5,161 subjects (2,281 men and 2,880 women) over the age of 20 years from the 2015 Korean National Health and Nutrition Examination Survey. The correlation efficient of fasting plasma glucose (FPG) and HbA1c was 0.79, indicating a strong relationship. Howeve, the correlation efficient of FPG and HbA1c was low, showing 0.27 in non-diabetes, 0.39 in IFG, and 0.66 in diabetes, showing a strong relationship. The cutoff value of HbA1c for predicting diabetes using ROC curve was 6.05% (sensitivity 84.6%, and specificity 92.0%), and AUC was 0.941 (0.937 in men, and 0.946 in women). The cutoff value of HbA1c for predicting IFG using ROC curve was 5.55% (sensitivity 64.5%, and specificity 70.0%), and AUC was 0.733 (0.708 in men, and 0.764 in women). Therefore, it may not be appropriate to apply the guidelines for diagnosing IFG since sensitivity and specificity were below 70%. For future studies retarding the cutoff value of HbA1c in predicting IFG, high sensitivity and specificity are expected if we segment the reference range of IFG.

Improving the Usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: V. Field Validation of the Sky-condition based Lapse Rate Estimation Scheme (기상청 동네예보의 영농활용도 증진을 위한 방안: V. 하늘상태 기반 기온감률 추정기법의 실용성 평가)

  • Kim, Soo-ock;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.3
    • /
    • pp.135-142
    • /
    • 2016
  • The aim of this study was to confirm the improvement of efficiency for temperature estimation at 0600 and 1500 LST by using a simple method for estimating temperature lapse rate modulated by the amount of clouds in comparison with the case adopting the existing single temperature lapse rate ($-6.5^{\circ}C/km$ or $-9^{\circ}C/km$). A catchment of the 'Hadong Watermark2,' which includes Hadong, Gurye, and Gwangyang was selected as the area for evaluating the practicality of the temperature lapse rate estimation method. The weather data of 0600 and 1500 LST at 12 weather observation sites within the catchment were collected during the entire year of 2015. Also, the 'sky condition' of digital forecast products of KMA in 2015 ($5{\times}5km$ lattice resolution) were overlapped with the catchment of the 'Hadong Watermark2,' to calculate the spatial average value within the catchment, which were used to simulate the 0600 and 1500 LST temperature lapse rate of the catchment. The estimation errors of the temperatures at 0600 LST were ME $-0.39^{\circ}C$ and RMSE $1.45^{\circ}C$ in 2015, when applying the existing temperature lapse rate. Using the estimated temperature lapse rate, they were improved to ME $-0.19^{\circ}C$ and RMSE $1.32^{\circ}C$. At 1500 LST, the effect of the improvements found from the comparison between the existing temperature lapse rate and the estimated temperature lapse rate were minute, because the estimated lapse rate of clear days is not very different from the existing lapse rate. However, the estimation errors of the temperatures at 1500 LST during cloudy days were improved from ME $-0.69^{\circ}C$, RMSE $1.54^{\circ}C$ to ME $-0.51^{\circ}C$, RMSE $1.19^{\circ}C$.

Characteristics of Sleep Patterns in Korean Women Golfers (여자 골프선수들의 수면양상조사)

  • Park, Soo Yeon;Shin, Won-Chul
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.2
    • /
    • pp.80-84
    • /
    • 2014
  • Introduction: Sleep has numerous important physiological and cognitive functions that may be particularly important to elite athletes. Sleep deprivation can have significant effects on athletic performance. However, there are few published data related to the amount of sleep obtained by elite athletes. We investigated sleep patterns of Korean women golfers using sleep-related questionnaires. Methods: For this study, 98 Korean university women golfers and 46 age- and sex-matched controls were recruited. All subjects were asked to complete the self-administered sleep questionnaire consisting of questions about habitual sleep patterns (sleep onset time, sleep latency, awakening time in the morning, day time napping time), exercise habits, Epworth Sleepiness Scale (ESS), Insomnia Severity Index (ISS), Pittsburgh Sleep Quality Index (PSQI), validation of the Perceived Stress Scale (PSS), and Beck Anxiety Inventory (BAI). Results: The sleep onset time was significantly earlier (pm 23 : $05{\pm}00$ : 52 and 00 : $14{\pm}00$ : 51 ; t = 5.287, p < 0.001), the waking time was later (am 07 : $21{\pm}01$ : 09 and 6 : $35{\pm}00$ : 32; t = -2.715, p = 0.008), the weekday total sleep time was greater ($417.77{\pm}78.18$ minute and $351.52{\pm}77.83$ minute ; t = 4.406, p = 0.001), and the daytime nap time was greater ($77.73{\pm}41.28$ minute and $20.22{\pm}33.03$ minute ; t = 7.623, p < 0.001) in the golf athletes compared to the controls. The PSQI scores were significantly lower, but estimated sleep latency and ESS, ISS, PSS, and BAI scores were not different among the two groups. Conclusion: This study suggests that Korean university women golfers have good sleep patterns resulting in no difference in sleep-related stress compared to age- and sex-matched control students.

Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry (시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석)

  • Heo, Bo-Reum;Kwon, NamHee;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • The epidemic of disorders associated with synthetic stimulants, such as methamphetamine (MA) and amphetamine (AP), is a health, social, legal, and financial problem. Owing to the high potential of their abuse and addiction, reliable analytical methods are required to detect and identify MA, AP, and their metabolites in biological samples. Thus, a dilute-and-shoot liquid chromatography-tandem mass spectrophotometry (LC-MS/MS) was developed for simultaneous determination of MA, 4-hydroxymethamphetamine (4HMA), AP, and 4-hydroxyamphetamine (4HA) in urine. Urine sample ($100{\mu}L$) was mixed with $50{\mu}L$ of mobile phase consisting of 0.4 % formic acid and methanol and $50{\mu}L$ of working internal-standard solution. Aliquots of $8{\mu}L$ diluted urine was injected into the LC-MS/MS system. For all analytes, chromatographic separation was performed using a C18 reversed-phase column with gradient elution and a total run time of 5 min. The identification and quantification were performed by multiple reaction monitoring (MRM). Linear least-squares regression was conducted to generate a calibration curve, with $1/x^2$ as the weighting factor. The linear ranges were 2.0-200, 1.0-800, and 10-2500 ng/mL for 4HA and 4HMA, AP, and MA, respectively. The inter- and intraday precisions were within 6.6 %, whereas the inter- and intraday accuracies ranged from -14.9 to 11.3 %. The low limits of quantification were 2.0 ng/mL (4HA and 4HMA), 1.0 ng/mL (AP), and 10 ng/mL (MA). The proposed method exhibited satisfactory selectivity, dilution integrity, matrix effect, and stability, which are required for validation. Moreover, the purification efficiency of high-speed centrifugation was clearly higher than 6-15 % for QC samples (n=5), which was higher than that of the membrane-filtration method. The applicability of the proposed method was tested by forensic analysis of urine samples from drug abusers.

Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition (전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Jongmin
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.15-27
    • /
    • 2020
  • Streamflow discharge as a fundamental riverine quantity plays a crucial role in water resources management, thereby requiring accurate in-situ measurement. Recent advances in instrumentations for the streamflow discharge measurement has complemented or substituted classical devices and methods. Among various potential methods, surface current meter using microwave has increasingly begun to be applied not only for flood but also normal flow discharge measurement, remotely and safely enabling practitioners to measure flow velocity postulating indirect contact. With minimized field preparedness, this method facilitated and eased flood discharge measurement in the difficult in-situ conditions such as extreme flood in active ways emitting 24.125 GHz microwave without relying on natural lights. In South Korea, a rectangular shaped instrument named with Microwave Water Surface Current Meter (MWSCM) has been developed and commercially released around 2010, in which domestic agencies charging on streamflow observation shed lights on this approach regarding it as a potential substitute. Considering this brand-new device highlighted for efficient flow measurement, however, there has been few noticeable efforts in systematic and comprehensive evaluation of its performance in various measurement and riverine conditions that lead to lack in imminent and widely spreading usages in practices. This study attempted to evaluate the MWSCM in terms of instrumen's monitoring configuration particularly regarding tilt and yaw angle. In the middle of pointing the measurement spot in a given cross-section, the observation campaign inevitably poses accuracy issues related with different tilt and yaw angles of the instrument, which can be a conventionally major source of errors for this type of instrument. Focusing on the perspective of instrument configuration, the instrument was tested in a controlled outdoor river channel located in KICT River Experiment Center with a fixed flow condition of around 1 m/s flow speed with steady flow supply, 6 m of channel width, and less than 1 m of shallow flow depth, where the detailed velocity measurements with SonTek micro-ADV was used for validation. As results, less than 15 degree in tilting angle generated much higher deviation, and higher yawing angle proportionally increased coefficient of variance. Yaw angles affected accuracy in terms of measurement area.