• Title/Summary/Keyword: vacuum tube

Search Result 236, Processing Time 0.024 seconds

Pinhole Phenomena in the External Electrode Fluorescent Lamps (외부전극 헝광램프의 핀홀 현상)

  • Gill, Doh-H.;Kim, Sang-B.;Song, Hyuk-S.;Yu, Dong-G.;Lee, Sang-H.;Pak, Min-Sun;Kang, June-Gill;Cho, Guang-Sup;Cho, Mee-R.;Hwang, Myung-G.;Kim, Young-Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.266-272
    • /
    • 2006
  • Application of power higher than the optimum operation value to an external electrode fluorescent lamps(EEFL) leads to the formation of small holes, called pinholes, which subsequently leads to lamp failure. The pinholes come from the insulating breakdown of the capacitor which is the dielectric layer between an external electrode and glass tube. The power of insulation breakdown is proportional to the electric power applied to the lamp. When a lamp current is low in the glass tube of dielectric constant K, the dielectric field strength of pinholes is about 3K kV/mm. The field strength of insulation breakdown decreases as the lamp current increases.

A X-ray Tube Using Field Emitter Made by Multi-walled Carbon Nanotube Yarns

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Kwak, Seung-Im;Ju, Jin-Young;Hwang, Yong-Gyoo;Lee, Choong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.392-392
    • /
    • 2011
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission.$^{1,2}$ CNT yarns have demonstrated its potential as excellent field emitters.$^3$ Extensive simulations were carried out in designing a CNT yarn-based cathode assembly. The focal spot size dependence on the anode surface of the geometric parameters such as axial distance of the electrostatic focus lens from the cathode and the applied bias voltages at the cathode, grid mesh and electrostatic focus lens were studied. The detailed computer simulations using Opera 3D electromagnetic software$^4$ had revealed that a remarkable size of focal spot under a focusing lens triode type set-up design was achieved. The result of this optimization simulation would then be applied for the construction of the CNT yarn based micro-focus x-ray tube with its field emission characteristics evaluated.

  • PDF

Synthesis of Double-walled Carbon Nanotubes Using Decomposition of Tetra Hydro Furan (Tetra Hydro Furan 열분해를 이용한 이중벽 구조 탄소나노튜브의 합성)

  • Kang, Ha-Na;Jung, Da-Mi;Sok, Jung-Hyun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.576-581
    • /
    • 2008
  • High-quality double-walled carbon nanotubes (DWNTs) were synthesized without defects and amorphous carbonaceous particles by catalytic decomposition method at $800^{\circ}C$ in high yield. As-synthesized carbon materials almost consist of DWNT bundles with a diameter 12 - 20 nm.. The DWNTs rope have uniform diameter about 2 - 5 um and length up to several tens micrometer. DWNTs is inner tube diameter 0.9 - 1.5 nm and outer tube 1.6 - 2.2 nm. We investigate the crystallinity of DWNTs by TEM and Raman spectroscopy. We also found that the Fe-Mo bimetallic catalyst was active as a very efficient catalyst for the synthesis of DWNTs with the catalyst decomposition method. Our results also indicate that Tetra Hydro Furan (THF) is a very ideal carbon source for the synthesis of DWNTs.

Blackening of Inner Glass Surface in Fluorescent Lamps for LCD Backlight (LCD 백라이트용 형광램프의 흑화 현상)

  • Hwang, Ha-Chung;Jeong, Jong-Mun;Kim, Jung-Hyun;Kim, Dong-Jun;Bong, Jae-Hwan;Chung, Jae-Yoon;Koo, Je-Huan;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.481-486
    • /
    • 2008
  • The different degrees of blackening were observed at the inner surface of borosilicate, soda-lime, and aluminosilicate glass tubes having different sodium (Na) contents. The sodium contents ($Na_2O$) within the borosilicate, soda-lime, and aluminosilicate glass tubes were found to be 4%, 14%, and 0.06%, respectively. The degree of blackening was shown to increase as the sodium content within the glass of the fluorescent lamp containing Ne+Ar+Hg gas mixture. Higher degree of blackening was observed from the inner surface of the glass tube coated with $Y_2O_3$. The blackening was found to be originated from the amalgam of $NaHg_2$ generated by the chemical reaction between the mercury ions within the discharge gas and sodium within the glass tube during operation.

in Vitro Embryo Production Following Transvaginal Follicular Oocyte Aspiration from Holstein Cows Using a Simple Aspiration Apparatus (간이 난자채취기를 이용한 젖소로부터 난초란의 채취와 체외수정란의 생산)

  • 김일화;손동수;이호준;이동원;최선호;서국현;양병철;이광원
    • Journal of Embryo Transfer
    • /
    • v.12 no.1
    • /
    • pp.111-116
    • /
    • 1997
  • The present study was carried out to produce in vitro fertilized embryos with immature follicular oocytes collected by transvaginal aspiration from Holstein cows. A simple aspiration apparatus consists of two stainless steel tubes, an inner tube (needle holder; 1.2cmdiameter, 55cm long) and an outer tube (1.5cm diameter, 4Scm long), and a hand-operated vacuum pump was used. Under epidural anesthesia, the needle guide was passed into the vagina of the cow to a point next to the cervix. An ovary was placed against the wall of the vagina over the end of the aspiration needle by rectal manipulation. As the needlepassed into the ovary, an assistant was asked to apply vacuum(l00mrnHg) and the ovary was manipulated back and forth in all directions over the needle. When all sites of the ovary was aspirated, the needle was withdrawn and the needle guide was moved to the other side of ovary and the procedure was repeated. When the oocyte aspiration procedure was finished, collected fluid was transported to laboratory. Oocytes surrounded with at least 1 layer of cumulus cells were matured, fertilized and cultured in vitro. The results were as follows; Ninety seven oocytes were collected by transvaginal aspiration from seventeen Holstein cows(5.7 /head). The number of oocytes surrounded with at least 1 layer of cumulus cells were 60(61.9%). Following in vitro maturation, fertilization and culture, the cleavage and development rate to morula+blastocyst were 83.3% and 30.0%, respectively. From this study, transferable in vitro fertilized embryos could be produced with imma- ture follicular oocytes collected by transvaginal aspiration from Holstein cows using a simple aspiration apparatus.

  • PDF

Microcomputer Based Vacuum Drying System and its Application to the Vacuum Drying of Green Red Pepper (마이크로컴퓨터 감압건조(減壓乾燥)시스템의 제작운영(製作運營)과 풋고추의 감압건조특성(減壓乾燥特性))

  • Chun, Jae-Kun;Kang, Jun-Soo
    • Applied Biological Chemistry
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 1987
  • In Girder to measure the pressure and weight decrease of drying sample during the vacuum drying process of food, sensing devices were designed and constructed with strain gauge. Microcomputer based vacuum drying system was made up of these devices interfaced to apple II microcomputer. The electrical output signal from vacuum sensor which constituted with Bourdon tube whereon strain gauge attached were digitalized and input to microcomputer through the MC 6821 interface I.C. chip. The relationship between read-out digital value (D) from microcomputer and readings of vacuum gauge (P, mmHg) was P=-146.136+3.620D'(r=0.9994) The pressure control of vacuum dryer was successfully conducted in the range of $400{\sim}600\;mmHg$ accuracy. The digitalized load cell output (D) could be correlated with the real weight (W, g) as W=-14,000+0.585D (r=0.9998) Drying curves of green red pepper under $64^{\circ}C$, $400{\sim}600\;mmHg$ was similar to those of red pepper and differently affected by the degree of vacuum pressure but was varied according to their shape (cut or whole). Moisture movement of green red pepper during the vacuum drying process was fitted to Page model. The empirical equations obtained were $M-M_e/M_o-M_e={\exp}\;(-0.0673{\theta}^{1.177})$ and $M-M_e/M_o-M_e={\exp}\;(-0.0655\;{\theta}^{1.477})$ for whole and cut green red pepper, respectively.

  • PDF

The Study on the Production Method of Stepwise Dilution Gas for Odor Analysis with Orifice Tubes (오리피스 튜브에 의한 단계별 냄새 분석용 희석가스의 제조방법에 관한 연구)

  • Kim, Han-Soo;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • This study is to develop the production method of stepwise dilution gas for the evaluation of complex odor concentration by orifice tube. The basic orifice tube for 10 and 30 times of dilution sample was made at first, and with the combination of the basic orifice tubes we can continuously manufacture the stepwise dilution sample gas for air dilution sensory test ; 10, 30, 100, 300, 1,000, 3,000 times etc. The hole size of orifice tube was 0.84 mm for 10 times of dilution sample, and was 0.34 mm for 30 times. Dilution sample gas made with the basic orifice tube have an excellent reproducibility, 2%RSD. In addition, over 90% of correlation was shown between the sample made by the orifice tube and the sample by the syringe dilution method. Because there was no concentration drift of dilution gas with changes of connected pump flow, the basic orifice tube could be mounted directly with a vacuum suction box, and could be used simply as a tool for the evaluation of odor, especially on site.

Development of a Semi-automatic Seeder with Vacuum Nozzles of Quadratic Arrangement for Small-sized Seeds (소립종자용 평면배열 진공노즐식 반자동 파종기 개발에 관한 연구)

  • Kim, Dong-Eok;Lee, Gong-In;Kang, Dong-Hyeon;Kim, You-Ho;Lee, Hye-Jin;Kim, Hyeon-Hwan;Kim, Jong-Ku;Kim, Yong-Hyeon
    • Journal of Biosystems Engineering
    • /
    • v.36 no.6
    • /
    • pp.434-443
    • /
    • 2011
  • A large scale seeding system was stable in terms of techniques but a convenient seeding system of small size was unsettled. This study was performed to develop a semi-automatic seeder for small and medium sized scale farm. To investigate optimum needle diameter and vacuum pressure was used vacuum suction needle seeder. Although the needle diameter according to the kinds of seed was different, the needle diameter for salvia and lettuce seed was suitable for 0.34 mm needle nozzle and 0.4 mm taper nozzle. The prototype consisted a seeding frame attached with needle nozzle, seed hopper, vibrating device, seeding part, vacuum ejector, seed tube etc.. As the result with the experiments, the seeding rate of the seeder was 92% and more at 0.34 mm diameter needle nozzle and 0.4 mm taper nozzle. Eccentric weight for seed hopper vibration was suitable that weight is 11 g and eccentric distance is 0.5 mm. Vibration acceleration of upward direction was 0.363 m/$s^2$. Working capacity of the seeder was possible 160 trays per hour. It was possible for sowing small seeds but it was required to make compact and simple model.

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

A Study on Design of Vacuum Silo for Batch Treatment System for Dredged Soil (준설토 일괄처리시스템을 위한 진공사이로 설계에 관한 연구)

  • Kim, Yong-Seok;Yang, Hae-Rim;Kim, Hac-Sun;Jeoung, Chan-Se;Yang, Soon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2012
  • In this study, a small movable batch treatment system for dredging soil deposited in a rain water tube is proposed; further, a vacuum silo sorting separation device with a vacuum silo, first-stage sorting separator, and conveyor is designed. The vacuum silo sorting separation device also consists of a storage tank, transferring screw, vacuum gate, screen bar, screen bar cleaner, and vacuum discharging device. In view of the fact that the flow of drawn air in the storage tank is a major factor influencing the sorting separation performance, the optimum shape of the tank is determined by CFD flow analysis. In addition, by using CAE structure analysis, the safety of a storage tank made of boards is examined. The specifications of the vacuum silo sorting separation device are determined by conducting mechanical and dynamic simulations of the driving mechanism of the vacuum silo sorting separation device through 3D-CAD modeling. Following this study, we will design a drum-screen-type second sorter, a decanter-type dehydration device, and waste water tank and pump as a secondary device. Further, on the basis of this design, we will construct a prototype model and carry out a field test.