• 제목/요약/키워드: vacuum pressure

검색결과 1,606건 처리시간 0.03초

수치해석에 의한 진공다이캐스팅에서의 용탕 유동특성 연구 (A study on Characteristics of Molten Metal Flow in Vacuum DieCasting by Numerical Analysis)

  • 박진영;임관우;이광학;김성빈;김억수;박익민
    • 한국주조공학회지
    • /
    • 제27권4호
    • /
    • pp.153-158
    • /
    • 2007
  • Molten metal flow in vacuum die casting was characterized by a numerical analysis. The VOF method was used to simulate the filling behaviors of molten metal during filling process. The various vacuum degrees of no vacuum(760 mmHg), 650, 500, 250 and 60mmHg were artificially applied in cavity. And the filling behaviors of molten metal with the applied vacuum conditions were simulated and compared with those of experiment. The results showed that molten metal was partially filled into cavity when vacuum was applied and the filling length of molten metal in cavity was increased with increasing applied reduced pressure in cavity. Also, the simulated filling behaviors of molten metal were apparently similar to those of experiment, indicating the numerical analysis developed in this study was highly effective. Through the result of fluid flow simulation, both relation equations of filling length and filling velocity with the variation of pressure conditions in cavity were calculated respectively and the internal gas contents of casting was significantly reduced by the modification of vacuum gate system.

$10^{-10}$ torr까지의 초고진공 표준 확립 (Establishment of Ultrahigh Vacuum Standard down to $10^{-10}$ torr Range)

  • 홍승수;임재영;박재홍;신용현;이철로;정광화
    • 한국진공학회지
    • /
    • 제2권2호
    • /
    • pp.139-144
    • /
    • 1993
  • 동적교정방법을 이용하여 $10^{-7}~10^{-10}$torr 영역에서 교정 가능한 초고진공 표준기를 제작하였다. $10^{-6}~10^{-9}$torr L/s 영역의 극미세 유량은 고진공 표준기에 porous plug를 연결하여 발생 제어시켰으며 일정한 배기속도를 유지함이 알려져 있는 refrigerator type cryopump를 이용하여 $3{\times}10^{-11}$torr의 base pressure를 얻을 수 있었다. 이 초고진공 표준기를 이용하여 두 개의 extractor gauge와 자체 제작한 nude 이온게이지들을 교정하고 그 직선성 및 재현도를 살펴보았다.

  • PDF

Evaluation of Effectiveness of Vacuum Oral Cleaner Developed for Patients with Limited Mobility

  • Lee, Jae-Hyun;Jung, Ki-Won;Kim, Hee-Kyung;Koo, Ki-Tae;Kim, Sung-Hun
    • 대한치과의사협회지
    • /
    • 제54권12호
    • /
    • pp.1035-1044
    • /
    • 2016
  • Purpose : The purpose of this study was to compare the plaque removal effects of vacuum oral cleaner developed for the patients with limited mobility with those of manual toothbrushes and high pressure injection oral cleaner (dental water jet). Meterials and methods : Thirty human subjects were measured with Patient Hygiene Performance index (PHP index) and O'Leary index before and after the use of toothbrush, high pressure injection oral cleaner and vacuum oral cleaner. These three different oral hygiene methods were conducted with seven-day intermittence. Then the statistical analysis was carried out to define plaque removal rate of three different oral hygiene methods (${\alpha}=.05$). Results : According to the efficacy analysis of plaque removal before and after the oral cleaning using each of three methods, significant reduction in plaque after the treatment compared to the previous state when using toothbrush, high pressure injection oral cleaner, and vacuum oral cleaner was observed (P < 0.001). PHP index of tooth brushing was higher than that of the high pressure injection oral cleaner, while PHP index of vacuum oral cleaner did not show significant difference from either of the other two methods. There was no significance difference in O'Leary index among the three methods. Conclusion : Effect of plaque removal using the vacuum oral cleaner is comparable to that of manual tooth brush or high pressure injection oral cleaner, so it will be helpful for self-oral hygiene care of the patients with limited mobility.

  • PDF

배수재의 직경과 형상변화가 수평진공배수에 미치는 영향 (Effects of Size and Shape of Drain on Horizontal Vacuum Drain)

  • 유남재;박병수;정길수;이병곤
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

Effect of membrane deformation on performance of vacuum assisted air gap membrane distillation (V-AGMD)

  • Kim, Yusik;Choi, Jihyeok;Choi, Yongjun;Lee, Sangho
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.51-62
    • /
    • 2022
  • Vacuum-assisted air gap membrane distillation (V-AGMD) has the potential to achieve higher flux and productivity than conventional air gap membrane distillation (AGMD). Nevertheless, there is not much information on technical aspects of V-AGMD operation. Accordingly, this study aims to analyze the effect of membrane deformation on flux in V-AGMD operation. Experiments were carried out using a bench-scale V-AGMD system. Statistical models were applied to understand the flux behaviors. Statistical models based on MLR, GNN, and MLFNN techniques were developed to describe the experimental data. Results showed that the flux increased by up to 4 times with the application of vacuum in V-AGMD compared with conventional AGMD. The flux in both AGMD and V-AGMD is affected by the difference between the air gap pressure and the saturation pressure of water vapor, but their dependences were different. In V-AGMD, the membranes were found to be deformed due to the vacuum pressure because they were not fully supported by the spacer. As a result, the deformation reduced the effective air gap width. Nevertheless, the rejection and LEP were not changed even if the deformation occurred. The flux behaviors in V-AGMD were successfully interpreted by the GNN and MLFNN models. According to the model calculations, the relative impact of the membrane deformation ranges from 10.3% to 16.1%.

Epi poly를 이용한 MEMS 소자용 웨이퍼 단위의 진공 패키징에 대한 연구 (A Study on Wafer Level Vacuum Packaging using Epi poly for MEMS Applications)

  • 석선호;이병렬;전국진
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.15-19
    • /
    • 2002
  • A new vacuum packaging process in wafer level is developed for the surface micromachining devices using glass silicon anodic bonding technology. The inside pressure of the packaged device was measured indirectly by the quality factor of the mechanical resonator. The measured Q factor was about 5$\times10^4$ and the estimated inner pressure was about 1 mTorr. And it is also possible to change the inside pressure of the packaged devices from 2 Torr to 1 mTorr by varying the amount of the Ti gettering material. The long-term stability test is still on the way, but in initial characterization, the yield is about 80% and the vacuum degradation with time was not observed.

  • PDF

대형 LNG선 주냉각기 해수라인의 부압현상 해석에 관한 연구 (A Study on the Analysis of a Negative Pressure in the Seawater Line of a Main Centeral Cooler (MCC) for a Large LNG Ship)

  • 김창복;사공운곤;김종규;김충식;송영호;최순호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.893-900
    • /
    • 2008
  • The heat exchangers in the ships have been changed from the conventional shell & tube type to the plate type due to some merits as a compactness, a high thermal efficiency and a light-weight. In recent. it is reported that the vacuum phenomena were occurred in the seawater outlet piping of a main central cooler (MCC) on the ships. From the viewpoints of a common sense, the vacuum pressure in the seawater piping is rare event and difficult to be convinced because the seawater is pumped into the piping by a seawater pump with a high discharge head. However, the occurrence of a vacuum pressure in the seawater line of an MCC is real situation and often gives a severe damage to a rubber gasket of an MCC with a plate type heat transfer area. In this study, we analyzed the vacuum pressure in the seawater line of an MCC by using the simpl Bernoulli's equation and found that the vacuum pressure in the seawater line of an MCC is inevitable untill the installation postion of an MCC is not lowered.

교류전압하에서 저압 진공관의 방전현상 (Discharge Phenomena of Low Pressure Vacuum under AC Applied Voltage)

  • 전진;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2301-2302
    • /
    • 2008
  • We experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and SF6. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

Vacuum Test of Cavity with Liquid Nitrogen

  • Choi, Suk;Park, Gunn-Tae;Kim, Heetae
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.132-135
    • /
    • 2015
  • Schematic of RAON vacuum system is introduced. Vacuum test for superconducting cavity with liquid nitrogen is performed. Schematic plan for RAON vacuum system is introduced and vacuum control system for superconducting cavity test is constructed. Vacuum pressure of cavity is shown as a function of pumping time. The temperature of cavity is shown as a function of cooling time. Outgassing species from cavity is also detected. Detailed experimental procedure is presented to test the cavity vacuum with liquid nitrogen.

대기압 플라즈마와 응용 (Atmospheric Plasma and Its Applications)

  • 엄환섭
    • 한국진공학회지
    • /
    • 제15권2호
    • /
    • pp.117-138
    • /
    • 2006
  • 지표면에서 플라즈마는 전기방전에 의하여 만들어낸다. 그래서 대부분의 플라즈마 발생은 1백만분의 1기압보다 더 낮은 기압에서 발생하고 있었다. 그러나 많은 플라즈마 응용은 고기압에서 발생한 플라즈마를 요구하고 있다. 진공펌프와 같은 고가의 장비를 피하기 위하여 과학자들은 1기압이나 그이상의 압력에서 플라즈마를 발생하는 연구를 하기 시작했다. 많은 량의 제료 공정, 환경보호와 개선, 그리고 고효율 에너지 창출과 이용 등의 분야에 플라즈마를 사용할 때에는 오직 더 많은 량의 플라즈마를 더욱 값싸게 만들 때에만 가능한 것이다. 우리는 따라서 고기압에서 플라즈마를 만들어내는 새로운 방법을 개발하고 이러한 플라즈마가 21세기 산업에 적용될 수 있는 새로운 기반을 구축하는 연구를 수행하고 있다. 이러한 기술은 미래의 재료 공정이나, 환경 그리고 에너지 분야에 지대한 영향을 미칠 것으로 생각한다.