• Title/Summary/Keyword: vacuum pressure

Search Result 1,610, Processing Time 0.03 seconds

Parameter Study for the Analysis of Impact Characteristics considering Dynamic Material Properties (동적 물성치를 고려한 V.I. 충격인자의 영향 분석)

  • Lim, J.H.;Song, J.H.;Huh, H.;Park, W.J.;Oh, I.S.;Choe, J.W.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.945-950
    • /
    • 2001
  • Vacuum interrupters that is used in various switchgear components such as circuit breakers, distribution switches, contactors, etc. spreads the arc uniformly over the surface of the contacts. The electrode of vacuum interrupters is used sintered Cu-Cr material satisfied with good electrical and mechanical characteristics. Because the closing velocity is 1-3m/s, the deformation of the material of electrodes depends on the strain rate and the dynamic behavior of the sintered Cu-Cr material is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain-rate is obtained from the split Hopkinson pressure bar test using cylinder type specimens. Experimental results from both quasi-static and dynamic compressive tests with the split Hopkinson pressure bar apparatus are interpolated to construct the Johnson-Cook equation as the constitutive relation that should be applied to simulation of the dynamic behavior of electrodes. To evaluate impact characteristic of a vacuum interrupter, simulation is carried out with five parameters such as initial velocity, added mass of a movable electrode, wipe spring constant, initial offset of a wipe spring and virtual fixed spring constant.

  • PDF

Design and Performance Evaluation of the Precision Pressure Control System for the High Vacuum Transport Module (고진공 운송계에서의 정밀 압력제어장치의 설게 및 성능시험)

  • Jang, W.I.;Jang, K.H.;Lee, J.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.92-98
    • /
    • 1995
  • In the cluster tool, it is necessary to precisely control the vacuum pressure for the wafer transportation between transport module and cassette or process modules with the range of 1*10$^{-4}$ to 5*10$^{-5}$ torr. So we have designed the pressure control system for the transport module of the cluster tool and have evaluated its performance. Digital PID is utilized with the weighted sum of both three previous errors and one current error. The feedback signal is put into the nitrogen mass flow controller using the transport module controller. This pressure control system can prevent the transport module from the particle generation and backstreaming of hazardous process gases of the process chamber.

  • PDF

The Influence of Radiation Trapping on the Metastable Population Density and Applications to Low-pressure Plasma

  • Lee, Yeong-Gwang;O, Se-Jin;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.245-246
    • /
    • 2011
  • Emission lines ratios were used for diagnostics of and excited level densities in low-temperature plasmas. In this work, an optical emission spectroscopy (OES) was used to determine the electron temperature and metastable level densities in low-pressure inductively coupled plasma. The emission spectroscopy method was based on a simple collisional-radiative model. The selected lines of the Ar(4p to 4s) were influenced by the radiation trapping at relatively high pressures where the plasma become optically thick. To quantify this effect, a pressure dependence factor ${\alpha}$(P) was derived by using corrections for the measured intensities. It was found that the lower metastable level densities were obtained when ${\alpha}$(P) increased with the increasing discharge pressure. The effect of non-Maxwellian electron energy distribution functions (EEDFs) on the metastables was also presented and discussed.

  • PDF

Pressure Measurement Using Field Electron Emission Phenomena

  • Cho, Boklae
    • Applied Science and Convergence Technology
    • /
    • v.23 no.2
    • /
    • pp.83-89
    • /
    • 2014
  • Adsorption of residual gas molecules damped the emission current of a W (310) field electron emission (FE) emitter. The damping speed was linearly proportional to the pressure gauge readings at pressure ranging from ${\sim}10^{-8}Pa$ to ${\sim}10^{-9}Pa$, and the proportionality constant was employed to measure pressure in the $10^{-10}Pa$ range. A time plot of FE current revealed the existence of an "initial stable region" after the flash heating of W(310) FE, during which the FE current damps very slowly. The presence of non-hydrogen gas removed this region from the plot, supplying a means of qualitatively analysing the gas species.

A Study on Panel Manufacture and Packaging Method for Digital FED (디지털 FID용 패널제작과 패키 방법에 관한 연구)

  • Kim, Soo-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.29-35
    • /
    • 2009
  • Field emission displays(FED) are currently being study as a potential flat technology. The purpose of this project shows the research result of vacuum packaging technology for the development of FED. For FED vacuum packaging, the bonding of glass/glass, the exhaust of vacuum and getter technology have been studied for vacuum packaging technology The simulation and vacuum sealing, and glass/glass bonding are also extensively studied. The glass/glass bonding is formed by using the frit glass and the Inside pressure of complete panel showed of $2{\times}10^{-5}$[Torr]. As a getter result, the increase of pressure has been showed the decrease of outgassing effect by using thin film getter.

Performance Improvement of a Vacuum Cleaner by CFD Analysis around Motor (진공청소기 흡입효율 개선을 위한 모터 주위의 유동해석)

  • Park, J.W.;Ki, M.C.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.522-525
    • /
    • 2008
  • A vacuum cleaner is the widely used home equipment. However, it has a trouble with too much power consumption. Most losses occur at the centrifugal fan. To remedy this trouble the investigation of motor, which is the main component of vacuum cleaner, is required. The flow characteristics around the high-speed rotating centrifugal fan which is influenced by the very low inlet pressure is quite different from a commonly used fan. Hence it is quite difficult to analyze the flow by the experimental means or by the numerical simulation. In this research, it is aimed to improve the air-suction performance of a vacuum cleaner through the flow analysis around a motor. The efficiency of the centrifugal fan is affected by blade shape, blade number, blade pitch, etc. The influence of the shape of impeller on the flow is investigated in this study. The flow around the centrifugal fan is simulated by applying the moving mesh. To verify the validity of the computation results, the air flow rate and the pressure field to the cleaner is compared with the experimental data. All simulations are performed by using commercial code SC/Tetra. The calculated results show good agreement with the experimental ones and it is believed to be promising to use computational simulation in the improvement of the vacuum cleaner performance.

  • PDF

Comparison of the Quality of Frozen Skipjack Tuna Katsuwonus pelamis Thawed by Vacuum and Water Immersion (진공 해동과 침수 해동에 의한 냉동 가다랑어(Katsuwonus pelamis)의 품질 차이에 관한 연구)

  • Lee, Tae-Hun;Koo, Jae-Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.6
    • /
    • pp.635-639
    • /
    • 2012
  • Thawing is very important in tuna canning because it affects the yield and quality of the canned tuna, and productivity. The effects of vacuum thawing on the quality, yield, and thawing times of frozen skipjack were compared with conventional water immersion thawing. The time required to thaw frozen skipjack tuna (weight 2.5-3.0 kg) from $-10^{\circ}C$ to $-2^{\circ}C$ was 75, 60, and 37 min at a pressure of 17, 23, and 31 mmHg, respectively, corresponding to temperatures of 20, 25, and $30^{\circ}C$. The thawing time decreased with increasing pressure. Vacuum thawing shorten the thawing time by 58-80% compared with water immersion thawing at $20^{\circ}C$, and there was less difference between the core and skin temperatures than with water immersion thawing. No significant change in pH or histamine was observed according to thawing method, while the volatile basic nitrogen (VBN), trimethylamine (TMA), and K value were lower with vacuum thawing than water immersion thawing. Based on these results, we believe that vacuum thawing minimizes the biochemical and microbial changes that occur while thawing frozen skipjack tuna.

Development of a Housing Component for an Auto-compressor Using Vacuum Ladling Die Casting (진공급탕식 다이캐스팅법을 이용한 자동차 콤프레서용 하우징 부품 개발)

  • Lee, H.S.;Park, J.S.
    • Transactions of Materials Processing
    • /
    • v.21 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • A vacuum ladling die casting system is suggested as a means to obtain a high vacuum level. A high vacuum of 17.8 mmHg is obtained by sealing the inner space of the mould. The sample product is a rear-head housing for an auto-compressor, and the die-casting with 6-cavities was conducted. The flow analysis shows that the filling speed during vacuum ladling is faster than for a non-vacuum system. The air holes in the sample product were too small to be seen with the naked eye in X-ray films. Density tests show that the high vacuum ladling system reduces the internal porosity as much as 57.8% when compared to the non-vacuum system. A defective rate of only 0.17% was found from leak testing. The results of this research prove that the high vacuum die-casting process is useful for manufacturing of aluminium components under high internal pressure.