• Title/Summary/Keyword: vacuum concentration

Search Result 658, Processing Time 0.03 seconds

Changes of Chemical Species in Soil Solution Induced by Heavy Metals (중금속이 토양용액 중 화학종 변화에 미치는 영향)

  • Yang, Jae-E.;Lee, Ki-Won;Kim, Jeong-Je;Lim, Hyung-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.14 no.3
    • /
    • pp.263-271
    • /
    • 1995
  • Chemical assessment of soil pollution with heavy metals was made by analyzing the changes in pH, ionic strength, cationic concentration and chemical species in the soil solution. Saturated pastes of the unpolluted soils were made by adding solutions containing Cu or Cd and the final Cu or Cd concentrations were in the range of 0 to 400 mg/kg. After equilibrating for 24 hours at $25^{\circ}C$, the soil solution was extracted from the saturated pastes by the vacuum extraction method and analyzed for pH, electrical conductivity, Cu, Cd, cations and inorganic ligands. Chemical species in soil solution were calculated by the GEOCHEM-PC program employing the input variables of pH, ionic strength(${\mu}$), molar concentrations of cations and ligands. Increasing Cu or Cd additions lowered pH of the soil solution but increased concentrations of Ca, Mg and K resulting in increases of ${\mu}$ of the soil solution. Effects of Cu on lowering pH and increasing ${\mu}$ were greater than those of Cd. Concentrations of Cu or Cd in soil solution were relatively very low as compared to those of additions, but increased linearly with increasing additions representing that concentrations of Cu were higher than those of Cd. At 400 mg/kg additions, concentrations of Cu were in the range of 0.51 to 11.70 mg/L but those of Cd were 34.4 to 88.5 mg/L. Major species of Ca, Mg and K were free ions and these species were equivalent to greater than 95 molar % of the existing respective molar concentrations. These cationic species were not changed by Cu or Cd additions. Major species of Cu in lower pH soils such as SiCL and SL were free $Cu^{2+}$ (>95 molar %), but those in LS having a higher pH were free $Cu^{2-}$ and Cu-hydroxide complex. At 100 mg Cu/kg treatment, $Cu^{2+}$ and Cu-hydroxide complex were equivalent to 73 and 22.4 molar %, respectively. These respective percentages were decreased and increased correspondingly with increasing Cu treatments. Major species of Cd in soil solution were free $Cd^{2+}$ and Cd-chloride complex, representing 79 to 85 molar % for $Cd^{2+}$ and 13 to 20% for Cd-chloride complex at 10 mg Cd/kg treatment. With increasing Cd additions to 400 mg/kg, $Cd^{2+}$ species decreased to $40{\sim}47%$ but Cd-chloride complexes increased to $53{\sim}60$ molar %. These results demonstrated that soil contamination with heavy metals caused an adverse effect on the plant nutritional aspects of soil solution by lowering pH, increasing cations temporarily, and increasing free metal concentrations and species enough to be phytotoxic.

  • PDF

Suppressive Effects of the Extract of Zanthoxylum schinifolium and Essential Oil from Zanthoxylum piperitum on Pacific Saury, Coloabis saira Kwamegi (산초(Zanthoxylum schinifolium) 추출물과 초피(Zanthoxylum piperitum) 정유의 꽁치과메기 산패 억제 효과)

  • Cho, Sung-Hee;Kwon, Eun-Hye;Oh, Seung-Hee;Woo, Mi-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.12
    • /
    • pp.1753-1759
    • /
    • 2009
  • The present study was conducted to investigate the effects of components obtained from Zanthoxylum schinifolium and Zanthoxylum piperitum on rancidity and quality of Kwamegi (semi-dried Pacific saury, Coloabis saira). Ethanol extract (ZS) of Zanthoxylum schinifolium leaves or the essential oil (ZP) obtained from pericarp of Zanthoxylum piperitum in 1 or 20% ethanol solution was sprayed to the Pacific saury before Kwamegi preparation at its final concentrations of 0.125~2 ppm in the Kwamegi. The prepared Kwamegi was vacuum packed with multi-layered film (polyethylene/polyamide/EVOH/polyethylene, thickness 80 μm) and kept at -20${^{\circ}C}$ until use. After opening the package Kwamegi was stored at 4${^{\circ}C}$ for 1, 3 and 7 days during which rancidity tests and sensory evaluation were carried out. Acid, peroxide, and thiobarbituric acid (TBA) values increased with storage time but reduced significantly by the addition of ZS at the concentrations of ≥G0.125 ppm and ZP≥F0.25 ppm. The effects of ZS and ZP were dose-dependent and more pronounced as storage time prolonged. The ZS and ZP also reduced dimethyamine and trimethyamine (TMA) contents which were increased with time, while they prevented the decrease of trimethyamine oxide. The ZS at the concentration of ≥G0.25 ppm and the ZP at >0.5 ppm were needed to maintain TMA less than 4.5 mg/100 g for 3 day storage at 4${^{\circ}C}$. Sensory evaluation of the Kwamegi exhibited a slightly higher preference with the ZS and ZP treated ones at the level of 0.25~0.5 ppm. It is concluded that very low amounts of ZS and ZP are effective in suppression of rancidity of Kwamegi and could be utilized for its quality management.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Investigation on the Material and Migration Tests of Gas Impermeable Plastic Vacuum Packaging Materials for Food-Contact Use (식품용 합성수지제 공기차단성 포장재에서의 재질 및 용출시험량 조사)

  • Lee, Jung-Pyo;Lee, Youn-Kyu;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.14 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • Twenty eight gas impermeable plastic films for food-contact application were collected in the domestic market and material and/or migration tests for overall migration, antioxidants, potassium permanganate consumption, heavy metal, and plasticizers were carried out. The average overall migration values for NY/PE or NY/LLDPE, PETP/PE, and PVDC packaging films obtained by using n-heptane as fatty food simulant were 7.6, 6.9 and 14.1 mg/L, respectively. These values were much lower than the limit values of 150 and 30 mg/L for polyethylene and polyvinylidene chloride prescribed in the Korea Food Code. In almost of the packaging materials tested, the antioxidants such as Irganox 1010, Irganox 1076 and Irgafos 168 were found. The migration test result showed that almost of all samples except PVDC film contained Irganox 1076 and Irgafos 168, while the maximum migration value of Irganox 1076 into n-heptane was found in the Ny/PE/LLDPE(15/25/50 ${\mu}m$) sample at the concentration of 216.9 ${\mu}g/g$. From the plastic packaging samples tested, plasticizers such as DEP, DPRP, DBP, DPP, BBP, DCHP, DEHP, DEHA and observed above the detection limit. Consumption amount of potassium permanganate was much lower than the limit value of 10 mg/L. In the material test for heavy metals, cadmium and lead were determined at the concentrations far below the limit value of 100 mg/kg. The migration test for cadmium and lead showed a lower value than the detection limit. Therefore, it can be concluded that the safety status of the plastic films tested met the requirement of limit values as prescribed for the material and migration tests of food packaging utensils, containers and packages of the Korea Food Code.

  • PDF

Ni/Au Electroless Plating for Solder Bump Formation in Flip Chip (Flip Chip의 Solder Bump 형성을 위한 Ni/Au 무전해 도금 공정 연구)

  • Jo, Min-Gyo;O, Mu-Hyeong;Lee, Won-Hae;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.6 no.7
    • /
    • pp.700-708
    • /
    • 1996
  • Electroless plating technique was utilized to flip chip bonding to improve surface mount characteristics. Each step of plating procedure was studied in terms pf pH, plating temperature and plating time. Al patterned 4 inch Si wafers were used as substrstes and zincate was used as an activation solution. Heat treatment was carried out for all the specimens in the temperature range from room temperature to $400^{\circ}C$ for $30^{\circ}C$ minutes in a vacuum furnace. Homogeneous distribution of Zn particles of size was obtained by the zincate treatment with pH 13 ~ 13.5, solution concentration of 15 ~ 25% at room temperature. The plating rates for both Ni-P and Au electroless plating steps increased with increasing the plating temperature and pH. The main crystallization planes of the plated Au were found to be (111) a pH 7 and (200) and (111) at pH 9 independent of the annealing temperature.

  • PDF

Air Sampling and Isotope Analyses of Water Vapor and CO2 using Multi-Level Profile System (다중연직농도시스템(Multi-Level Profile System)을 이용한 수증기와 이산화탄소 시료채취 및 안정동위원소 조성 분석)

  • Lee, Dong-Ho;Kim, Su-Jin;Cheon, Jung-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.277-288
    • /
    • 2010
  • The multi-level $H_2O/CO_2$ profile system has been widely used to quantify the storage and advection effects on energy and mass fluxes measured by eddy covariance systems. In this study, we expanded the utility of the profile system by accommodating air sampling devices for isotope analyses of water vapor and $CO_2$. A pre-evacuated 2L glass flask was connected to the discharge of an Infrared Gas Analyzer (IRGA) of the profile system so that airs with known concentration of $H_2O$ and $CO_2$ can be sampled. To test the performance of this sampling system, we sampled airs from 8 levels (from 0.1 to 40 m) at the KoFlux tower of Gwangneung deciduous forest, Korea. Air samples in the 2L flask were separated into its component gases and pure $H_2O$ and $CO_2$ were extracted by using a vacuum extraction line. This novel technique successfully produced vertical profiles of ${\delta}D$ of $H_2O$ and ${\delta}^{13}C$ of $CO_2$ in a mature forest, and estimated ${\delta}D$ of evapotranspiration (${\delta}D_{ET}$) and ${\delta}^{13}C$ of $CO_2$ from ecosystem respiration (${\delta}^{13}C_{resp}$) by using Keeling plots. While technical improvement is still required in various aspects, our sampling system has two major advantages over other proposed techniques. First, it is cost effective since our system uses the existing structure of the profile system. Second, both $CO_2$ and $H_2O$ can be sampled simultaneously so that net ecosystem exchange of $H_2O$ and $CO_2$ can be partitioned at the same temporal resolution, which will improve our understanding of the coupling between water and carbon cycles in terrestrial ecosystems.

Two Crystal Structures of Dehydrated Calcium and Silver Exchanged Zeolite A, $Ag_{12-2x}Ca_x-A (x = 2.5 and 5.0)$ (칼슘 및 은 이온으로 치환한 제올라이트 A, $Ag_{12-2x}Ca_x-A (x = 2.5$$5.0)$ 의 탈수한 결정구조)

  • Seung Hwan Song;Jong Yul Park;Kim, Eun Sik;Yang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.452-458
    • /
    • 1989
  • The crystal structures of vacuum-dehydrated $Ag^+\;and\;Ca^{2+}$ exchanged zeolite A, Ag_7Ca_{2.5}-A(a = 12.310(1){\AA})$ and $Ag_2Ca_5-A(a = 12.287(2){\AA})$ have been determined by single-crystal X-ray diffraction methods in the cubic space group Pm3m at $21(1)^{\circ}C$. The crystals of $A_7Ca_{2.5}-A\;and\;Ag_2Ca_5-A$ were prepared by flow method using exchange solutions in which mole ratios of $AgNO_3\;and\;Ca(NO_3)_2$ were 1:50 and 1:1000, respectively, with total concentration of 0.05 M. Full-matrix least-squares refinement converged to the final error indices of R1 = 0.056 and R2 = 0.059 for $Ag7Ca2.5-A$, and R1 = 0.054 and R2 = 0.082 for $Ag2Ca5-A$ using 306 and 348 reflections, respectively, for which I >3 {\sigma}$ (I). 5.5 $Ag^+$ ions and 2.5 Ca^{2+}$ ions for $Ag_7Ca_{2.5}-A\;and\;2\;Ag^+$ ions and 5 $Ca^{2+}$ ions for $Ag_2Ca_5-A$ lie on two crystallographically nonequivalent threefold axes on the 6-rings. Both structures indicate that smaller Ca2+ ions preferentially occupy 6-ring sites and larger $Ag+$ ions occupy 8-ring sites when total number of cations per unit cell is more than 8.

  • PDF

Annealing Effect on Magnetic and Electrical Properties of Amorphous Ge1-xMnx Thin Films (비정질 Ge1-xMnx 박막의 전기적, 자기적 특성에 미치는 열처리 효과)

  • Lee, Byeong-Cheol;Kim, Dong-Hwi;Anh, Tran Thi Lan;Ihm, Young-Eon;Kim, Do-Jin;Kim, Hyo-Jin;Yu, Sang-Soo;Baek, Kui-Jong;Kim, Chang-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.3
    • /
    • pp.89-93
    • /
    • 2009
  • Amorphous $Ge_{1-x}Mn_x$ semiconductor thin films grown by low temperature vapor deposition were annealed, and their electrical and magnetic properties have been studied. The amorphous thin films were $1,000{\sim}5,000\;{\AA}$ thick. Amorphous $Ge_{1-x}Mn_x$ thin films were annealed at $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$ and $700^{\circ}C$ for 3 minutes in high vacuum chamber. X-ray diffraction analysis reveals that as-grown $Ge_{1-x}Mn_x$ semiconductor thin films are amorphous and are crystallized by annealing. Crystallization temperature of amorphous $Ge_{1-x}Mn_x$ semiconductor thin films varies with Mn concentration. Amorphous $Ge_{1-x}Mn_x$ thin films have p-type carriers and the carrier type is not changed during annealing, but the electrical resistivity increases with annealing temperature. Magnetization characteristics show that the as-grown amorphous $Ge_{1-x}Mn_x$ thin films are ferromagnetic and the Curie temperatures are around 130 K. Curie temperature and saturation magnetization of annealed $Ge_{1-x}Mn_x$ thin films increase with annealing temperature. Magnetization behavior and X-ray analysis implies that formation of ferromagnetic $Ge_3Mn_5$ phase causes the change of magnetic and electrical properties of annealed $Ge_{1-x}Mn_x$ thin films.