• Title/Summary/Keyword: v-ray

Search Result 2,499, Processing Time 0.037 seconds

Determination of Air-dry Density of Wood with Polychromatic X-ray and Digital Detector

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.836-845
    • /
    • 2017
  • Gravimetric method is usually used to evaluate air-dry density, which is governing physical or mechanical properties of wood. Although it had high evaluation accuracy, the method is time consuming process. Thus, this study was conducted to estimate air-dry density of wood with high accuracy by using polychromatic X-ray and digital detector as alternative of gravimetric method. To quantify polychromatic X-ray projection for evaluating air-dry density, Lambert-Beer's law with the integral value of probability function was used. The integral value was used as weighting factor in the law, and it was determined by conducting simple test at various penetration depths and tube voltage. Mass attenuation coefficient (MAC) of wood also calculated by investigating polychromatic X-ray projection according to species, penetration depth and tube voltage. The species had not an effect on change of MAC. Finally, an air-dry density of wood was estimated by applying the integral value, MAC and Lambert-Beer's law to polychromatic X-ray projection. As an example, the relation of the integral value (${\alpha}$) according to penetration depth (t, cm) at tube voltage of 35 kV was ${\alpha}=-0.00091t{\times}0.0184$ while the regression of the MAC (${\mu}$, $cm^2/g$) was ${\mu}=0.5414{\exp}(-0.0734t)$. When calculation of root mean squared error (RMSE) was performed to check the estimation accuracy, RMSE at 35, 45 and 55 kV was 0.010, 0.013 and $0.009g/cm^3$, respectively. However, partial RMSE in relation to air-dry density was varied according to tube voltage. The partial RMSE below air-dry density of $0.41g/cm^3$ was $0.008g/cm^3$ when tube voltage of 35 kV was used. Meanwhile, the partial RMSE above air-dry density of $0.41g/cm^3$ decreased as tube voltage increased. It was conclude that the accuracy of estimation with polychromatic X-ray and digital detector was quite high if the integral value and MAC of wood were determined precisely or a condition of examination was chosen properly. It was seemed that the estimation of air-dry density by using polychromatic X-ray system can supplant the gravimetric method.

Effects of substitution with La and V in $Bi_4Ti_3O_{12}$ thin film by MOCVD using ultrasonic spraying (초음파분무 MOCVD법에 의한 $Bi_4Ti_3O_{12}$ 박막의 제조와 La과 V의 Co-Substitution 에 의한 효과)

  • 김기현;곽병오;이승엽;이진홍;박병옥
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.6
    • /
    • pp.272-278
    • /
    • 2003
  • $Bi_4Ti_3O_{12}$ (BIT) and $(Bi_{3.25}La_{0.75})(Ti_{2.97}V_{0.03})O_{12}$ (BLTV) thin films were deposited on ITO/glass substrates by metal organic chemical vapor deposition (MOCVD) using ultrasonic spraying. After deposition of the films in oxygen atmosphere for 30 min, the films were heated by rapid thermal annealing (RTA) method, especially direct insertion, at various temperatures. The films were investigated on phase formation temperature, microstructure and electrical properties. From x-ray diffraction (XRD) patterns, the perovskite phase formation temperature of BLTV thin film was about $600^{\circ}C$ which was lower than that of BIT, $650^{\circ}C$. The leakage current of the BLTV thin film was measured to be $1.52\times 10^{-9}$A/$cm^2$ at an applied voltage of 1 V. The remanent polarization (Pr) and coercive field (Ec) values of the BLTV film deposited at $650^{\circ}C$ were $5.6\muC/cm^2$ and 96.5 kV/cm, respectively.

Electrochemical characteristics of Ca, P, Sr, and Si Ions from PEO-treated Ti-6Al-4V Alloy Surface

  • Yu, Ji-Min;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.154-154
    • /
    • 2017
  • Ti-6Al-4V alloys are widely used as metal-lic biomaterials in dentistry and orthopedics due to its excellent biocompatibility and me-chanical properties. However, because of low biological activity, it is difficult to form bone growth directly on the surface of titanium implants. For this reason, surface treatment of plasma electrolytic oxidation(PEO) was used for dental implants. To enhance bioac-tivity on the surface, strontium(Sr) and sili-con(Si) ions can be added to PEO treated sur-face in the electrolyte containing these ions. The presence of Sr in the coating enhances osteoblast activity and differentiation, where-as it inhibits osteoclast production and prolif-eration. And Si has been found to be essen-tial for normal bone, cartilage growth, and development. In this study, electrochemical characteristics of Ca, P, Sr, and Si ions from PEO-treated Ti-6Al-4V alloy surface was re-searched using various experimental instruments. DC power is used and Ti-6Al-4V al-loy was subjected to a voltage of 280 V for 3 minutes in the electrolyte containing 5, 10, 20M% Sr ion and 5M% Si ion. The morphol-ogies of PEO-treated Ti-6Al-4V alloy by electrochemical anodization were examined by field-emission scanning electron micro-scopes (FE-SEM), energy dispersive x-ray spectroscopy (EDS), x-ray diffraction (XRD) and corrosion analysis using AC impedance and potentiodynamic polarization test in 0.9% NaCl solution at similar body tempera-ture using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV.

  • PDF

Electrochemical Properties of Graphene-vanadium Oxide Composite Prepared by Electro-deposition for Electrochemical Capacitors (양극전착을 통한 그래핀-바나듐 산화물 복합체 제조 및 전기화학적 특성평가)

  • Jeong, Heeyoung;Jeong, Sang Mun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.131-136
    • /
    • 2015
  • The nanostructural graphene/vanadium oxide (graphene/$V_2O_5$) composite with enhanced capacitance was synthesized by the electro-deposition in 0.5 M $VOSO_4$ solution. The morphology of composites was characterized using scanning electron microscopy (SEM), x-ray diffraction pattern (XRD), and x-ray photoelectron spectroscopy (XPS). The oxidation states of the electro-deposited vanadium oxide was found to be $V^{5+}$ and $V^{4+}$. The morphology of the prepared graphene/$V_2O_5$ composite exhibits a netlike nano-structure with $V_2O_5$ nanorods in about 100 nm diameter, which could lead a better contact between electrolyte an electrode. The composite with a deposition time of 4,000 s exhibits the specific capacitance of $854mF/cm^2$ at a scan rate of 20 mV/s and the capacitance retention of 53% after 1000 CV cycles.

Extensive analysis of several Indian and Yemeni soils' gamma-ray shielding characteristics: An experimental and simulation approach

  • Shamsan S. Obaid;M.I. Sayyed;A.S. Alameen;D.K. Gaikwad;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3558-3565
    • /
    • 2024
  • The linear attenuation coefficients (LAC) of four soils (Black cotton (S1), Sandy (S2), Clay (S3), and Sandy (S4)) samples were measured at photon energies released from radioisotopes Co57 (122 keV), Ba133 (356 keV), 22Na (511 and 1275 keV), Cs137 (662 keV), Mn54 (840 keV), and Co60 (1330 keV) using a gamma spectrometer includes a NaI (Tl) scintillation detector. The experimental measurements were confirmed utilizing the Monte Carlo N-particle transport code. The linear attenuation coefficient values enhanced from 0.256 cm-1 to 0.296 cm-1 (at Eγ of 122 keV), from 0.126 cm-1 to 0.142 cm-1 (at Eγ of 662 keV), and from 0.0938 cm-1 to 0.105 cm-1 (at Eγ of 1275 keV), raising the (Fe + Mn) concentration from 0.912 wt% to 11.214 wt%, as well as raising the soil samples density from 1.62 g/cm3 to 1.79 g/cm3. The study also shows an enhancement in the half value thickness, transmission factor, radiation protection efficiency and lead's equivalent thickness due to the enrichment of Fe + Mn concentrations within the studied soils. The results show that the Black cotton soil exhibits better shielding properties for γ-ray than the other soils.

Laryngeal height and voice characteristics in children with autism spectrum disorders (자폐스펙트럼장애 아동의 후두 높이 및 음성 특성)

  • Lee, Jung-Hun;Kim, Go-Woon;Kim, Seong-Tae
    • Phonetics and Speech Sciences
    • /
    • v.13 no.2
    • /
    • pp.91-101
    • /
    • 2021
  • The purpose of this study was to investigate laryngeal characteristics in children with autism spectrum disorders (ASD). A total of 50 children participated, including eight children aged 2 to 4 years old diagnosed with ASD and 42 normal controls at the same age. All children recorded X-ray images of the midsagittal plane of the cervical spine and larynx, and compared the laryngeal positions of ASD and control. In addition, samples of children with vowel prolongation were collected and analyzed for acoustic parameters. X-rays showed that the height of the hyoid bone in the normal group was the lowest at 3 years of age, and ascended at 4 years of age. Nevertheless, the distance from the external acoustic meatus to the hyoid bone was longest at age 4. 4-year-olds with explosive language development showed laryngeal height elevation and anteriorization. In contrast, the hyoid height of the ASD group of all ages was lower than that of the control group, and there was no difference in the hyoid position between the ages. As a result of acoustic evaluation, PFR, vFo, and vAm were significantly higher ASD than control. Low laryngeal height of ASD children may be associated with delayed language development. PFR, vFo, and vAm seem to be voice markers showing the difference between normal and ASD children.

Effect of P(VDF/TrFE) Film Thickness on the Characteristics of Pyroelectric Passive Infrared Ray Sensor for Human Body Detection (P(VDF/TrFE) 필름의 두께에 따른 인체 감지형 초전형 PIR 적외선 센서의 특성)

  • Kwon, Sung-Yeol
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.114-117
    • /
    • 2011
  • A thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated and then thin 1.6 ${\mu}m$ thickness P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated also. These thick and thin P(VDF/TrFE) film pyroelectric infrared ray sensor was mounted in TO-5 housing to detect infrared light of 5.5 ~ 14 ${\mu}m$ wavelength for human body detecting with each other. The noise output voltage of the thick P(VDF/TrFE) film pyroelectric infrared ray sensor were 380 mV and NEP(noise equivalent power) is $3.95{\times}10^{-7}$ W which is the similar value with the commercial pyroelectric infrared ray sensor using ceramic materials as a sensing material. The NEP and specific detectivity $D^*$ of the thin P(VDF/TrFE) film pyroelectric infrared ray sensor were $2.13{\times}10^{-8}$ W and $9.37{\times}106$ cm/W under emission energy of 13 ${\mu}W/cm^2$ respectively. These result caused by lower thermal diffusion coefficient of a thin 1.6 ${\mu}m$ thickness PVDF/TrFE film than the thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor.

Studies on Inorganic Chinese Drugs in Korea (V) Study on Yung-Sa (Vermillion) (광물성한약에 관한 연구 (V) 영사에 관한 연구)

  • 이은옥
    • YAKHAK HOEJI
    • /
    • v.13 no.2_3
    • /
    • pp.93-96
    • /
    • 1969
  • X-ray diffraction analysis of Yung-Sa, an inorganic chinese drug in Korea, revealed the following: 1. "Yung-Sa" is red mercuric sulfide crystal (Vormillion) which is cinnabar type of hexagonal system. 2. It is accurate to call "Yung-Sa" synthetic red mercuric sulfide. 3. "Chung-Sa-Du" is mixture of crystals of cinnabar and meta-cinnabar types.

  • PDF