• 제목/요약/키워드: utility estimation

검색결과 171건 처리시간 0.039초

Experimental Optimal Choice Of Initial Candidate Inliers Of The Feature Pairs With Well-Ordering Property For The Sample Consensus Method In The Stitching Of Drone-based Aerial Images

  • Shin, Byeong-Chun;Seo, Jeong-Kweon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권4호
    • /
    • pp.1648-1672
    • /
    • 2020
  • There are several types of image registration in the sense of stitching separated images that overlap each other. One of these is feature-based registration by a common feature descriptor. In this study, we generate a mosaic of images using feature-based registration for drone aerial images. As a feature descriptor, we apply the scale-invariant feature transform descriptor. In order to investigate the authenticity of the feature points and to have the mapping function, we employ the sample consensus method; we consider the sensed image's inherent characteristic such as the geometric congruence between the feature points of the images to propose a novel hypothesis estimation of the mapping function of the stitching via some optimally chosen initial candidate inliers in the sample consensus method. Based on the experimental results, we show the efficiency of the proposed method compared with benchmark methodologies of random sampling consensus method (RANSAC); the well-ordering property defined in the context and the extensive stitching examples have supported the utility. Moreover, the sample consensus scheme proposed in this study is uncomplicated and robust, and some fatal miss stitching by RANSAC is remarkably reduced in the measure of the pixel difference.

건물 바닥 구조 해석 모드의 튜닝 (Estimation of the Dynamic Load of the Utility in Building by TPA Method)

  • 정민기;권형오;김효범;이정하;이상엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.441-446
    • /
    • 2008
  • The source transfer receiver model ('Source $\times$ Transfer = Response' model) which is widely used by NVH development process of vehicle/transport/machinery to analyze effectively and manage efficiently the structural dynamic behavior is also applicable to construction structure. If the evaluation assessment of the vibration level does not meet the target level, there are two methods, one is source treatment or replacement and the other is the reduction treatment on the transfer structure. In case of source treatment, it is done by source supplier and so, the latter is more practical method to reduce the vibration level. In this study, in order to get the accurate Transfer FE model(floor structure FE model), Experimental modal analysis of part of floor structure and FEM modal analysis of full floor structure are performed, then updating of FE model is performed after correlation analysis between these two results and finally, the modal model and FRF are compared between FE and Experimental results.

  • PDF

분산전원이 설치 된 배전 계통의 분포부하를 이용한 IVVC알고리즘 (Integrated Voltage/Var control based on Distributed Load Modeling with Distributed Generation in Distribution System)

  • 김영인;임일형;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.95_96
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load with Distributed Generation and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

  • PDF

배전계통의 분포 부하 모델링을 통한 최적화 IVVC 알고리즘 (Integrated Volt/Var Control Algorithm based on the Distributed Load Modeling of Distribution Network)

  • 김영인;임일형;최면송;이승재;이성우;권성철
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1463-1471
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

고등어 표피의 미생물 오염도 신속측정을 위한 ATP Bioluminescence assay (Application of ATP Bioluminescence Assay for a Rapid Estimation of Microbial Levels in Mackerel(Scomber japonicus))

  • 오세욱;조진호;이남혁
    • 한국식품과학회지
    • /
    • 제31권5호
    • /
    • pp.1345-1348
    • /
    • 1999
  • 고등어의 저장중 표피 오염 미생물 수를 신속하게 측정하여 신선도 판정을 위한 자료로 활용하고자 ATP bioluminescence assay에 의한 측정가능성을 파악하고자 하였다. 고등어를 $1^{\circ}C$에 저장하면서 표피를 swabbing 방법에 의해 미생물을 분리하여 총균수의 변화와 ATP bioluminescence assay에 의한 RLU 값을 측정하여 상관관계를 측정하여 본 결과 0.90 이상의 regression coefficient를 나타내어 유의적인 관계가 있음을 알 수 있었다. 따라서 ATP bioluminescence assay는 고등어 표피 오염 미생물의 신속 측정 방법으로 적합함을 알 수 있었으며 이 방법을 사용하였을 경우 기존의 48시간 이상 소요되는 전통적인 plate count 방법에 비하여 전처리를 포함하여 30분 이내에 결과를 알 수 있는 매우 신속하고 정확한 측정방법임을 알 수 있었다.

  • PDF

Effect of Arrangement of Design Elements on Recognition of Complex Signs

  • Ishihara, Maki;Okada, Akira;Yamashita, Kuniko
    • 대한인간공학회지
    • /
    • 제26권4호
    • /
    • pp.143-146
    • /
    • 2007
  • Due to the expansion of cities and the increasing number of large-scale and complex public spaces, there is an increase in public signage. Moreover, the information described on these signs tends to be diverse and complicated. Complex signs that contain multiple destinations or other information must be considered to determine not only the proper size, color, etc. but also the most effective arrangement of design elements. In the previous research, the cognitive utility of complex public signs was estimated using computer simulation software. In the current research, we focused on the objective estimation of the effectiveness of the results obtained in the previous research utilizing an eye mark recording system. Two cognitive engineering experiments clarified five points for improvement in the usability of complex signs, as follows: 1) Parallel construction of characters and pictograms is more efficient. 2) Grouping elements result in rapid recognition of information chunks. 3) Visual characters and pictograms are effective, along with proper density of information. 4) Specific arrangement of sign arrows is effective. 5) Figures on signs influence the sequence of information searches.

막여과 정수처리공정에서 전여과공정의 효용성 평가 (Utility Estimation of Pre-filtration on the Membrane Water Treatment Process)

  • 박민구;최상일
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.445-448
    • /
    • 2008
  • The application of the membrane filtration process has been increased for the drinking water treatment system because of excellent quality of treated water compared with the sand filtration process. The selection of suitable pre-treatment processes and optimum flux according to the characteristics of raw water are important factors for the design of membrane processes. In this study, the most efficient pre-treatment processes for drinking water was selected by investigating the effects of pre-treatment processes on the operational stability of the membrane filtration process. Both lab-scale and pilot-scale experiments were conducted. In the lab-scale test, the effect of pre-treatment processes on the stability of the membrane filtration process was investigated indirectly by comparing the performance of membrane flux for raw water, pre-treated water, and membrane permeated water. In the pilot-scale test, the usefulness of prefiltration processes was assessed by comparing the performance of single membrane process and hybrid coagulation-membrane process. The results indicated that the coagulation process contributed to the stabilization of trans-membrane pressure (TMP) by removing contaminants on membranes, though the pre-filtration process had little effect on the TMP.

Estimation of Leucine Aminopeptidase and 5-Nucleotidase Increases Alpha-Fetoprotein Sensitivity in Human Hepatocellular Carcinoma Cases

  • Abouzied, Mekky Mohammed;Eltahir, Heba M.;Fawzy, Michael Atef;Abdel-Hamid, Nabil Mohie;Gerges, Amany Saber;El-Ibiari, Hesham Mohmoud;Nazmy, Maiiada Hassan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권3호
    • /
    • pp.959-963
    • /
    • 2015
  • Purpose: To find parameters that can increase alpha-fetoprotein (AFP) sensitivity and so help in accurate diagnosis and rapid management of hepatocullular carcinoma (HCC), as AFP has limited utility of distinguishing HCC from benign hepatic disorders for its high false-positive and false negative rates. Materials and Methods: Serum levels of AFP, 5'-nucleotidase enzyme activity (5-NU) and leucine aminopeptidase enzyme (LAP) activity were measured in 40 individuals. Results: LAP and 5'NU were elevated in HCC at p<0.001. Pearson correlation coefficients showed that changes in AFP exhibited positive correlation with both 5'-NU and LAP at (p<0.001). The complementary use of LAP only with AFP resulted in an increase in sensitivity of AFP from 75% to 90% in detecting HCC. The complementary use of both LAP and 5-NU with AFP resulted in an increased sensitivity of AFP in detecting HCC from 75% to 95%. Conclusions: LAP and 5-FU can be determined in HCC patients in combination with AFP to improve its sensitivity and decrease false negative results.

직선 배열형 마이크로폰 어레이를 이용한 빔포밍 음향홀로그래픽법에 관한 연구 (A Study for Beamforming Acoustic Holographic Method Using Linear Arrayed Microphones)

  • 김천덕;심동연;장비;차경환;이채봉
    • 한국음향학회지
    • /
    • 제19권3호
    • /
    • pp.3-10
    • /
    • 2000
  • 본 논문에서는 등간격으로 직선배열된 마이크로폰 어레이군으로 각 측정지점마다 빔패턴을 형성하고 이를 기준신호로 이용하여 각 마이크로폰들간의 신호와 크로스스펙트럼 알고리즘에 의하여 음원의 절대위치를 추정할 수 있는 빔포밍 음향홀로그래픽 시스템을 제안한다. 실음장 측정을 통하여 기준 마이크로폰을 사용하는 음향홀로그래픽법과 본 연구에서 제안한 방법을 동일 알고리즘으로 비교·검토한 결과, 약 20% 이상의 분해능 향상을 가져왔으며 제작한 시스템의 음장측정에 대한 유용성을 확인하였다.

  • PDF

EDMS를 이용한 인천국제공항의 대기오염 배출량 산정과 주변지역에 미치는 영향 평가 (Assessment of Air Pollution and Estimation of Emission from Incheon International Airport by EDMS)

  • 이성용;장영기
    • 환경영향평가
    • /
    • 제11권2호
    • /
    • pp.67-77
    • /
    • 2002
  • Air traffic increased 12% annually in Korea since 1988 after the Olympics, this rate is two times than the rate of the world average. In order to accommodate fast growing aviation demand, Incheon International Airport is operated at Yongjong Island since March, 2001. The Incheon airport project will continue till 2020. After the final phase in 2020, Incheon International Airport will handle 100 million passengers, 530,000 flights and 7 million tons of cargo annually. In this study, air pollution from aircraft and other sources are calculated and assessed in Incheon International Airport area by EDMS(Emission and Dispersion Modeling System), which is a combined emission and dispersion model for airport. EDMS could also be considered power plant, incinerator and aircraft support equipment such as ground support equipment, aerospace ground equipment, auxiliary power units. And EDMS is recommended as preferred model for air quality assessment of the airport area by U.S. EP A. The result of this study shows that NOx emission from aircraft and support utility is estimated as 27,000 - 35,000 ton/yr and Namdong-Gu area in Incheon city is affected as 30-60 ppb by the NOx emission from these sources in 2020, the final phase of Incheon international airport construction.