• 제목/요약/키워드: utility detection

검색결과 225건 처리시간 0.028초

다중 채널 EPD제어기의 개발 (Development of multiple channel EPD controller)

  • 최순혁;차상엽;이종민;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1500-1503
    • /
    • 1997
  • In this paper a multiple channel EPD controller is developed which enables us to detect endpoints simultaneously in the plasma etching process operated in multiple etching chambers and its performance characteristic are investigated. for the accurate detectiion of endpoint the developed EDP controller was able to implement endpoint detectiions by integrating the existing EPD controllers with the techiques of artificial intellignet, to enhance its performance. The performance of the developed EPD controller was carried out by repeated experiments of endpoint detection in the acrual production line of semiconductor manufacturing. It's utility for endpoint detectiion was accurately evaluated in various etching process. The control capability of multiple etching chambers enhances its application compared with the existing one, and also increases the user utility os that the efficiency of operation was improved.

  • PDF

분산형전원이 도입된 배전계통에 대한 ISLANDING DETECTION METHOD (Islanding Detection Method of Embedded Generator connected to Power Distribution System)

  • 황진수;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.522-524
    • /
    • 2000
  • The installation of small sized Embedded Generator(EG) in parallel with the utility supply was required several technical complications for protection of the system. One of the most important protection is to provide protection against islanding and out of synchronism reclosing with the utility source. This paper explains several current methods of detecting 'Loss Of Mains'(LOM). But they have not proved completely dependable, in particular when the islanded load's capacity matches that of the EG. A new loss of mains protection algorithm is presented in this paper which based on measurement of the reactive power and node voltage for detecting the islanding condition even though the EG operate in the capacity.

  • PDF

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF

무효전력 제어를 통한 새로운 독립운전 검출법 (A Novel Method for Anti-Islanding Using Reactive Power Control)

  • 정진범;최봉주;안강순;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.208-216
    • /
    • 2005
  • Recently, the study of islanding phenomenon, maintains its operation even when the utility grid is removed has lead to the trend of utility interactive inverters in photovoltaic generation systems. In this paper, a novel Anti-islanding method is presented. the proposed method can keep the real average power component constant by MPPT control and cause the load current frequency with only change of reactive power component under the islanding condition. its periodical change of Reactive power component can decrease the NDZ(Non-Detective zone) so that the detection of various loads will be possible. the insufficient effect if additional reactive power component to the grid is proved theoretically and the islanding detection is also confirmed from a experimental result with a inverter for 3kW photovoltaic generation system applied the proposed Anti-islanding method.

전자유도 탐사를 이용한 지하매설물 탐지 정확도 분석 (A Study on the Detecting Accuracy of EM Induction Survey Data of Buried Utility)

  • 권형석;최준호;황대진;김문재;윤정섭
    • 한국재난관리표준학회지
    • /
    • 제1권4호
    • /
    • pp.73-81
    • /
    • 2008
  • 전자유도 탐사는 매설관로에서 발생되는 자기장을 측정하는 탐사방법으로 하나의 관로만 매설되어 있는 경우에는 20 cm 이내의 높은 정확도를 보이지만, 탐지대상 관로 인근에 다른 관로가 매설되어 있으면 자기장의 교란으로 정확도가 감소한다. 본 연구에서는 지하매설물 탐지 정확도 향상을 위하여 대칭성을 이용하여 매설관로의 수평위치를 검증하는 방법과 에너지 크기 비교법과 삼각법을 이용하여 매설심도를 검증하는 방법에 대해 고찰하였다. 다음으로 현재 판매되는 전자유도 탐사장비가 별도의 저장장치를 가지고 있지 않아 측정자료의 분석이 불가능한 문제를 개선하기 위하여, Bluetooth 무선통신장치를 이용하여 측정자료를 저장하는 방법을 개발하였다. 마지막으로 두 개의 인접관로를 하나로 오인하는 문제점을 개선하기 위하여 현장모형실험을 통해 인접관로의 거리에 따른 분해능을 고찰하였다.

  • PDF

PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법 (A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System)

  • 강성욱;김경화
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성 (A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation)

  • 방지윤;김학만;이복구;심재선;신명재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

Utility of Digital Rectal Examination, Serum Prostate Specific Antigen, and Transrectal Ultrasound in the Detection of Prostate Cancer: A Developing Country Perspective

  • Kash, Deep Par;Lal, Murli;Hashmi, Altaf Hussain;Mubarak, Muhammed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권7호
    • /
    • pp.3087-3091
    • /
    • 2014
  • Purpose: To determine the utility of digital rectal examination (DRE), serum total prostate specific antigen (tPSA) estimation, and transrectal ultrasound (TRUS) for the detection of prostate cancer (PCa) in men with lower urinary tract symptoms (LUTS). Materials and Methods: All patients with abnormal DRE, TRUS, or serum tPSA >4ng/ml, in any combination, underwent TRUS-guided needle biopsy. Eight cores of prostatic tissue were obtained from different areas of the peripheral prostate and examined histopathologically for the nature of the pathology. Results: PCa was detected in 151 (50.3%) patients, remaining 149 (49.7%) showed benign changes with or without active prostatitis. PCa was detected in 13 (56.5%), 9 (19.1%), 26 (28.3%), and 103 (74.6%) of patients with tPSA <4 ng/ml, 4-10 ng/ml, 10-20 ng/ml and >20 ng/ml respectively. Only 13 patients with PCa had abnormal DRE and TRUS with serum PSA <4 ng/ml. The detection rate was highest in patients with tPSA >20 ng/ml. The association between tPSA level and cancer detection was statistically significant (p<0.01). Among 209 patients with abnormal DRE and raised serum PSA, PCa was detected in 128 (61.2%). Conclusions: The incidence of PCa increases with increasing serum level of tPSA. The overall screening and detection rate can be further improved by using DRE, TRUS and TRUS-guided prostate needle biopsies.

딥러닝 기반 지하공동구 제어반 문열림 인식 (Deep Learning-based Object Detection of Panels Door Open in Underground Utility Tunnel)

  • 김경환;김지은;정우석
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.665-672
    • /
    • 2023
  • 연구목적: 지하공동구는 도시 지하에 전기, 수도, 가스 등의 인프라를 공동 수용하는 시설로 공기 흐름이 부족하여 계절에 상관없이 결로가 자주 발생한다. 결로는 전기 설비의 누전 화재를 일으키는 원인이 되므로 지하공동구 내의 조명 등 각종 시설물 관리를 위해 필요한 제어반은 결로에 노출되지 않도록 문이 닫힌 상태로 관리되어야 한다. 본 논문에서는 딥러닝 객체인식 기술을 활용하여 수km 거리에 반복 배치된 공동구 제어반의 문 열림 여부를 이동 카메라 조건과 조명이 꺼진 조건에서도 인식하고자 한다. 연구방법: 지하공동구를 순찰하는 로봇이 촬영한 영상데이터를 이용하여 딥러닝 객체인식 모델인 YOLO를 모자이크 이미지 증강기법으로 학습시켜 제어반 문 열림과 문 닫힘을 인식한다. 연구결과: 모자이크 이미지 증강기법으로 학습시킨 모델과 사용하지 않은 모델의 성능을 비교한 결과, 모자이크 학습 모델이 더 우수한 성능(모든 클래스에 대한 mAP가 0.994 이상임)을 보이는 것을 확인하였다. 결론: 지하공동구의 조명이 꺼진 상태에서도, 공동구 내부 시설물이 복잡한 환경에서도 제어반의 문열림 여부를 우수한 성능으로 인식하여 지하공동구 재난안전관리에 도움이 될 것으로 기대된다.

보 구조물의 주파수응답을 이용한 화음탐색법 기반 손상검색 (Damage Detection in Beam Structures using Harmony Search Method and Frequency Response)

  • 이소영;박재형;이진학;류연선;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.139-144
    • /
    • 2008
  • In this study, damage detection method using harmony search method and frequency response is proposed. In order to verify this method, the following approaches are implemented. Firstly, damage detection method using harmony search is developed. To detect damage, objective function that minimize difference with natural frequency and modal strain energy from undamaged and damaged model is used. Secondly, finite element model for beam structure is created. And damage scenario is determined. Lastly, damage detection is performed by proposed method and utility of proposed method is verified.

  • PDF