• Title/Summary/Keyword: utility damage

Search Result 125, Processing Time 0.026 seconds

A Novel Active Anti-islanding Method using Effective Power Variation (유효전력변동방식을 이용한 새로운 단독운전 검출기법 연구)

  • Yu Byung-Gyu;Jung Young-Seok;Matsui Mikihiko;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.213-215
    • /
    • 2006
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent the phenomenon, various anti-islanding methods have been studied. This paper proposes the variation method of inverter output current magnitude to prevent the islanding phenomenon as a novel method, which causes the large frequency variation of inverter output voltage after islanding. Unlike most active anti-islanding method deteriorating power quality, this novel method will have high performance of islanding detection and good power quality. For the verification of the proposed method, the simulated result and analyses are presented.

  • PDF

Islanding detection of grid-connected photovoltaic inverters using Automatic phase-shift method (계통연계형 PV 인버터의 자동 위상 이동법에 의한 고립운전 검출)

  • Yun, Jung-Hyeok;Kim, Heung-Geun;Choi, Jong-Woo;Chun, Tae-Won;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.591-594
    • /
    • 2005
  • Islanding of PV systems occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding Is one of the serious problems in an electric power system connected with dispersed power sources. Also, this scan present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

Modeling and Evaluation of Slip-Mode Frequency Shift Method for Anti-islanding Method (슬립모드 방식을 이용한 단독운전 검출기법의 모델링과 평가)

  • Yu, Byung-Gyu;Jung, Young-Seok;So, Jung-Hun;Yu, Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.520-522
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift (SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection zone (NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through the modeling and verified visually by simulation and experiment.

  • PDF

A Study on the Out-of-Step Detection Algorithm using Voltage Frequency Variation (전압의 주파수 변화를 이용한 동기탈조 검출 알고리즘에 관한 연구)

  • So, K.H.;Heo, J.Y.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.335-337
    • /
    • 2003
  • The protection against transient instability and consequent out-of-step condition is a major concern for the utility. The unstable system may cause serious damage to system elements such as generators and transmission lines. Therefore, out-of-step detection is essential to operate a system safely. This paper presents the Out-of-Step detection algorithm using voltage frequency variation. The digital filters based on Discrete Fourier Transforms (DFT) to calculate the frequency of a sinusoid voltage are used, and the generator angle is estimated using the variation of the calculated voltage frequency. The proposed out-of-step algorithm is based on the assessment of a transient stability using equal area criterion. The proposed out-of-step algorithm is verified and tested by using EMTP MODELS.

  • PDF

An Adaptive Relaying Algorithm on Utilities' Electrical Feeders for Improving the Reliable Operation of Wind Farm Interconnected with Utility Grid (계통 연계 풍력발전단지의 운전효율 향상을 위한 배전 계통의 적응형 보호 계전 알고리즘)

  • Jang, Sung-Il;Kim, Ji-Won;Choi, Don-Man;Kim, Kwang-Ho;Kim, Hyung-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.338-341
    • /
    • 2003
  • This paper proposes the adaptive relaying algorithm of protective devices applied in the neighboring distribution feeders for reliable and efficient operations of a wind farm interconnected with distribution networks by dedicated lines. Generally, it would be highly possible that the wind turbine generators are influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the dedicated power line. The delayed operation time of protective devices for satisfying the coordination might overly expose the interconnected wind turbine generators to the fault and cause damage to them. In order to reduce the damages on the interconnected wind farm about the faults happening in distribution networks, this paper describes the proper delayed operation time of protective relay.

  • PDF

Pedestrian Protection System Design for SUV Using the Design of Experiments (실험계획법을 이용한 SUV의 보행자 보호 시스템 설계)

  • Lee, Youngmyung;Choe, Wonseok;Park, Gyung-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.24-32
    • /
    • 2016
  • The mortality rate of car-pedestrian accidents is quite high, compared to the frequency of accidents. Researches on pedestrian protection are being actively performed worldwide. The A-pillar and lower part of the wind shield cause the most serious damage to the pedestrians. Typical devises to protect the pedestrians are the hood lift system and pedestrian airbag. The design of such devices for an sport utility vehicle is performed based on a design process using design of experiments (DOE). The design results are obtained by an orthogonal array (OA), analysis of mean (ANOM) and analysis of variance (ANOVA). A metamodel is also used in the design process.

Propagation of Lightning Surges toward primary Side of Distribution Transformer (배전용 변압기 고압측으로의 뇌서지 전파)

  • 이복희;이수봉;김병근;이승칠;이동문;정동철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.269-272
    • /
    • 2003
  • The importance of the improving quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and system. The transient overvoltage on low-voltage AC power distribution system are induced by direct or indirect lightning return strokes, and those can cause damage and/or malfunction of the utility system for borne automation, office automation and factory automation as well as medical equipments. The behavior of lightning surge transferred to the primary side from the primary side in distribution transformers were experimentally investigated the protection effect of low voltage SPD installed at the secondary side of distribution transformers was analyzed.

  • PDF

Implementation of Out-of-Step Detection Algorithm based on Multi-Agent System using EMTP-MODELS (EMTP-MODELS를 이용한 Multi-Agent System 기반의 동기탈조 검출 알고리즘 구현)

  • Lee, Byung-Hyun;Yeo, Sang-Min;Lee, You-Jin;Sung, No-Kyu;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.537-542
    • /
    • 2008
  • The protection against transient instability and consequent out-of-step condition is a major concern for the utility industry. Unstable system may cause serious damage to system elements such as generators and transmission lines. Therefore, out-of-step detection is essential to operate a system safely. Also, a multi-agent system is one that consists of a number of agents, which interact with one another. Multi-agent systems(MAS) can offer the flexibility and the adaptability to the previous algorithm. In this paper, the detection algorithm of out-of-step is designed by multi-agent system and implemented by EMTP-MODELS. To verify performance of the proposed algorithm based on multi-agent system, simulations by EMTP have been carried out.

A Study on the Grounding Impedance Effects and Its Characteristics (접지 임피던스의 영향분석에 관한 연구)

  • Chang, Myong-Soo;Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1948-1949
    • /
    • 2007
  • This paper presents the characteristics and effects of grounding resistor and impedance. In grounding system, Grounding resistor is governed neutral currents and voltage. It seems that, grounding resistor has 0 value, then circuit has no faults. While if grounding resistor has large value, then neutral current has large value of fault current and it is made a damage to the utility. In order to analyze the grounding impedance characteristic, EMTP simulation has been used. The grounding impedance characteristic has been analyzed and tested for various grounding arrangements and electrode circuit shapes.

  • PDF

Analysis and Modeling of Slip Mode Frequency Shift Method for Anti-islanding (슬립모드 주파수변이 방식의 단독운전 검출법의 분석과 모델링)

  • Yu, Byung-Gyu;Jung, Young-Seok;So, Jung-Hun;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1699-1701
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and rower supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift(SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection tone(NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through modeling and verified visually by simulation and experiment.

  • PDF