• Title/Summary/Keyword: urine analysis system

Search Result 84, Processing Time 0.024 seconds

Immunohistochemical Detection of p53 Gene Mutation in Urine Samples in the Patients with Bladder Cancer (방광암 환자의 요세포 검사에서 p53 단백 발현의 의의)

  • Lee, Sang-Sook;Bae, Ji-Yeon;Kang, Yu-Na;Cho, Young-Rok;Park, Nam-Jo;Kim, Seun-Young;Kim, Jung-Hi
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.144-150
    • /
    • 1996
  • Although bladder cancers are very common, little is known about their molecular pathogenesis. It is known that p53 alteration is found in about 60% of muscle-invasive bladder cancer, necessiating aggressive therapy and poor outcome. We examined the nuclear expression of p53 protein, using D07 monoclonal antibody in the urine samples from 31 patients with transitional cell carcinoma of the bladder to investigate the correlation of p53 overexpression with histologic grades and depth of invasion. The positive rate of p53 protein was 27% in superficial bladder tumor, but increased up to 71% in the invasive bladder carcinomas. The overexpression of p53 protein increased according to Mostofi grading system from 18% in grade I, 45% in grade II, and up to 100% in grade III. The p53 expression tended to be higher in the invasive and high grade bladder cancers than in the superficial and low grade ones(p<0.05). These results suggest that immunohistochemical analysis of the urine specimen in the bladder cancer patients could be a useful method of screening for the presence of p53 mutant protein. The mutant p53 protein expression may be an indicator of bladder cancer with more proliferative potential and/or aggressive biologic behavior.

  • PDF

Simultaneous determination of amphetamine-like drugs in human urine by SPE and GC/MS (고체상추출과 GC/MS를 이용한 소변 중 암페타민계 마약성분 동시분석법)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • Although liquid-liquid extraction (LLE) method has been used routinely for the analysis of amphetamine-like drugs (amphetamine; AP, methamphetamine; MA, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA), a solid-phase extraction (SPE) method, which can be automated, was applied for the simultaneous determination by GC/MS in human urine. Urine samples (3 mL) and 0.1 M phosphate buffer (1 mL, pH 7.0) were extracted by an automated SPE system. The eluent was evaporated, derivatized with trifluoroacetic anhydride (TFAA), and analyzed by GC/MS. The calibration curves was linear with correlation coefficient ($r^2$) above 0.994 in the ranges of 34.0 (AP), 28.0 (MDA)~1000.0 ng/mL for AP, MDA, and 50.0~2000.0 ng/mL for MA, MDMA, and MDEA. The limits of detection ranged from 4.0 to 10.0 ng/mL, and the limits of quantitation ranged from 12.0 to 34.0 ng/mL. The relative recoveries were 93.5~107.7 %. The precisions and accuracies were 1.9~14.8 % and -8.7~14.8 %, respectively. The present method was successfully applied to identify the MA or Ecstasy (MDMA) abusers in exact as well as rapid.

Implementation of Fuzzy Classifier and Automatic Turning for Urine Analyzer System using the Strip (스트립을 이용한 뇨분석 시스템의 퍼지 분류기 및 자동 튜닝 구현)

  • Kim, K.W.;Lee, S.J.;Kim, K.N.;Choi, B.C.;Ye, S.Y.;Jun, K.R.;Cho, J.W.;Kim, J.H.;Lee, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.141-142
    • /
    • 1998
  • The urine analysis system implemented to measuring the primary color reaction of urinalysis strip. Fuzzy classifier based on fuzzy theory implemented so as to classify of 9 items in the urinalysis strip and proposed the automatic turning algorithm of mambership function in the fuzzy classifier to progress the reproduction of classify. To evaluation of clinical capability, the fuzzy classifier and automatic turning algorithm apples to standard strip and standard reagent.

  • PDF

Analysis Method of N-Nitrosamines in Human Urine by LC-MS/MS System (LC-MS/MS 시스템을 이용한 소변 중 N-니트로사민류 분석법 확립)

  • Park, Na-Youn;Jung, Woong;Kho, Younglim
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • N-nitrosamines are the nitroso compounds which are produced by nitrosation reactions of the secondary amine and nitrite under acidic conditions. Approximately 300 species of N-nitrosamine have been tested for carcinogenicity in laboratory experiments, with 90% of them demonstrated carcinogenic effects different animal species, including higher primates. In 1978, IARC classified NDMA and NDEA as Group 2A, and NDPA, NDBA, NPIP, NPYR and NMOR as Group 2B. In this study, we established pretreatment and analytical method for N-nitrosamines (NDMA, NDEA, NMEA, NDPA, NDBA, NPIP, NPYR and NMOR) in human urine for biological monitoring of N-nitrosamines. The analytes were extracted using solid phase extraction (SPE), then quantitative analysis was performed by LC-(APCI)-MS/MS. The accuracies of the established method were between 85.8~108.7% and precisions were lower than 20%. The limit of detection (LOD) were between 0.0002 (NDBA) and 0.0793 (NDMA) ng/ml. The linearity obtained was satisfying for the 8 N-nitrosamines, with a coefficient of determination ($r^2$) higher than 0.999. The mean concentrations of N-nitrosamines in the urine were 2.645 mg/g creatinine for NDMA, 0.067 mg/g creatinine for NDEA, 0.009 mg/g creatinine for NMEA, 0.011 mg/g creatinine for NDBA, 0.271 mg/g creatinine for NPIP and 0.413 mg/g creatinine for NPYR. NDPA and NMOR were not detected. It can be used as a instrumental methodology for evaluation and risk assessment of human exposure to N-nitrosamines for the further research.

Usefulness Assessment of Noninvasive Bladder Pressure Measurement for BPH Diagnosis (전립선 비대증 진단에서의 비침습적 방광내압계측 유용성 평가)

  • Jeong, Do-Un;Chung, Wan-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.865-866
    • /
    • 2006
  • The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfort methods. There for in this study hardware device and computer software have been developed that enables the analysis of the urine flow rate and vesical pressure signal measured during voiding. These signals were recorded simultaneously and transmitted to the PC. For the measurement system evaluation, the model system for the lower urinary system of men was designed. From the evaluation of the model system, vesical pressure was correlated with the occlusion degree. In a pilot study on 5 male subjects, means of standard deviation was 1.06, average error rate was 2.09 and coefficient variation was 2.09.

  • PDF

Bioluminescence Single-Site Immunometric Assay for Methamphetamine Using the Photoprotein Aequorin as a Label

  • Kim, Hyun-Sook;Paeng, Insook-Rhee
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.3
    • /
    • pp.407-412
    • /
    • 2006
  • Bioluminescence single-site immunometric assay for methamphetamine (MA) using the native aequorin, a photoprotein, as a signal generator was developed for the first time. MA is a potent sympathomimetic amine with stimulant effects on the central nervous system. MA abuse induces hallucinations and, thus, may cause a serious social problem. The single-site immunometric MA assay was optimized and its dose-response behavior was examined. The dose-response curve shows that the detection limit is 1.1 ${\times}$ $10^{-10}$ M and a dynamic range is four orders of magnitude with 15 $\mu$g/mL BSA-MA conjugate and 1.0 ${\times}$ $10^{-8}$ M anti-MA antibody-biotin conjugate. In order to evaluate this assay, the structurally similar compounds, amphetamine, ephedrine, norephedrine, benzphetamine and N-4-(aminobutyl)methamphetamine were examined for their crossreactivity. None of these five compounds showed any cross-reactivity. Additionally, an artificial urine solution spiked with MA was analyzed by the MA assay, and the result of the analysis demonstrated the usefulness of the present assay for the determination of MA in urine.

Risk Factors for Nosocomial Urinary Tract Infection in the Intensive Care Unit with a Positive Urine Culture and Foley Catheterization (소변 미생물 균주 양성인 중환자실 유치도뇨관 환자의 병원성 요로감염 발생과 관련요인)

  • Yu, Seong-Mi;Park, Kyung-Yeon
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.7
    • /
    • pp.1149-1158
    • /
    • 2007
  • Purpose: The purpose of this study was to identify the risk factors for a nosocomial urinary tract infection in intensive care units with a foley catheterization which showed a positive urine culture. Method: Three-hundred eighty-seven patients were included in the study. A retrospective review of the electrical medical record system's databases and medical record sheets in hospitalized patients from January 2003 to December 2003 was used. The collected data was analyzed by descriptive statistics, t-test, chi-square test and logistic regression analysis. Result: The frequency of the participants' nosocomial urinary tract infection was 72.9%. Significant risk factors for a nosocomial urinary tract infection were 'age', 'place of catheter insertion', 'frequency of catheter change', and 'duration of catheterization'. These variables explained 18.4% of variance in the experience of nosocomial urinary tract infection in intensive care units with foley catheterization. Conclusion: Medical personnel can decrease the incidence of a nosocomial urinary tract infection by recognizing and paying attention to the duration of catheterization, frequency of catheter change, and place of catheter insertion. As a result, specific and scrupulous strategies should be developed to reflect these factors for decreasing nosocomial urinary tract infections.

Study on the Electric Potentials at Biophysical Meridian System (경락 전위를 이용한 경락의 생체물리학적 연구)

  • Choi Hwan-Soo;Nam Bong-Hyun
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.1-12
    • /
    • 2002
  • Objectives : Assuming That the Characteristic of Meridian System Has Been Similar to This of Electric Potentials in Human Body and That Measurements of Electric Potential at Well and Sea Points in Branches of the Twelve Meridians Will Be Representative of Measurements of the Twelve Meridians, to Measure the Electric Potentials in Healthy Volunteers(HG), Patients Diagnosed As a Cerebral Infarction(CG), a Arrhythmia(AG), a Other Intervertebral Disc Disorder(IG), and a Joint Disorder(JG), and Then to Find Out the Characteristic of Biophysical Meridian System, Finally to Compare with the Results of the Electric Potential in Those Groups. Methods : We Selected Who HG Were Diagnosed by a Blood Test, Urine Examination and Differentiation of Syndromes by Five Viscera among Volunteers, CG by CT and Wind-Syndrome Caused by Hyperactivity of the Liver-Yang, AG by EKG, CT, and Deficiency or the Heart Blood, IG by X-ray or CT and Pain in Waist, and JG by X-ray and Knee Pain. Their Electric Potential of Well and Sea Points in the Meridians Were Measured by hysiograph. Results and Conclusions : Measurements Were Analyzed by Factor Analysis, Analysis of Variance, and Logistic Regression Model, We Obtained That Most of the Results, In Conclusion, Hold Good for the Classical Meridian Doctrine.

  • PDF

Generation and Characteristics Analysis of Swine Manure for Introducing Biogas System (논문 - 바이오가스화 도입을 위한 양돈농가 가축분뇨 발생 및 특성분석)

  • Choi, Eun-Hee;Yoon, Young-Man;Kim, Chang-Hyun
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.25-32
    • /
    • 2011
  • The 21 livestock farms considering future installation of biogas systems were studied. These farms were examined how to raise the livestock, to treat manure, to operate facility with respect to manure characteristics. The 15 farms out of 21 farms have applied to the marine dumping and consignment treatment for treating manure and even farms which have equipped liquid fertilizing system have less capacity facility than legal standards. Characteristics of manure were affected by the scale of swine barn, clean water usage, frequency of cleaning, cleaning method, feces-urine separating method, etc. Retention time in storage (over 20 days) has resulted in lower concentration of organic matter which could reduce biogas production. This indicates that systematic barn management system is required. Inhibition tests showed that disinfectant and citric acid did not affected digestion rates at 10 times higher concentration than recommendation. However hypochlorous acid is likely to affect the anaerobic microbial activity.

  • PDF

A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection

  • Alam, Seikh Mafiz;Jeon, Chi-Wan;Karim, Mohammad Mainul;Lee, Sang-Hak;Wabaidur, Saikh Mohammad;Suh, Yeoun-Suk;Chung, Hye-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.102-106
    • /
    • 2009
  • A rapid and sensitive chemiluminescence (CL) method using flow-injection (FI) has been developed for the determination of mandelic acid which is based on the enhancement of mandelic acid to the CL intensity of ${Ru(bipy)_{3}}^{2+}$-Ce(IV) system. The enhancement effect was dependent on the concentration of mandelic acid, based on which, CL system was established for the determination of mandelic acid. The concentrations of ${Ru(bipy)_{3}}^{2+}$+, Ce(IV), and $H_2SO_4$ were optimized. Under the optimum experimental conditions, the linear range and detection limit are 1.46-342.0 ${\mu}g/ml$ and 0.072 ${\mu}g/ml$, respectively. The correlation coefficient (R) was 0.99732. The utility of this method was demonstrated by determining mandelic acid in capsules and human urine sample.