• Title/Summary/Keyword: upper structures

Search Result 906, Processing Time 0.023 seconds

Experimental Study on the Flexural Capacity of the U-Flanged Truss Hybrid Beam (U-플랜지 트러스 복합보의 휨 내력에 대한 실험 연구)

  • Oh, Myoung Ho;Kim, Young Ho;Kim, Myeong Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.123-130
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars welded on the upper and lower sides. The hybrid beam with U-flanged steel truss is made in the construction site through pouring the concrete, and designated as U-flanged truss hybrid beam. In this study the structural experiments on the 4 hybrid beams with the proposed basic shapes were performed, and the flexural capacities from the tests were compared with those from the theoretical approach. The failure modes of each specimen were quite similar. The peak load was reached with the ductile behavior after yielding, and the failure occurred through the concrete crushing. The considerable increasement of deformation was observed up to the concrete crushing. The composite action of concrete and steel member was considered to be reliable from the behavior of specimens. The flexural strength of hybrid beam has been evaluated exactly using the calculation method applied in the boubly reinforced concrete beam. The placement of additional rebars in the bottom instead of upper side is proposed for the efficient design of U-flanged truss hybrid beam.

Study on the Equation of Natural Period of Middle and Low Rise Building of Upper-Walled Lower Frame Type (중저층 상부벽식 하부골조 구조의 고유주기 산정식에 관한 연구)

  • Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.60-67
    • /
    • 2021
  • According to the 「Guidelines of Structural Design for Piloti Building」 of the Ministry of Land, Infrastructure and Transport (2018), the natural period of middle and low rise building of upper-walled lower frame type, such as the domestic multiplex house in piloti style, is suggested for safety to apply the existing code formula of the wall structure. However, the current code formula of the wall structure was provided based on actual measurement of high-rise wall-type structures that mainly exhibit bending behavior. So it is considered that it is not suitable for a piloti-type house with four stories or less, where the wall behaves in shear. See also Park et al. (2000) confirmed that the effect of the lower frame part is greater than that of the upper wall part in the natural period of complex structures with 10 or more floors through analytical studies. Therefore, in this study, in order to examine the effect of the lower frame on the natural period of the middle and low-rise piloti structure, the estimation of natural period by the finite element analysis, approximation formula and ccurrent code formula was performed for the target structures with the shear and flexural stiffness of the upper wall and the shear stiffness of the lower frame as variables. As result, it was found that the change in the shear stiffness of the lower frame had a greater effect on the natural period of the whole building than the change in the bending or shear stiffness of the upper wall.

A Basic Study on the Influence of an Understructure on the Seismic Response of a Spatial Structure (공간구조의 지진응답에 대한 연구 하부구조의 영향에 관한 기초적 연구)

  • Jung, Chan-Woo;Jung, Hwan-Mok
    • Proceeding of KASS Symposium
    • /
    • 2005.05a
    • /
    • pp.215-226
    • /
    • 2005
  • To study the influence of an lower part on the seismic response of a spatial structure as the upper part of a structure, as a first step, authors subsititude the upper part and the lower part of a structure to single degree of freedom systems indivisually, and set up structural models connected by them. It is clarified that the mass ratio and the period ratio of an upper part to a lower part are important parameteres to find the amplification or reduction of the sesimic response of an upper part by considering of a lower part.

  • PDF

The Investigation of Structural Behavior with Variations in the Lower Stories of Complex Buildings using Push-over Analysis (Push-over 해석을 사용한 복합구조물의 하부골조 층수변화에 따른 거동분석)

  • 강병두;전대한;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.398-405
    • /
    • 2001
  • Upper wall-lower frame(complex building) can be divided into three partition, namely, upper wall, lower frame, and transfer system which link two partitions. The purpose of this study is to investigate the elasto-plastic response characteristics of structures with variation in the stories of lower frame of complex buildings. The conclusions of this study was following; 1) In the push-over analysis for vertically irregular building, the distribution of lateral forces is judged which consider the effects of higher mode. 2) In proportion as the stories of lower frame increase inter-story displacement of lower frame increased, but that of upper wall decreased. 3) The appearance of yielding hinge with variations in the lower stories of complex buildings differed in lower frame of each model, but was almost the same in upper wall.

  • PDF

The Response Characteristics of Nonlinear Pushover Analysis of Upper Wall-Lower Frame System with X and Y-Directions (X, Y 방향에 따른 상부벽식-하부골조의 비선형 정적응답특성)

  • 강병두;전대한;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.209-216
    • /
    • 2003
  • The purpose of this study is to investigate the response characteristics of pushover analysis of upper wall-lower frame system with X and Y-directions' lateral load Pushover analysis estimates initial elastic stiffness, post-yielding stiffness, and plastic hinges on each story of structures through three-dimensional nonlinear analysis program. The conclusions of this study are as follows; (1) As a result of pushover analysis, the magnitude of nonlinear response and distribution of yield hinge in lower structure are similar with both X and Y directions, but not in upper structure because of different relative stiffness. (2) The maximum drift ratio of roof is larger for X-direction than for Y-direction with respect to magnitude of shear wall areas in upper structure.

  • PDF

Vascularized Bone Graft Reconstruction for Upper Extremity Defects: A Review

  • Ava G. Chappell;Matthew D. Ramsey;Parinaz J. Dabestani;Jason H. Ko
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.82-95
    • /
    • 2023
  • Upper extremity reconstruction may pose clinical challenges for surgeons due to the often-critical, complex functional demands of the damaged and/or missing structures. The advent of vascularized bone grafts (VBGs) has aided in reconstruction of upper extremity (UE) defects due to their superior regenerative properties compared with nonvascularized bone grafts, ability to reconstruct large bony defects, and multiple donor site options. VBGs may be pedicled or free transfers and have the potential for composite tissue transfers when bone and soft tissue are needed. This article provides a comprehensive up-to-date review of VBGs, the commonly reported donor sites, and their indications for the treatment of specific UE defects.

Electromigration-induced void evolution in upper and lower layer dual-inlaid Copper interconnect structures

  • Pete, D.J.;Mhaisalkar, S.G.;Helonde, J.B.;Vairagar, A.V.
    • Advances in materials Research
    • /
    • v.1 no.2
    • /
    • pp.109-113
    • /
    • 2012
  • Electromigration-induced void evolutions in typical upper and lower layer dual-inlaid Copper (Cu) interconnect structures were simulated by applying a phenomenological model resorting to Monte Carlo based simulations, which considers redistribution of heterogeneously nucleated voids and/or pre-existing vacancy clusters at the Copper/dielectric cap interface during electromigration. The results indicate that this model can qualitatively explain the electromigration-induced void evolutions observations in many studies reported by several researchers heretofore. These findings warrant need to re-investigate technologically important electromigration mechanisms by developing rigorous models based on similar concepts.

Efficient 3D Analysis of Building Structures with A Rigid Floor System (주상복합구조물의 효율적인 3차원 해석)

  • 황현식;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.239-246
    • /
    • 1996
  • Very stiff floor system in a residential-commercial building causes some problems in the numerical analysis procedure due to significant difference in stiffness with adjacent structural elements. Static analysis of structure with a stiff transfer-floor can be peformed approximately in two steps for upper and lower pons for the structure. However, it is impossible to perform dynamic analysis in two steps with separate models. An efficient method for dynamic analysis of a structure with a rigid floor system is proposed in this study. The matrix condensation technique is employed to reduce the degree of freedom for upper and lower parts of the structure and a beam elements with rigid bodies of both ends are introduce to model the rigid floor system. Efficiency end accuracy of the proposed method ore verified through analysis of several example structures.

  • PDF

Flexible multimode pressure sensor based on liquid metal

  • Zhou, Xiaoping;Yu, Zihao
    • Smart Structures and Systems
    • /
    • v.28 no.6
    • /
    • pp.839-853
    • /
    • 2021
  • In this paper, a novel multimode liquid metal-based pressure sensor is developed. The main body of the sensor is composed of polydimethylsiloxane (PDMS) elastomer. The structure of the sensor looks like a sandwich, in which the upper structure contains a cylindrical cavity, and the bottom structure contains a spiral microchannel, and the middle partition layer separates the upper and the bottom structures. Then, the liquid metal is injected into the top cavity and the bottom microchannel. Based on linear elastic fracture mechanics, the deformation of the microchannel cross-section is theoretically analyzed. The changes of resistance, capacitance, and inductance of the microchannel under pressure are deduced, and the corresponding theoretical models are established. The theoretical values of the pressure sensor are in good agreement with experimental data, implying that the developed theoretical model can explain the performance of the sensor well.

An Experimental Study on the Vertical Vibration Transfer according to Rahmen Building Structures due to Train Loads (라멘조 건축구조물의 수직진동 전달특성에 관한 실험연구)

  • 전호민
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.469-475
    • /
    • 2004
  • The vibration on building structures due to exciting vibration forces has been studied only for the vibration level on existing buildings. Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the dynamic characteristics of vertical vibration transfer from lower stories to upper ones on the Rahmen building structures due to traffic loads. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on one building structures. The results of this study suggest that the characteristics of vertical vibration transfer are different in terms of the type of trains.

  • PDF