Experimental Study on the Flexural Capacity of the U-Flanged Truss Hybrid Beam  

Oh, Myoung Ho (Dept. of Architectural Engineering, Mokpo National Univ.)
Kim, Young Ho (NTAGE)
Kim, Myeong Han (Dept. of Architectural Engineering, Mokpo National Univ.)
Publication Information
Journal of Korean Association for Spatial Structures / v.18, no.4, 2018 , pp. 123-130 More about this Journal
Abstract
U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars welded on the upper and lower sides. The hybrid beam with U-flanged steel truss is made in the construction site through pouring the concrete, and designated as U-flanged truss hybrid beam. In this study the structural experiments on the 4 hybrid beams with the proposed basic shapes were performed, and the flexural capacities from the tests were compared with those from the theoretical approach. The failure modes of each specimen were quite similar. The peak load was reached with the ductile behavior after yielding, and the failure occurred through the concrete crushing. The considerable increasement of deformation was observed up to the concrete crushing. The composite action of concrete and steel member was considered to be reliable from the behavior of specimens. The flexural strength of hybrid beam has been evaluated exactly using the calculation method applied in the boubly reinforced concrete beam. The placement of additional rebars in the bottom instead of upper side is proposed for the efficient design of U-flanged truss hybrid beam.
Keywords
U-flanged truss; Hybrid beam; Flexural capacity; Composite action;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Chae, H. S., Ryoo, J., Chung, K. S., Moon, Y. M., & Cho, S. M., "Experimental Study on Structural Performance of End-reinforced Steel-beam system(Eco-girder)", Journal of Korean Society of Steel Construction, Vol.22, No.6, pp.533-541, 2010
2 Heo, B. W., Bae, K. W., & Moon, T. S., "Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate", Journal of Korean Society of Steel Construction, Vol.16, No.2, pp.235-245, 2004
3 Kim, D. B., Kim, Y. H., Oh, M. H., & Kim, M. H., "Experimental Study on the Flexural Capacity of the Concrete-Filled Composite Beam with Exposed Top Flange", Journal of the Korean Society of Hazard Mitigation, Vol.17, No.4, pp.1-9, 2017
4 Kim, S. B., Hwangbo, C., Lee, T. K., Cho, H. S., & Kim, S. S., "The Shear Strength Evaluation of the New Shear Connector by Push-out Test", Journal of the Korean Society of Hazard Mitigation, Vol.14, No.1, pp.1-10, 2014   DOI
5 Kim, Y. J., Bae, J. H., Ahn, T. S., & Jang, D. W., "Push-out Test on Welded Angle Shear Connectors used in Composite Beams", Journal of Korean Society of Steel Construction, Vol.26, No.3, pp.155-167, 2014   DOI
6 Lee, M. H., Oh, M. H., Kim, Y. H., Jeong, S. C., & Kim, M. H., "Experimental Study on the Shear Capacity of Slim AU Composite Beam", Journal of Korean Association for Spatial Structures, Vol.17, No.3, pp.99-105, 2017   DOI
7 MOLIT, "Korea Building Code", Ministry of Land, Infrastructure and Transport, 2016.