• Title/Summary/Keyword: upper structures

Search Result 910, Processing Time 0.036 seconds

A Study on the Design and Strength Evaluation of the Pipe Support Structure and Hull Reinforcement (파이프 지지구조와 하부 보강의 설계와 강도 평가에 관한 연구)

  • Kim, Ul-Nyeon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.3
    • /
    • pp.187-199
    • /
    • 2019
  • In the case of gas carriers and oil tankers, pipes are installed on the upper deck as a moving passage to load LPG, LNG, crude oil, etc. Pipes used for loading or unloading liquid cargo in cargo holds are connected to the hull through support structures. However, many cases of hull damage have been reported where the various equipment and support structures are installed on the upper deck. It is assumed that not only the structural discontinuity where the hull and the pipe support structure meet, but also action due to the pipe loads and the hull girder bending moment are simultaneously affected. This paper deals with the design and strength evaluation of the support structure of pipes and cables installed on the upper deck of commercial ships and offshore structures. For these supporting structures, design conditions and working loads were defined. The design procedure was established through the structure analysis on the method of determining the member dimensions. A series of finite element analysis was performed on the factors to be considered in the design and the effects were discussed. The accuracy and design periods of the strength evaluation was improved and reduced by application of the automation program in the finite element analysis. It is also expected that the design reliability of the shipyard is improved.

Influence on the Movement of Fish by the Installation of Structures in Mountain Streams: Focused on Chinese Minnow (산지계류에 설치된 계상구조물이 어류의 이동에 미치는 영향: 버들치를 중심으로)

  • Ma, Ho-Seop;Park, Jae-Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.108 no.2
    • /
    • pp.224-232
    • /
    • 2019
  • The movement of fish to the upper and the lower parts of a mountain stream was investigated based on the installation of specific types of structures within the stream. The results indicated that as the flow rate increases after a rain, the height of the drop in an open-type structure, such as a concrete box, is decreased so that the floating fishes, such as the Chinese minnow fish, move relatively easily from the upper to the lower parts and from the lower to the upper parts of the stream. In contrast, the fishes released from an upper point of a wall-type structure with <1 m, such as rocks drop works and stone masonry for stream-grade stabilization, were trapped in the lower part of the stream and, even after the rainy season, it was difficult for the fish to move from the lower to the upper parts of the stream. In particular, the barrier-type structures ${\geq}3m$ limit the movement of fish, even when there are few drainage holes at the lower end of the dam, and there is no space for the fishes to communicate with each other, even when the flow rate is high; therefore, although the fish are active, they are restricted to move according to the type and characteristics of the structures. When installing structures in a mountain stream, the height of the structure must be low enough to allow the fish to communicate with each other or an open-type structure must be installed. The fish habitat and water conditions within the stream must be considered when designing the type and height of the in-stream structures.

Nonlinear Dynamic Response Characteristics with Variations in the Lower Stories of Mixed Building Structures (복합구조물의 하부층수 변화에 따른 비선형 동적응답특성)

  • 강병두;전대한;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.443-450
    • /
    • 2001
  • The Mixed building structures can be divided into three partition, namely, upper wall, lower frame, and transfer system which link two partitions. The purpose of this study is to investigate the nonlinear response characteristics of structures, as the stories of lower frame of mixed building structures changes. The recorded earthquake ground motions of EI Centro 1940 NS is adopted, and the maximum ground accelerations are adjusted to 55ga1, 110ga1, 220ga1, 330ga1. The conclusions of this study are the following. 1) The responses of model that the story of lower frame is one were different from those of other models. 2) The process of ductility hinge occurrence of member was ends of coupling beam of upper wall and ends of beam of lower frame in 55ga1, bases of shear wall on pit floor in 110ga1, and bases of column of 1F in 220ga1.

  • PDF

A Study on Natural Vibration Characteristics of Dome Structure According to Natural Frequency Ratio of Substructure (하부 구조의 고유 진동수비에 따른 돔 구조의 고유 진동 특성에 관한 연구)

  • Park, Kwang-Seob;Kim, Yun-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.75-82
    • /
    • 2018
  • Large space structures exhibit different natural vibration characteristics depending on the aspect ratio of structures such as half-open angle. In addition, since the actual large space structure is mostly supported by the lower structure, it is expected that the natural vibration characteristics of the upper structure and the entire structure will vary depending on the lower structure. Therefore, in this study, the natural vibration characteristics of the dome structure are analyzed according to the natural frequency ratio by controlling the stiffness of the substructure. As the natural frequency of the substructure increases, the natural frequency of the whole structure increases similarly to the natural frequency of the upper structure. Vertical vibration modes dominate at $30^{\circ}$ and $45^{\circ}$, and horizontal vibration modes dominate at $60^{\circ}$ and $90^{\circ}$.

Optimum design of viscous dampers to prevent pounding of adjacent structures

  • Karabork, Turan;Aydin, Ersin
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.437-453
    • /
    • 2019
  • This study investigates a new optimal placement method for viscous dampers between structures in order to prevent pounding of adjacent structures with different dynamic characteristics under earthquake effects. A relative displacement spectrum is developed in two single degree of freedom system to reveal the critical period ratios for the most risky scenario of collision using El Centro earthquake record (NS). Three different types of viscous damper design, which are classical, stair and X-diagonal model, are considered to prevent pounding on two adjacent building models. The objective function is minimized under the upper and lower limits of the damping coefficient of the damper and a target modal damping ratio. A new algorithm including time history analyses and numerical optimization methods is proposed to find the optimal dampers placement. The proposed design method is tested on two 12-storey adjacent building models. The effects of the type of damper placement on structural models, the critical period ratios of adjacent structures, the permissible relative displacement limit, the mode behavior and the upper limit of damper are investigated in detail. The results of the analyzes show that the proposed method can be used as an effective means of finding the optimum amount and location of the dampers and eliminating the risk of pounding.

OBSERVATION OF THE MAGNETIC DOMAIN IN THIN-FILM HEADS BY ELECTRON MICROSCOPY

  • Kobayashi, Kazuo
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.710-715
    • /
    • 1995
  • Magnetic domains were observed using an image lock-in technique for backscattered electron contrast (Type II) with a 200 kV scanning electron microscope. Backscattered electrons indicate a difference in magnetic domain structures at the upper and lower parts of the upper pole in thin-film heads, changing the acceleration voltage. With this method, it is also possible to observe the domain structure of the thin-film head pole through a 10 to $20\;\mu\textrm{m}$ protective layer, and the upper shield of the MR head through the coil in the resist, alumina overcoat, and upper pole.

  • PDF

Wind loads for high-solidity open-frame structures

  • Amoroso, Samuel D.;Levitan, Marc L.
    • Wind and Structures
    • /
    • v.14 no.1
    • /
    • pp.1-14
    • /
    • 2011
  • Open frame structures, such as those commonly found in industrial process facilities, are often densely occupied with process related equipment. This paper presents a method for estimating wind loads for high-solidity open frame structures that differs from current approaches, which accumulate wind load contributions from various individual structure components. The method considers the structure as a porous block of arbitrary plan dimension that is subject to wind from any direction. The proposed method compares favorably with wind tunnel test results for similar structures. The possibility of defining an upper bound force coefficient is also discussed.

Key technologies research on the response of a double-story isolated structure subjected to long-period earthquake motion

  • Liang Gao;Dewen Liu;Yuan Zhang;Yanping Zheng;Jingran Xu;Zhiang Li;Min Lei
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.17-30
    • /
    • 2024
  • Earthquakes can lead to substantial damage to buildings, with long-period ground motion being particularly destructive. The design of high-performance building structures has become a prominent focus of research. The double-story isolated structure is a novel type of isolated structure developed from base isolated structure. To delve deeper into the building performance of double-story isolated structures, the double-story isolated structure was constructed with the upper isolated layer located in different layers, alongside a base isolated structure for comparative analysis. Nonlinear elastoplastic analyses were conducted on these structures using different ground motion inputs, including ordinary ground motion, near-field impulsive ground motion, and far-field harmonic ground motion. The results demonstrate that the double-story isolated structure can extend the structural period further than the base isolated structure under three types of ground motions. The double-story isolated structure exhibits lower base shear, inter-story displacement, base isolated layer displacement, story shear, and maximum acceleration of the top layer, compared to the base isolated structure. In addition, the double-story isolated structure generates fewer plastic hinges in the frame, causes less damage to the core tube, and experiences smaller overturning moments, demonstrating excellent resistance to overturning and a shock-absorbing effect. As the upper isolated layer is positioned higher, the compressive stress on the isolated bearings of the upper isolated layer in the double-story isolated structure gradually decreases. Moreover, the compressive stress on the isolated bearings of the base isolated layer is lower compared to that of the base isolated structure. However, the shock-absorbing capacity of the double-story isolated structure is significantly increased when the upper isolated layer is located in the middle and lower section. Notably, in regions exposed to long-period ground motion, a double-story isolated structure can experience greater seismic response and reduced shock-absorbing capacity, which may be detrimental to the structure.

The Contribution of Pre-Existing Structures during the Structural Inversion in Cretaceous Sedimentary Rocks on Geoje Island, SE Korea

  • Francois Hategekimana;Mohammed S. M. Adam;Young-Seog Kim
    • Journal of the Korean earth science society
    • /
    • v.44 no.4
    • /
    • pp.275-290
    • /
    • 2023
  • Structural inversion refers to the reverse reactivation of extensional faults that influence basin shortening accommodated by contractional faults or folds. On the Korean peninsula, Miocene inversion structures have been found, but the Cretaceous rocks on Geoje Island may have undergone inversion as early as the Upper Cretaceous. To evaluate the structural inversion on Geoje Island, located on the eastern side of South Korea, and to determine the effects of preexisting weakness zones, field-based geometric and kinematic analyses of faults were performed. The lithology of Geoje Island is dominated by hornfelsified shale, siltstone, and sandstone in the Upper-Cretaceous Seongpori formation. NE and NW-oblique normal faults, conjugate strike-slip (NW-sinistral transpressional and E-W-dextral transtensional) faults, and NE-dextral transpressional faults are the most prominent structural features in Geoje Island. Structural inversion on Geoje Island was evidenced by the sinistral and dextral transpressional reactivation of the NW and NE-trending oblique normal faults respectively, under WNW-ESE/NW-SE compression, which was the orientation of the compressive stress during the Late Cretaceous to Early Cenozoic.

Analysis of Influence on Stream Water Quality by Soil Erosion Control Structures (사방공작물이 계류수질에 미치는 영향 분석)

  • Park, Jae-Hyeon;Kim, Choonsig
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.4
    • /
    • pp.571-577
    • /
    • 2013
  • This study was carried out to establish the construction guidelines of soil erosion control structures for a restoration of mountain stream with analysis of water quality around constructed soil erosion control structures in mountain streams. Water pH of the Uidong valleys in Bukhansan (Mt.) was similar between the constructed soil erosion control structures of lower stream areas [pH 6.53(6.25~6.82)] and the non-constructed areas of upper stream areas [pH 6.32(5.73~6.90)]. Mean concentration of dissolved oxygen was also similar between the constructed soil erosion control structures of lower steam areas [10.2 mg/L(9.9~10.4 mg/L)] and the non-constructed areas of upper stream areas [10.3 mg/L (9.6~10.6 mg/L)]. Mean electric conductivity was similar between the lower [$63.9{\mu}S/cm$ ($32.6{\sim}120.4{\mu}S/cm$)]a nd the upper stream areas [$62.2{\mu}S/cm$ ($40.3{\sim}89.5{\mu}S/cm$)]. Mean concentration of anions was also similar between the lower [15.94 mg/L (3.43~7.98 mg/L)] and the upper stream areas [14.51 mg/L (2.56~4.29 mg/L)]. Water pH of the Honggei valleys in Sancheong-gun was similar between the lower [pH 6.86(6.50~7.10)] and the upper stream areas [pH 6.89(6.61~7.12)]. Mean concentration of dissolved oxygen was also similar between the lower [11.9 mg/L(11.5~12.3 mg/L)] and the upper stream areas [12.2 mg/L (11.6~12.6 mg/L)]. Mean electric conductivity was similar between the lower [$633.4{\mu}S/cm$ ($31.6{\sim}34.6{\mu}S/cm$)] and the upper stream areas [$32.7{\mu}S/cm$ ($31.4{\sim}34.3{\mu}S/cm$)]. Mean concentration of anion was also similar to both stream areas [1.0 mg/L (0.1~2.2 mg/L)]. Water quality in the Uidong and the Honggei valleys was not significantly different between the constructed soil erosion control structures of lower stream areas and the non-constructed areas of upper stream areas. It will be needed to study the time-series analysis of water quality before and after the construction of soil erosion control structure the restoration of mountain streams because the water quality in mountain streams could be affected during the construction processes of structures.