• 제목/요약/키워드: upper diameter

검색결과 576건 처리시간 0.025초

분사펌프에 연결된 구동관로 위치변화에 따른 유동특성 (Flow Characteristics of Driven Nozzle Position Change in the Connected Injection Pump)

  • 손현철;박길문;고현선;이행남
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.215-224
    • /
    • 2009
  • Analysis for various driven nozzle position changes. The analysis was done for different Reynolds number in entrance region of jet-pump and for several diameter ratios of driven nozzle. (1) The largest absorption energy was found at the point s=1 in condition of diameter ratio 1:3.21 and point s=0.5 in condition of diameter ratio 1:2.25. (2) The absorption energy was not related to the change of entrance velocity and the driven nozzle position having the largest absorption energy was function for cross section ratio. (3) As the position of driven nozzle moves to the downstream, the absorption energy gets weaker. Because the energy from swirl was lost at the cross section gets smaller. (4) As the position of driven nozzle moves to the downstream, the injection energy leans to the upper direction wall and as the Reynolds number increase, the lean phenomenon is more distinct. (5) The flow quantity of driven nozzle, the diameter ratio 1:3.21, was 32% higher than that of 1 : 2.25 and as the inlet velocity gets faster the efficiency decreased. And as the cross section of the driven nozzle increases.

대구경 PHC말뚝 및 대구경 복합말뚝($\phi$1,000mm) 지지력 산정에 관한 연구 (Bearing capacity of large diameter PHC pile and large diameter composite pile)

  • 신윤섭;박재현;황의성;조성한;정문경;이진영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.351-359
    • /
    • 2010
  • Large PHC piles with a diameter of 1,000mm or larger were recently introduced for the first time in Korea. This paper presents full-scale static and dynamic pile load tests performed on two 1,000mm PHC piles and two composite piles with steel pipe piles of the same diameter in the upper portion, installed by driving and pre-boring. The objectives of the tests include evaluating pile drivability, load-settlement relation, allowable bearing capacity, and the stability of mechanical splicing element for the composite pile(a.k.a. non-welding joint). The performance of the large diameter PHC piles were thought to be satisfactory compared to that of middle sized PHC piles with a long history of successful applications in the domestic and foreign markets.

  • PDF

상계법과 유한요소법을 이용한 확관금형 설계 (Design of Pipe Expanding Die by Upper Bound Analysis and Finite Element Method)

  • 조용일;김승환;추연근;조해용
    • 한국기계가공학회지
    • /
    • 제19권5호
    • /
    • pp.98-104
    • /
    • 2020
  • Pipe expansion involves various methods to enlarge the diameter of the pipes with the use of a mandrel or punch placed inside the pipe. In this study, the upper bound method was used to analyze the pipe expanding process as well as design a die. A kinematically admissible velocity field was derived for the upper bound analysis with the occurrence of pipe thinning during the expansion factored in. The analysis confirms that a semi-cone angle of the punch between 15ween pip is most advantageous for pipe expansion. The results of the upper bound analysis, which were also consistent with those of the FEM, can be useful for the design of a pipe expansion die.

교량기초 하부에 위치한 터널의 지보방법에 따른 변위거동 (Displacement Behavior of Tunnel under Bridge Abutment due to Supporting Systems)

  • 유남재;박병수;정길수;김승렬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.613-620
    • /
    • 2005
  • This research is experimental paper to prepare the structural safety of the upper bridge for support type on tunnel and the effect of settlement. Unit weight test and uni-axial compression test have been performed to simulate the physical property of foundation on the tunnel. Tunnel model of slip form type for centrifuge model has been developed to performed the tunnel excavation while field stress is activated. And the support type of tunnel such as umbrella arch method and large diameter steel pipe reinforce method has been tested for the centrifuge model. After the analysis of experiment, results show that internal displacement of large diameter steel pipe reinforce method is smaller than that of the umbrella arch method.

  • PDF

터널의 지보방법에 관한 원심모형실험(遠心模型實驗) (The Support Types of the Tunnel for Centrifuge Model)

  • 유남재;이명욱;박병수
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.199-209
    • /
    • 2002
  • This research is experimental thesis to prepare the structural safety of the upper bridge for support type on tunnel and the effect of settlement. Unit weight test and uni-axial compression test have been performed to simulate the physical property of foundation on the tunnel. Tunnel model of slip form type for centrifuge model has been developed to performed the tunnel excavation while field stress is activated. And the support type of tunnel such as umbrella arch method and large diameter steel pipe reinforce method has been tested for the centrifuge model. After the analysis of experiment, results show that internal displacement of large diameter steel pipe reinforce method is smaller than that of the umbrella arch method.

  • PDF

Effect of constitutive equations on theoretical analysis in melt spinning process

  • Kim, Seong-Cheol;Oh, Tae-Hwan;Han, Sung-Soo;Lyoo, Won-Seok
    • Korea-Australia Rheology Journal
    • /
    • 제21권3호
    • /
    • pp.149-153
    • /
    • 2009
  • Profile development of the melt spinning process of poly(ethylene terephthalate) (PET) was simulated by a numerical method under the consideration of two constitutive equations of Newtonian and upper convected Maxwell (UCM) models. The viscoelastic characteristics of the polymer were considered via UCM constitutive equation that considered relaxation time as a function of temperature and molecular weight. The UCM model predicted the diameter profile better than the Newtonian, while velocity development was slower than the Newtonian model. Viscoelasticity played an important role in accurately predicting diameter profile. However, even though neck-like deformation was observed in the UCM model, the exact position of the deformation under high speed spinning was not obtained.

On Diameter, Cyclomatic Number and Inverse Degree of Chemical Graphs

  • Sharafdini, Reza;Ghalavand, Ali;Ashrafi, Ali Reza
    • Kyungpook Mathematical Journal
    • /
    • 제60권3호
    • /
    • pp.467-475
    • /
    • 2020
  • Let G be a chemical graph with vertex set {v1, v1, …, vn} and degree sequence d(G) = (degG(v1), degG(v2), …, degG(vn)). The inverse degree, R(G) of G is defined as $R(G)={\sum{_{i=1}^{n}}}\;{\frac{1}{deg_G(v_i)}}$. The cyclomatic number of G is defined as γ = m - n + k, where m, n and k are the number of edges, vertices and components of G, respectively. In this paper, some upper bounds on the diameter of a chemical graph in terms of its inverse degree are given. We also obtain an ordering of connected chemical graphs with respect to the inverse degree.

함진기체의 배출에 미치는 금망 충진물의 영향 (Effects of Screen Packing Materials an Gas Discharge Dust Containing)

  • 홍영호;함영민
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.120-126
    • /
    • 1993
  • This work was carried out to investigate the effects of solid mass flow rate, mean particle diameter and mesh number of screen packing material on minimum carrying velocity, which defined as the superficial gas velocity of the upper limit of chocking phenomenon. Vertical pneumatic conveying was studied on a 4.6cm 1. D. pipe, 180cm in length. Experiments were performed in both the empty and the screen-packed pipe. It was also examined the effect of superficial gas velocity, solid mass flow, mean particle diameter, and mesh number of packing material on pressure drop. Minimum carrying velocity in screen packed-pipe was lower than that in an empty pipe. besides minimum carrying velocity was decreased with increase in mesh number of screen packing material. The pressure drop In vortical packed-pipe was Increased with superficial gas velocity, mean particle diameter, and mesh number of screen packing material.

  • PDF

링 압축 시험을 이용한 레이저 텍스처링 표면처리 패턴별 윤활성능 평가 (Evaluation of Lubrication Performance by Laser Texturing Surface Treatment Patterns through Ring Compression Tests)

  • 최지석;송우진
    • 소성∙가공
    • /
    • 제33권4호
    • /
    • pp.291-300
    • /
    • 2024
  • To compare the lubrication performance improvement of different laser texturing surface treatment patterns, ring-shaped specimens were prepared by processing line and dot patterns using a fiber laser device. Ring compression tests were conducted to compare the reduction rates of the inner diameter corresponding to the same height reduction of the specimens. Laser processing conditions were set to create patterns with a depth of 9㎛ and a width of 45㎛. Ring specimens were processed with varying spacings between dots and lines. The forging lubricant TECTYL FORM CF 351S was uniformly applied to the upper and lower compression tools, and the rings were compressed by 40% using a hydraulic press, after which the inner diameter was measured. The comparison of inner diameter reduction rates indicated that pattern processing improves lubrication performance, with line patterns being more effective than dot patterns in enhancing lubrication performance.

상부유입식 전기 Cyclone-Bag Filter의 특성 (Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet)

  • 여석준
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF