• Title/Summary/Keyword: upper GI series

Search Result 13, Processing Time 0.027 seconds

Evaluation of Commercialized Barium Products for Upper GI Contrast Study in Beagle Dogs (비글견에서 상부 위장관 조영술을 통한 상용화된 바륨 조영제의 평가)

  • Choi, Ho-Jung;Hwang, Yoon-Tae;Lee, Ki-Ja;Kim, Hwan-Cheol;Choi, Ji-Young;Chang, Jin-Hwa;Lee, Hee-Chun;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.87-93
    • /
    • 2011
  • Upper gastrointestinal contrast studies were performed to compare the quality of images using two different commercialized barium products in 10 healthy beagle dogs of each group; 30% barium suspension in group 1, and 35% dilute barium suspension in group 2. Contrast media were administered through gastric tube at a dose rate of 10 ml/kg in all groups. All procedures were evaluated by three criteria: the quality of the images obtained, the transit time and the distensibility of the bowel. The imaging in group 1 showed good image quality, a rapid transit time, and good distensibility of bowel loop.

Infantile Hypertrophic Pyloric Stenosis -Clinical Differences between Premature and Full-term Infants (미숙아와 만삭아에서의 비후성 유문 협착증의 임상적 차이)

  • Lee, Suk-Koo;Kim, Seong-Hwan;Lee, Woo-Yong;Kim, Hyun-Hahk
    • Advances in pediatric surgery
    • /
    • v.4 no.1
    • /
    • pp.34-38
    • /
    • 1998
  • Infantile hypertrophic pyloric stenosis(IHPS) is common in full-term babies, and relatively rare in prematures. The diagnosis of IHPS in premature infants may be obscured because of the lack of classic symptoms and signs and the absence of the standard criteria for ultrasonic diagnosis. The purpose of this study is to discover the clinical differences between premature and full-term infants with pyloric stenosis, and determine the appropriate diagnostic methods for early diagnosis in premature infants. The clinical records of 52 IHPS patients who had been operated upon from October, 1994 to April, 1997 were reviewed. The incidence of IHPS in premature infants was 25 %. The onset of symptom was 4.7 weeks of age in premature, and 2.9 weeks in full-term babies. Diagnosis was established by typical symptoms. signs. and diagnostic imaging studies. In two premature infants, diagnosis was confirmed by upper gastrointestinal(GI) series, because ultrasonography did not meet the diagnostic criteria. Two premature infants initially diagnosed as gastroesophageal reflux by esophagography. were found to have IHPS by upper GI series. For the diagnosis of IHPS, a new set of criteria for premature babies has to be developed.

  • PDF

Usefullness of CT Gastrography and Vurtual Gastroscopy using Computed Tomography in Detection of Gastric Cancer (위암 진단에 있어서의 CT 위장 조영술과 상부위장관 조영술과의 비교)

  • Baik Yong Hae;Lee Soon Jin;Lee Ji Yun;Noh Jae Hyung;Sohn Tae Sung;Kim Sung;Kim Yong Il
    • Journal of Gastric Cancer
    • /
    • v.3 no.4
    • /
    • pp.195-200
    • /
    • 2003
  • Purpose: Advancement of computed tomography (CT) hardware and software has allowed thin section scanning and reconstruction of fascinating 2-dimentional (2D) and 3- dimentional (3D) images. Especially, the reconstruction of 3D images of gastrointestinal tract has been used in the detection and diagnosis of pre-malignant and malignant diseases. To compare the efficacy of CT gastrography with conventional upper gastrointenstinal series (UGIs) in gastric cancer patients. Materials and Methods: During Nov. 2002 and Mar. 2003, twenty-seven patients who had gastric cancer received both double contrast upper GI series and CT gastrography prior to radical surgery. Among these patients, nineteen had early gastric cancer (EGC) and 8 had advanced gastric cancer (AGC). Fifteen patients were male and 12 were female. The mean age was 54 yrs (range, $27\∼75$ yrs). The patients were placed on NPO and Stomach was distended with gas in fasting state prior to CT scanning. Double contrast upper GI series were performed as routine manual. CT scan was conducted in all patients using 8 or 16-channel multidetector CT in this study. The collimation and reconstruction for CT scanning were set at 2.5 mm and 1.25 mm, respectively. CT scanning was performed in the supine position. For image processing, CT gastrography, in which raysum and surface rendering images were constructed, virtual and 2D image in coronal and sagittal images were performed. The detectability of gastric cancer was assessed between UGIs and CT gastrography. Results: In AGCs, the detection rate of cancer using CT gastrography and virtual gastroscopy was higher than EGC cases. However, CT gastrography and virtual gastroscopy showed less favorable results than UGIs. Even though only a small number of cases had been studied, we might conclude that CT gastrography and virtual gastroscopy could replace UGIs in the detection of AGC cases. Conclusion: The detection rate used with CT gastrography and Virtual gastroscopy is not better than that of UGIs in early gastric cancer, however, in advanced gastric cancer cases, it is nearly equal to that of UGIs.

  • PDF

Performance Characteristics and Improvement Suggestion of Individual Sewage Treatment in Kyangan Watershed (경안천 유역 소규모 오수처리시설의 처리특성 및 효율개선방안)

  • Jang, Young-ho;Kim, Keug Tae;Jahng, Deok-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.816-821
    • /
    • 2010
  • It has been achieved 109.1 kg/d of BOD reduction that is equivalent to the amount of BOD loading discharged from 21,880 persons and dramatic decrease of the fallout ratio against water quality of effluent, from 42% to 9%, through technical support on ISTPs to be applied by the ISMSGA at the upper area of Geongan river in Yong-In city. It was clearly revealed that the most efficient configuration for ISTP was a series of anaerobic tank, equalization basin, aerobic tank, sedimentation tank, and then effluent tank. Also, the major causes on the fallout ratio of ISTP resulted in the lack of management (67.5%) and imperfect facilities (32.5%). Then, when compared the quantity of water supply with the design capacity of ISTP, the design capacity was estimated as 1.8 or 2.4 folds larger than the real quantity of water supply so that it is essential to punctually consider the key factors such as an estimation methods, the specificity of commission operator and construction by high systematic technologies to improve the water quality for the future.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.301-305
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelfth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.391-394
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelveth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

Sensitivity of Parameters for Elasto-plastic Constitutive Model (탄.소성 구성 모델의 초질매개변수 예민성)

  • Jeong, Jin-Seop;Kim, Chan-Gi;Lee, Mun-Su
    • Geotechnical Engineering
    • /
    • v.8 no.2
    • /
    • pp.81-96
    • /
    • 1992
  • This paper dealt with the influence of experimental error generated inevitably during performing experiments on the granular soil behaviour analysis selecting Lade's Single Work-Hardening constitutive model. Several isotropic compression-expansion tests and a series of drained conventional triaxial tests with various confining pressures for Baekma river sands were performed and the values of parameters for the above model were determined using computer program developed for this study based on regression analysis. By finding the range of the upper and lower bound for deviator stress and volumetric strain versus axial strain dependant on the increase and decrease of the standard deviation from mean value of parameters, sensitivities of all the parameters were examined. Practical use of program to determine the parameters and capability to predict the behaviour of granular soil by Lade's Single Work -Hardening model verified.

  • PDF

A Novel Bottom-Gate Poly-Si Thin Film Transistors with High ON/OFF Current Ratio (ON/OFF 전류비를 향상시킨 새로운 bottom-gate 구조의 다결정 실리콘 박막 트랜지스터)

  • Jeon, Jae-Hong;Choe, Gwon-Yeong;Park, Gi-Chan;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.315-318
    • /
    • 1999
  • We have proposed and fabricated the new bottom-gated polycrystalline silicon (poly-Si) thin film transistor (TFT) with a partial amorphous-Si region by employing the selective laser annealing. The channel layer of the proposed TFTs is composed of poly-Si region in the center and a-Si region in the edge. The TEM image shows that the local a-Si region is successfully fabricated by the effective cut out of the incident laser light in the upper a-Si layer. Our experimental results show that the ON/OFF current ratio is increased significantly by more than three orders in the new poly-Si TFT compared with conventional poly-Si TFT. The leakage current is decreased significantly due to the highly resistive a-Si re TFTs while the ON-series resistance of the local a-Si is reduced significantly due to the considerable inducement of electron carriers by the positive gate bias, so that the ON-current is not decreased much.

  • PDF

GIS-based review of Goguryeo's defense system during the Gungnaeseong Period with the focus on the upper and middle reaches of the Amnok River and the mid-stream region of the Liohe River (GIS를 활용한 고구려 국내성 시기의 관방체계 검토 - 압록강 중상류~요하 중류를 중심으로 -)

  • Hong, Balgeum;Kang, Dongseok
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.260-279
    • /
    • 2021
  • The Goguryeo kingdom established a unique defense system centered on a series of mountain fortresses. However, modern-day studies on its defense system have tended to focus on how they were positioned and generally consist of little more than individual surveys or introductions to the relevant materials, leaving much to be desired. This study attempts to extend the scope of studies about fortresses dating back to the Goguryeo period, taking into account the limitations of the available materials. As such, this study reviews the defense system of Goguryeo during the Gungnaeseong Period (i.e., the period when Gungnaeseong was the capital of Goguryeo) using the GIS system, with the focus on fortresses that are thought to have been built in the area extending from the middle and upper reaches of the Amnok River to the mid-stream region of the Liohe River, based on the aforementioned studies. The results of the study are as follows. First, the major roads built during the Gungnaeseong Period were as stated in the foregoing studies to some extent. Researchers believed that during the middle period of the dynasty, a major road ran along the Suzihe, Fuer and Xinkai rivers before finally reaching Jian. The study found that fortified walls and fortress strongholds were built along this road. Second, there were seven fortresses between the middle and upper reaches of the Amnokgang River and the midstream region of the Liaohe River. A primary defense line was closely established between the strongholds and the nearby walls, with secondary and tertiary defense lines established more loosely and encompassing a much wider area. Third, regarding the defense system along the major roads, the Choejinbosanseong, Goisanseong and Cheolbaesanseong fortresses served as strongholds along the 60-kilometer-long primary defense line, with 80-kilometer-long secondary and tertiary defense lines set up behind it. The final 120-kilometer-long defense line of the capital was established along with the Onyeosanseong Fortress, while a stumbling block was set up close to the capital as a defense system, rather than building a fortified wall. To summarize, a primary defense system was established centered on a series of fortresses, with each stronghold maintaining a closely-knit defense system in connection with other nearby strongholds to repel invaders.

Development of an Improved Point Load Apparatus (개량형 점하중강도시험기의 개발)

  • Kim, Yong-Phil;Um, Jeong-Gi
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.473-478
    • /
    • 2009
  • The accuracy of point load apparatus is depend on point to point coaxial fitting. Also, the estimation of applied point load using the pressure gauge frequently lead to erroneous results. An improved point load apparatus has been developed in this study by mounting linear bearing on polished support rod, and eccentric error of point to point axis has been sustained less than 0.1 mm even under series of extreme work load conditions. Two digital displacement gauges are attached to measure the distance from point to point with sample specimen. A load cell mounted at the end of upper conical platen measure the applied net load on sample instead of preassure gauge. Total of 107 point load tests has been achieved to assure the quality and performance of developed apparatus. This exercise turned out to be successful.