• Title/Summary/Keyword: unknown parameters

Search Result 880, Processing Time 0.025 seconds

Load Distribution Factors for Two-Span Continuous I-Girder Bridges (2경간 연속 I-형교의 하중분배계수)

  • Back, Sung Yong;Shin, Gi Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.2
    • /
    • pp.233-245
    • /
    • 2007
  • Previous finite element studies have shown that AASHTO Standard load distribution factor (LDF) equations appear to be conservative for longer spans and larger girder spacing, but too permissible for short spans and girder spacing. AASHTO LRFD specification defines the distribution factor equation for girder spacing, span length, slab thickness, and longitudinal stiffness. However, this equation requires an iterative procedure to correctly determine the LDF value due to an initially unknown longitudinal stiffness parameter. This study presents a simplified LDF equation for interior and exterior girders of two-span continuous I-girder bridges that does not require an iterative design procedure. The finite element method was used to investigate the effect of girder spacing, span length, slab thickness, slab width, and spacing and size of bracing. The computer program, GTSTRUDL, was used to idealize the bridge superstructures as the eccentric beam model, the concrete slab by quadrilateral shell elements, steel girders by space frame members, and the composite action between these elements by rigid links. The distribution factors obtained from these analyses were compared with those from the AASHTO Standard and LRFD methods. It was observed through the parametric studies that girder spacing, span length, and slab thickness were the dominant parameters compared with others. The LRFD distribution factor for the interior girder was found to be conservative in most cases, whereas the factor for the exterior girder to be unconservative in longer spans. Furthermore, a regression analysis was performed to develop simplified LDF formulas. The formulas developed in this study produced LDF values that are always conservative to those from the finite element method and are generally smaller than the LDF values obtained from the AASHTO LRFD specification. The proposed simplified equation will assist bridge engineers in predicting the actual LDF in two-span continuous I-girder bridges.

Evaluation of Diagnostic Performance of a Polymerase Chain Reaction for Detection of Canine Dirofilaria immitis (개 심장사상충을 진단하기 위한 중합연쇄반응검사 (PCR)의 진단적 특성 평가)

  • Pak, Son-Il;Kim, Doo
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Diagnostic performance of polymerase chain reaction (PCR) for detecting Dirofilaria immitis in dogs was evaluated when no gold standard test was employed. An enzyme-linked immunosorbent assay test kit (SnapTM, IDEXX, USA) with unknown parameters was also employed. The sensitivity and specificity of the PCR from two-population model were estimated by using both maximum likelihood using expectation-maximization (EM) algorithm and Bayesian method, assuming conditional independence between the two tests. A total of 266 samples, 133 samples in each trial, were randomly retrieved from the heartworm database records during the year 2002-2004 in a university animal hospital. These data originated from the test results of military dogs which were brought for routine medical check-up or testing for heartworm infection. When combined 2 trials, sensitivity and specificity of the PCR was 96.4-96.7% and 97.6-98.8% in EM and 94.4-94.8% and 97.1-98% in Bayesian. There were no statistical differences between estimates. This finding indicates that the PCR assay could be useful screening tool for detecting heartworm antigen in dogs. This study was provided further evidences that Bayesian approach is an alternative approach to draw better inference about the performance of a new diagnostic test in case when either gold test is not available.

Fuzzy sliding mode controller design for improving the learning rate (퍼지 슬라이딩 모드의 속도 향상을 위한 제어기 설계)

  • Hwang, Eun-Ju;Cho, Young-Wan;Kim, Eun-Tai;Park, Mignon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.6
    • /
    • pp.747-752
    • /
    • 2006
  • In this paper, the adaptive fuzzy sliding mode controller with two systems is designed. The existing sliding mode controller used to $approximation{\^{u}}(t)$ with discrete sgn function and sat function for keeping the state trajectories on the sliding surface[1]. The proposed controller decrease the disturbance for uncertain control gain and This paper is concerned with an Adaptive Fuzzy Sliding Mode Control(AFSMC) that the fuzzy systems ate used to approximate the unknown functions of nonlinear system. In the adaptive fuzzy system, we adopt the adaptive law to approximate the dynamics of the nonlinear plant and to adjust the parameters of AFSMC. The stability of the suggested control system is proved via Lyapunov stability theorem, and convergence and robustness properties ate demonstrated. Futhermore, fuzzy tuning improve tracking abilities by changing some sliding conditions. In the traditional sliding mode control, ${\eta}$ is a positive constant. The increase of ${\eta}$ has led to a significant decrease in the rise time. However, this has resulted in higher overshoot. Therefore the proposed ${\eta}$ tuning AFSMC improve the performances, so that the controller can track the trajectories faster and more exactly than ordinary controller. The simulation results demonstrate that the performance is improved and the system also exhibits stability.

Characteristics of Measurement Errors due to Reflective Sheet Targets - Surveying for Sejong VLBI IVP Estimation (반사 타겟의 관측 오차 특성 분석 - 세종 VLBI IVP 결합 측량)

  • Hong, Chang-Ki;Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.325-332
    • /
    • 2022
  • Determination of VLBI IVP (Very Long Baseline Interferometry Invariant Point) position with high accuracy is required to compute local tie vectors between the space geodetic techniques. In general, reflective targets are attached on VLBI antenna and slant distances, horizontal and vertical angles are measured from the pillars. Then, adjustment computation is performed by using the mathematical model which connects measurements and unknown parameters. This indicates that the accuracy of the estimated solutions is affected by the accuracy of the measurements. One of issues in local tie surveying, however, is that the reflective targets are not in favorable condition, that is, the reflective sheet target cannot be perfectly aligned to the instrument perpendicularly. Deviation from the line of sight of an instrument may cause different type of measurement errors. This inherent limitation may lead to incorrect stochastic modeling for the measurements in adjustment computation procedures. In this study, error characteristics by measurement types and pillars are analyzed, respectively. The analysis on the studentized residuals is performed after adjustment computation. The normality of the residuals is tested and then equal variance test between the measurement types are performed. The results show that there are differences in variance according to the measurement types. Differences in variance between distances and angle measurements are observed when F-test is performed for the measurements from each pillar. Therefore, more detailed stochastic modeling is required for optimal solutions, especially in local tie survey.

Hydrogeochemistry of Groundwater Occurring in Complex Geological Environment of Yeongdong Area, Chungbuk, Korea (충북 영동군 복합 지질지역에서 산출되는 지하수의 수리지화학적 특성)

  • Moon, Sang-Ho
    • Economic and Environmental Geology
    • /
    • v.50 no.6
    • /
    • pp.445-466
    • /
    • 2017
  • Yeongdong area is located in the contact zone between central southeastern Ogcheon belt and Yeongnam massif, in which Cretaceous Yeongdong basin exists. Therefore, the study area has complex geological environment of various geological age and rock types such as Precambrian metamorphic rocks, age-unknown Ogcheon Supergroup, Paleozoic/Mesozoic sedimentary rocks, Mesozoic igneous rocks and Quaternary alluvial deposits. This study focuses on the link between the various geology and water type, and discussed the source of some major ions and their related water-rock interaction. For this study, the field parameters and ion concentrations for twenty alluvial/weathered and eighty bedrock aquifer wells were used. Statistical analysis indicates that there was no significant differences in groundwater quality between wet and dry seasons. Although various types were observed due to complex geology, 80 to 84 % of samples showed $Ca-HCO_3$ water type. Some wells placed in alluvial/weathered aquifers of Precambrian metamorphic and Jurassic granitic terrains showed somewhat elevated $NO_3$ and Cl concentrations. $Mg-HCO_3$ typed waters prevailed in Cretaceous Yeongdong sedimentary rocks. The deeper wells placed in bedrock aquifers showed complicated water types varying from $Ca-HCO_3$ through $Ca-Cl/SO_4/NO_3$ to $Na-HCO_3$ and Na-Cl type. Groundwater samples with $Na-HCO_3$ or Na-Cl types are generally high in F concentrations, indicating more influences of water-rock interaction within mineralized/hydrothermal alteration zone by Cretaceous porphyry or granites. This study revealed that many deep-seated aquifer had been contaminated by $NO_3$, especially prominent in Jurassic granites area. Based on molar ratios of $HCO_3/Ca$, $HCO_3/Na$, Na/Si, it can be inferred that Ca and $HCO_3$ components of most groundwater in alluvial/weathered aquifer wells were definitely related with dissolution of calcite. On the other hand, Ca and $HCO_3$ in bedrock aquifer seem to be due to dissolution of feldspar besides calcite. However, these molar ratios require other mechanism except simple weathering process causing feldspar to be broken into kaolinite. The origin of $HCO_3$ of some groundwater occurring in Cretaceous Yeongdong sedimentary rock area seems to be from dissolution of dolomite($MgCO_3$) or strontianite($SrCO_3$) as well.

The Study on New Radiating Structure with Multi-Layered Two-Dimensional Metallic Disk Array for Shaping flat-Topped Element Pattern (구형 빔 패턴 형성을 위한 다층 이차원 원형 도체 배열을 갖는 새로운 방사 구조에 대한 연구)

  • 엄순영;스코벨레프;전순익;최재익;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.667-678
    • /
    • 2002
  • In this paper, a new radiating structure with a multi-layered two-dimensional metallic disk array was proposed for shaping the flat-topped element pattern. It is an infinite periodic planar array structure with metallic disks finitely stacked above the radiating circular waveguide apertures. The theoretical analysis was in detail performed using rigid full-wave analysis, and was based on modal representations for the fields in the partial regions of the array structure and for the currents on the metallic disks. The final system of linear algebraic equations was derived using the orthogonal property of vector wave functions, mode-matching method, boundary conditions and Galerkin's method, and also their unknown modal coefficients needed for calculation of the array characteristics were determined by Gauss elimination method. The application of the algorithm was demonstrated in an array design for shaping the flat-topped element patterns of $\pm$20$^{\circ}$ beam width in Ka-band. The optimal design parameters normalized by a wavelength for general applications are presented, which are obtained through optimization process on the basis of simulation and design experience. A Ka-band experimental breadboard with symmetric nineteen elements was fabricated to compare simulation results with experimental results. The metallic disks array structure stacked above the radiating circular waveguide apertures was realized using ion-beam deposition method on thin polymer films. It was shown that the calculated and measured element patterns of the breadboard were in very close agreement within the beam scanning range. The result analysis for side lobe and grating lobe was done, and also a blindness phenomenon was discussed, which may cause by multi-layered metallic disk structure at the broadside. Input VSWR of the breadboard was less than 1.14, and its gains measured at 29.0 GHz. 29.5 GHz and 30 GHz were 10.2 dB, 10.0 dB and 10.7 dB, respectively. The experimental and simulation results showed that the proposed multi-layered metallic disk array structure could shape the efficient flat-topped element pattern.

Nasal Continuous Airway Pressure Titration Unmasks Periodic Limb Movements in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술에 따른 주기성 사지운동증의 표출)

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.5 no.1
    • /
    • pp.103-110
    • /
    • 1998
  • Objectives : High co-morbidity of periodic limb movements during sleep(PLMS) and obstructive sleep apnea syndrome(OSAS) is well known and their incidences tend to increase in the elderly. Previous studies have inconsistently rep0l1ed increase or no change of periodic limb movement index(PLMI) by nasal continuous positive airway pressure(CPAP) in OSAS without analyzing possible variables affecting PLMI. We attempted to examine PLMI change evoked during CPAP titration and also factors affecting it in OSAS. Methods : Twenty-nine OSAS patients(M:F=26:3, mean age: $51.6{\pm}10.6\;yrs$) without other sleep disorders except for PLMS were selected, based on the nocturnal (baseline) polysomnograhy. Another night of noctumal polysomnography was performed for CPAP pressure titration. We compared between those two nights PLMI, mean and lowest $SaO_2$, and sleep variables. We also calculated PLMI differences between baseline and CPAP nights, named as delta PLMI (value of CPAP night PLMI minus value of baseline night PLMI). Correlations were calculated between delta PLMI and factors such as age, body mass index, applied CPAP pressure, baseline night values of respiratory disturbance index, mean and lowest $SaO_2$, and sleep parameter differences between baseline and CPAP nights. Results : Decrease of RDI(p<.01) and increase in mean and lowest $SaO_2$ (p<.05, p<.01) were observed during CPAP night. No sleep parameters showed significant change except for the decrease of total stage 1 sleep%(p<.01) during CPAP night. Ten out of 29 patients showed PLMI increase, while the other 19 patients showed either no change(n=14) or even PLMI decrease(n=5) during CPAP night. The 10 patients showing PLMI increase during CPAP night showed a significant positive correlation between delta PLMI and baseline night RDI(p<.05), which meant that PLMI increase was found to be more prominent in higher RDI patients than in lower RDI ones. There were no significant correlations between delta PLMI and other factors in the other 19 patients. Conclusions : We suggest that during the baseline night PLMS would have been underscored and/or masked due to the overlapping of PLMS and apneas/hypopneas or the arousals induced by apneas/hypopneas. Despite its still unknown mechanism, the CPAP application may unmask PLMS and increase PLMI in a subgroup of OSAS patients. It needs to be evaluated further whether the chronic CPAP use sustains the above finding.

  • PDF

Microsatellite Instability in Non-Small Cell Lung Cancer (비소세포폐암에서 Microsatellite Instability)

  • Jeon, Hyo-Sung;Kim, Jeong-Ran;Son, Ji-Woong;Park, Sun-Ha;Park, Tae-In;Kim, Chang-Ho;Kim, In-San;Jung, Tae-Hoon;Park, Jae-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.24-32
    • /
    • 2000
  • Purpose: Microsatellite instability(MSI) is frequently used as an indicator of microsatellite mutator phenotype(MMP) tumors. MSI has been observed in a percentage of non-small cell lung cancer(NSCLC). However, its role in tumorigenesis of NSCLC remains unknown. The frequency and pattern of MSI in NSCLC were evaluated and clinical parameters of MSI-positive tumors with those of MSS(microsatellite stable) tumors were compared. Materials and Methods: Twenty surgically resected NSCLCs were analyzed for 15 microsatellite markers located at chromosomes 3p and 9p. The peripheral blood lymphocytes of patients were used as the source of the normal DNA. Results: 1) Of 20 cases, 8(40%) demonstrated MSI. 2) Instability was observed more frequently in tri- and tetra-nucleotide repeats than in dinucleotide repeats. In all cases, instability appeared as a shift of individual allelic bands. 3) LDH was observed in 10(50%) of 20 tumors analyzed. 4) Of 20 cases, MSI-H tumor(showing MSI in the majority of markers) was absent. There were 5 MSI-L tumors(showing MSI in a greater than 10% of markers). 5) No significant difference was observed between MSI-L tumors and MSI-negative tumors in terms of clinicopathologic features such as pack-year history of smoking, histologic subtype, and(delete) stage of disease. There was also no significant difference in the incidence of LDH in relation to the status of MSI. Conclusion: These data strongly suggest that MSI plays different roles in lung and colon cancer. MMP pathway appears to be far less important in the tumorigenesis of NSCLC, caused mainly by cigarette smoke, with little familial tendency.

  • PDF

Change in Potential Productivity of Rice around Lake Juam Due to Construction of Dam by SIMRIW (벼 생장모형 SIMRIW를 이용한 주암호 건설에 따른 주변지역의 벼 잠재생산성 변이 추정)

  • 임준택;윤진일;권병선
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.6
    • /
    • pp.729-738
    • /
    • 1997
  • To estimate the change in rice productivity around lake Juam due to construction of artificial lake, growth, yield components and yield of rice were measured at different locations around lake Juam for three years from 1994 to 1996. Automated weather stations(AWS) were installed nearby the experimental paddy fields, and daily maximum, average and minimum temperature, solar radiation, relative humidity, and precipitation were measured for the whole growing period of rice. Plant height, number of tillers, leaf area and shoot dry weight per hill were observed from 8 to 10 times in the interval of 7 days after transplanting. Yield and yield components of rice were observed at the harvest time. Simulation model of rice productivity used in the study was SIMRIW developed by Horie. The observed data of rice at 5 locations in 1994, 3 locations in 1995 and 4 locations in 1996 were inputted in the model to estimate the unknown parameters. Comparisons between observed and predicted values of shoot dry weights, leaf area indices, and rough rice yield were fairly well, so that SIMRIW appeared to predict relatively well the variations in productivity due to variations of climatic factors in the habitat. Climatic elements prior to as well as posterior to dam construction were generated at six locatons around lake Juam for thirty years by the method of Pickering et al. Climatic elements simulated in the study were daily maximum and minimum temperature, and amount of daily solar radiation. The change in rice productivity around lake Juam due to dam construction were estimated by inputting the generated climatic elements into SIMRIW. Average daily maximum temperature after dam construction appeared to be more or less lower than that before dam construction, while average daily minimum temperature became higher after dam construction. Average amount of daily solar radiation became lower with 0.9 MJ $d^{-1}$ after dam construction. As a result of simulation, the average productivity of habitats around lake Juam decreased about 5.6% by the construction of dam.

  • PDF

The Value of Interleukin-12 as an Activity Marker of Pulmonary Sarcoidosis (폐유육종증의 활동성 지표로서 IL-12의 효용성에 관한 연구)

  • Kim, Tae-Hyung;Jeon, Yong-Gam;Shim, Tae-Sun;Lim, Chae-Man;Koh, Yun-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Won-Dong;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.215-228
    • /
    • 1999
  • Background: Sarcoidosis is a chronic granulomatous inflammatory disease of unknown etiology often involving the lungs and intrathoracic lymph nodes. The natural course of sarcoidosis is variable from spontaneous remission to significant morbidity or death. But, the mechanisms causing the variable clinical outcomes or any single parameter to predict the prognosis was not known. In sarcoidosis, the number and the activity of CD4 + lymphocytes are significantly increased at the loci of disease and their oligoclonality suggests that the CD4 + lymphocytes hyperreactivity may be caused by persistent antigenic stimulus. Recently, it has been known that CD4+ lymphocytes can be subdivided into 2 distinct population(Th1 and Th2) defined by the spectrum of cytokines produced by these cells. Th1 cells promote cellular immunity associated with delayed type hypersensitivity reactions by generating IL-2 and IFN-$\gamma$. Th2 cells playa role in allergic responses and immediate hypersensitivity reactions by secreting IL-4, IL-5, and IL-10. CD4+ lymphocytes in pulmonary sarcoidosis were reported to be mainly Th1 cells. IL-12 has been known to play an important role in differentiation of undifferentiated naive T cells to Th1 cells. And, Moller et al. observed increased IL-12 in bronchoalveolar lavage fluid(BALF) in patients with sarcoidosis. So it is possible that the elevated level of IL-12 is necessary for the continuous progression of the disease in active sarcoidosis. This study was performed to test the assumption that IL-12 can be a marker of active pulmonary sarcoidosis. Methods: We measured the concentration of IL-12 in BALF and in conditioned medium of alveolar macrophage(AM) using ELISA(enzyme-linked immunosorbent assay) method in 26 patients with pulmonary sarcoidosis(10 males, 16 females, mean age: $39.8{\pm}2.1$ years) and 11 normal control. Clinically, 14 patients had active sarcoidosis and 12 patients had inactive. Results: Total cells counts, percentage and number of lymhocytes, number of AM and CD4/CD8 lymphocyte ratio in BALF were significantly higher in patients with sarcoidosis than in control group. But none of these parameters could differentiate active sarcoidosis from inactive disease. The concentration of IL-12 in BALF was significantly increased in sarcoidosis patients ($49.3{\pm}9.2$ pg/ml) than in normal control ($2.5{\pm}0.4$ pg/ml) (p<0.001). Moreover it was significantly higher in patients with active sarcoidosis ($70.3{\pm}14.8$ pg/ml) than in inactive disease ($24.8{\pm}3.l$ pg/ml) (p=0.001). Also, the concentration of IL-12 in BALF showed significant correlation with the percentage of AM(p<0.001), percentage(p<0.001) and number of lymphocyte(p<0.001) in BALF, suggesting the close relationship between the level of IL-12 in BALF and the inflammatory cell infiltration in the lungs. Furthermore, we found a significant correlation between the level of IL-12 and the concentration of soluble ICAM-1 : in serum(p<0.001) and BALF (p=0.001), and also between IL-12 level and ICAM-1 expression of AM(p<0.001). The AM from patients with pulmonary sarcoidosis secreted significantly larger amount of IL-12 ($206.2{\pm}61.9$ pg/ml) than those of control ($68.3{\pm}43.7$ pg/ml) (p<0.008), but, there was no difference between inactive and active disease group. Conclusion : Our data suggest that the BALF IL-12 level can be used as a marker of the activity of pulmonary sarcoidosis.

  • PDF