• Title/Summary/Keyword: unit water test

Search Result 396, Processing Time 0.028 seconds

Effect of Modified Ultrafiltration on the Postoperative State after Pediatric Open Heart Surgery. (소아 개심술에 있어서 변형 초여과법(Modified Ultrafiltration)이 술후 상태에 미치는 영향)

  • 방종경;천종록;김규태
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.456-465
    • /
    • 1998
  • Cardiopulmonary bypass(CPB) in children is associated with the accumulation of body water after cardiac operation, as a consequence of an inflammatory capillary leak. Following work by Elliott in 1991, modified ultrafiltration(MUF) was introduced after bypass as a means of hemoconcentrating patients and a potential way of removing water from the tissues. We have carried out a prospective randomized study of 20 children undergoing open heart surgery, comparing MUF with nonfiltered controls. MUF was carried out for a mean of 18.9 minutes after completion of CPB to a hematocrit of 37.1%(mean). The mean water volulme removed by the ultrafiltration was 38.4 ml/kg and the mean blood volume retransfused from the oxygenator during the ultrafiltration was 32.1 ml/kg. Fluid balance, hemodynamics, hematocrit, osmolarity and dosage of drug treatment were recorded for 4∼12 hours postoperatively. The results were analyzed using Student t-test and ANOVA, comparing controls(n=10) to MUF(n=10). Blood loss(ml/kg/24hr) was 14.5(mean) in MUF versus 13.7 in controls; blood transfused(ml/kg/24hr) 6.6 in MUF versus 15.2 in controls; plasma transfused(ml/kg/24hr) 65.7 in MUF versus 59.6 in controls. There was rise in arterial blood pressure and hematocrit during MUF. Percent rise of systolic blood pressure was 28.8% in MUF versus 18.7% in controls(p=0.366); percent rise of diastolic blood pressure was 28.8% in MUF versus 8.5% in controls(p=0.135); and percent rise of mean blood pressure was 36.2% in MUF versus 8.2% in controls (p=0.086). Percent rise of hematocrit was 40.0% in MUF versus 23.5% in controls(p=0.002). There was no significant difference in the inotropic requirement and the postoperative serum osmolarity between two groups. The number of days on the ventilator, the duration of stay in the intensive care unit, and the postoperative hospital stay were not significantly different between the two groups.

  • PDF

An Analysis of the Practices of Dental Hygienists in Offering Oral Health Education -In Case of Adult Patients Visiting Dental Clinics- (치과위생사의 구강보건지도 실천분석 -진료실내의 성인환자를 중심으로-)

  • Lee, Sung-Sook;Cho, Myung-Sook;Kim, Seol-Ag
    • Journal of the Korean Society of School Health
    • /
    • v.12 no.1
    • /
    • pp.131-141
    • /
    • 1999
  • The purpose of this study was to serve as a basis for the planning of oral health education and the development of an oral health-promotion program for patients who visited dental clinics by examining how much dental hygienists offered oral health education to adult patients at dental clinics. A parent group was selected, being made up of 1,600 dental hygienists who registered with the Dental Hygienist Association and worked in Seoul. The questionnaire survey was carried out and an ${\chi}^2-test$ was made using the data collected from 218 subjects to determine how their practice of oral health education was different according to certain general characteristics(the sort of organization for which they worked, age, the term of their service, and the mean number of patients per day). As a result, the following findings were obtained: 1. Thees general characteristics made the following differences to the content of oral health, education: The sort of organization for which the subjects worked made a significant difference in the following tooth brushing instruction (p<0.05), the effect of oral prophylaxis or education about aftereffects (p<0.05), the regular examination of prosthesis (p<0.05), smoking-prohibition education (p<0.05), and the prevention poor-quality fillings (p<0.01). The mean number of patients per day made significant differences to the regular examination of prosthesis (p<0.05) and the prevention poor-quality fillings (p<0.01). But no significant disparity was generated by age or the term of service. 2. The general characteristics made the following differences to education about nutrition and diet counseling: The sort of organization for which the subjects worked had a significant effect just on the importance of a balanced menu (p<0.05). Age made significant differences in advice for vitamin, mineral, protein or other nutrients (p<0.01), and the importance of balanced menu (p<0.001). The term of service made significant differences in the importance of balanced menu (p<0.01), and advice for nutrients including vitamin, mineral or protein (p<0.01). 3. The general characteristics made the following differences to the recommendation and use of oral hygiene aids: The sort of oragnization for which they worked made significant differences only to a gingival massager and water pick (p<0.05). No significant difference was produced by age, the term of service or the mean number of patients per day. 4. The use of educational media for oral health was different according to the general characteristics: The use of pamphlets or booklets significantly varied depending on the organization for which they worked and with the mean number of patients per day (p<0.05). The use of slides or slide projectors was significantly affected by age (p<0.05). But no significant disparity was yielded by the term of service. 5. The general characteristics made the following difference as to whether a continued oral management system was carried out or not: The sort of organization for which they worked had very a significant effect on this result (p<0.001), and no significant disparity was made by age, the term of service or the mean number of patients per day. 6. The place where oral health education was giver differed according to the following general characteristics: The sort of organization for which they worked made very a significant difference as to the use of an examination room's dental unit chair or waiting room (p<0.01), and to the use of an oral health education room or reception counter (p<0.001). The term of service had a significant effect on the use of a counseling room (p<0.01). And the mean number of patients per day made significant differences in the use of a dental unit chair or reception counter (p<0.05), and to the use of an oral health education room or waiting room (p<0.01).

  • PDF

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

Antithrombotic Activities of Cheongkookjang and Cheongkookjang Fermented with Green Tea or Mugwort (청국장 및 녹차, 쑥이 첨가된 청국장의 항혈전 활성)

  • Lee, Kyung-Ae;Jang, Jeong-Oak;Yoon, Hye-Kyung;Kim, Moo-Sung
    • Korean Journal of Microbiology
    • /
    • v.43 no.4
    • /
    • pp.298-303
    • /
    • 2007
  • Antithrombotic activities of water extract of cheongkookjang and cheongkookjang fermented with green tea or mugwort were evaluated on some antithrombosis related activities in vitro and thrombotic death inhibition in vivo. Cheongkookjang made of white soybean (Glycine max) or black small soybean (Rhynchosia nulubilis) showed potent antioxidative activities. Addition of green tea or mugwort during cheongkookjang fermentation increased the antioxidative activity, cheongkookjang with green tea showed more drastic increase compared with cheongkookjang with mugwort. Nitrite scavenging effects of the cheongkookjang extracts were prominent but the addition of green tea or mugwort seldom increased the scavenging effects. All the cheongkookjang extracts showed strong inhibitory activities on platelet aggregation. The inhibitory activities of cheongkookjang were increased considerably by addition of green tea or mugwort even with low concentration. Plasmin unit as fibrinolytic activity was not affected considerably by addition of green tea. Addition of mugwort decreased the activity transiently at low concentration ($0.3{\sim}1.0%$) but increased again slowly at higher concentration ($1{\sim}3%$). In vitro thrombotic death inhibition test, the antithrombotic activity of cheongkookjang made of black small bean with green tea was higher by about 1.5 times compared to that without green tea. As results, cheongkookjang might inhibit antithrombosis not only by fibrinolytic action but also by inhibition of platelet aggregation and antioxidative action. The addition of functional materials such as green tea or mugwort could increase the antithrombotic function, even at low concentration.

Bond strength of fiber reinforced composite after repair (섬유 강화 컴포지트의 수리 후 접합 강도)

  • Kim, Min-Jung;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.188-197
    • /
    • 2006
  • Fiber reinforced composite (FRC) is usually used as a connector joining a few teeth into one unit in orthodontics. However, fracture often occurs during the two to three years of the orthodontic treatment period due to repeated occlusal loading or water sorption in the oral environment. We simulated the repair by overlapping and attaching portions of two FRC strips in the middle and performed a three-point bending test to investigate the changes of the repair strength among the different FRC groups. The specimens were grouped according to the overlapping lengths of the two FRC strips, which were 1, 2, 3 and 4 mm (group E1, E2, E3 and E4, respectively) and the control group consisted of unrepaired, intact FRC strips. Each group consisted of 6 specimens and were cured with a light emitting diode curing unit. Group E4 showed the highest maximum loads of 2.67 N, then the control group (2.39 N), group E3 (2.35 N), E2 (2.10 N), and E1 (1.75 N) in decreasing order. Group E4 also showed the highest stiffness, which was 2.32 N/mm, however, the stiffness of group E3 (2.06N/mm) was higher than that of the control group (1.88 N/mm). According to the visual examination, the specimens tended to be bent rather than being fractured into two pieces with an increased length of overlapping portions. The above results suggest that a minimum overlapping length of 3 mm was necessary to obtain an adequate repair of a 10 mm length of FRC connector. In addition, the critical section adjacent to the joint area, where the thickness decreased abruptly, should be reinforced with flowable resin to minimize the bending tendency.

THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES (다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구)

  • Choi, Nam-Ki;Cho, Seong-Hoon;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • The objective of this study was to compare the shear bond strengths of five dentin adhesive systems cured with three different light curing sources. Seventy five noncarious permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), G-Bond (GB). And three light curing unit systems were used: Elipar Free light 2(LED), OptiLux 501 (Halogen), Flipo (PAC). For the shear bonding test, the labial and lingual surfaces of permanent teeth were used. To obtain a flat dentin surface, the labial and lingual surfaces of the teeth were sanded on SiO2 with number 600 grit and then divided into 15 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. When cured with Freelight 2, the shear bond strength of SM was significantly higher than that of PL, GB (p<0.05), whereas no significant difference was found among those of any other bonding agents. 2. When cured with Optilux 501, the shear bond strength of SM was significantly higher than those of any other bonding agents (p<0.05), whereas no singnificant difference was found among those of andy other bonding agents. 3. When cured with Flipo, the shear bond strength of SM was significantly higher than those of SB, SE, GB (p<0.05), whereas no significant differences was found among those of any other bonding agents. 4. For comparison according to three different light cure unit system, except SB and GB, each three dentin bonding agents showed no significant difference. For SB, only Freelight 2 was significantly higher than the others, with no significant difference between Optilux 501 and Flip. For GB, Statistically significant difference was found only between Freelight and Flipo.

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

Application of Chlorophyll Fluorescence Parameters for the Detection of Water Stress Ranges in Grafted Watermelon Seedlings (수박접목묘의 건조스트레스 범위 탐지를 위한 엽록소형광 지수의 적용)

  • Shin, Yu Kyeong;Kim, Yong Hyeon;Lee, Jun Gu
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.461-470
    • /
    • 2019
  • This study was carried out to quantify the drought stress in grafted watermelon seedlings non-destructively by using chlorophyll fluorescence (CF) imaging technique rather than the visual judgment. Six-day old watermelon seedlings were grown under uniform irrigation for 3 days, and then given drought stress. Afterward, the sensor for the measurement of water content in plug tray cell unit was used to classify the drought-stress level into nine groups from D1 (53.0%, sufficient moisture state) to D9 (15.7%, extremely dry stress), and the 16 CF parameters were measured. In addition, re-irrigation was performed on the drought stressed seedlings(D5 - D9) to determine the growth and photosynthesis recovery level, which was not confirmed by visual judgment. The kinetic curve patterns of CF in three different drought stressed seedling groups were found to be different for the early detection of drought stress. All the 16 CF parameters decreased continuously with exposure to drought stress and drastically decreased from D5 (32.1%) where the visual judgment was possible. The fluorescence decline ratio (Rfd_Lss) started to decrease from the initial drought stress level (D5 - D6), and the Maximum PSII quantum yield (Fv/Fm) was significantly decreased in the later extreme drought stress range (D7 - D9) by re-irrigation recovery test. Thus, Rfd_Lss and Fv/Fm parameters were finally selected as potent indicators of growth and photosynthesis recovery in the initial and later stages of drought stress. Also, to the differences in the numerical values of the individual chlorophyll fluorescence parameters, the drought stress level was intuitively confirmed through the image. These results indicate that Rfd and Fv/Fm can be considered as potential CF parameters for the detection of low and extremely high drought stress, respectively. Furthermore, Fv/Fm can be considered as the best CF parameters for recovery at re-irrigation.

Topographic Factors Computation in Island: A Comparison of Different Open Source GIS Programs (오픈소스 GIS 프로그램의 지형인자 계산 비교: 도서지역 경사도와 지형습윤지수 중심으로)

  • Lee, Bora;Lee, Ho-Sang;Lee, Gwang-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.903-916
    • /
    • 2021
  • An area's topography refers to the shape of the earth's surface, described by its elevation, slope, and aspect, among other features. The topographical conditions determine energy flowsthat move water and energy from higher to lower elevations, such as how much solar energy will be received and how much wind or rain will affect it. Another common factor, the topographic wetness index (TWI), is a calculation in digital elevation models of the tendency to accumulate water per slope and unit area, and is one of the most widely referenced hydrologic topographic factors, which helps explain the location of forest vegetation. Analyses of topographical factors can be calculated using a geographic information system (GIS) program based on digital elevation model (DEM) data. Recently, a large number of free open source software (FOSS) GIS programs are available and developed for researchers, industries, and governments. FOSS GIS programs provide opportunitiesfor flexible algorithms customized forspecific user needs. The majority of biodiversity in island areas exists at about 20% higher elevations than in land ecosystems, playing an important role in ecological processes and therefore of high ecological value. However, island areas are vulnerable to disturbances and damage, such as through climate change, environmental pollution, development, and human intervention, and lacks systematic investigation due to geographical limitations (e.g. remoteness; difficulty to access). More than 4,000 of Korea's islands are within a few hours of its coast, and 88% are uninhabited, with 52% of them forested. The forest ecosystems of islands have fewer encounters with human interaction than on land, and therefore most of the topographical conditions are formed naturally and affected more directly by weather conditions or the environment. Therefore, the analysis of forest topography in island areas can be done more precisely than on its land counterparts, and therefore has become a major focus of attention in Korea. This study is focused on calculating the performance of different topographical factors using FOSS GIS programs. The test area is the island forests in Korea's south and the DEM of the target area was processed with GRASS GIS and SAGA GIS. The final slopes and TWI maps were produced as comparisons of the differences between topographic factor calculations of each respective FOSS GIS program. Finally, the merits of each FOSS GIS program used to calculate the topographic factors is discussed.