• 제목/요약/키워드: unit water test

검색결과 396건 처리시간 0.026초

강제대류 열전달을 이용한 형상기억합금 작동기 (Forced Convection heated and cooled SMA(Shape Memory Alloy) Actuator)

  • 전형열;김정훈;박응식
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.100-103
    • /
    • 2005
  • This work discusses the numerical analysis, the design and experimental test of the SMA (Shape Memory Alloy) actuator along with its capabilities and limitations. Convection heating and cooling using water actuate the SMA element of the actuator. The fuel such as propane, having a high energy density, is used as the energy source for the SMA actuator in order to increase power and energy density of the system, and thus in order to obviate the need for electrical power supplies such as batteries. The system is composed of a pump, valves, bellows, a heater (burner), control unit and a displacement amplification device. The actuation frequency is compared with the prediction obtained from numerical analysis. For the designed SMA actuator system, the results of numerical analysis were utilized in determining design parameters and operating conditions.

  • PDF

위생캔으로 제조한 Bacillus Starter 발효대두의 품질 평가와 금속물질 함량에 관한 연구 (Studies on the Quality Evaluation and Metal Content of Sanitary Canned by Fermented Soybean of Bacillus starter)

  • 허윤행
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.14-20
    • /
    • 2002
  • In order to improve the quality and sensory evaluation of Fermented Soybean(Chungkugjang meju) were investigated. The samples were prepared and fermented by the inoculation of Bacillus strains (B. subtilis, number 1, B. natto, number 2) that the product made With sanitary canned food. 1. The water content of samples was 46.75~50.60%, pH 5.35~6.95 and total acidity 3.26~3.62. 2. The reducing sugar of content for sample was 9.49~10.05%, Amino-N, 67~396mg% and the activity of protease was 0.36~1.49unit/g. 3. The heavy metals analyzed from sample cans, iron, tin and lead content of sample were 5.32~5.84ppm, 27.31~29.04ppm and 0.019~0.021ppm. 4. Therefore, results that Chungkugjang-meju manufactured from B. natto starter induced better product Quality and sensory test than that of the B. subtilis strain.

Standardization and Method Selection for the Trenchless Repair Technology of Sewer using Cured-in-place Pipe

  • Kim, Taeeung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권2호
    • /
    • pp.70-78
    • /
    • 2022
  • The trenchless entire repair technology (TERT) have many different names depending on the companies, and they have the same or similar methods as well as materials. In addition, there was quiet difficulty in application of field working and even confuse to classify for new TERT, while application criteria of TERT is not listed systematically. This study proposed standardization and method for TERT affecting by pipe condition, working materials, working method, specification/quantity per unit according to field condition, strange affairs and others. Determination criteria of defective sewer pipe has proposed to effective method which modify a criteria between Ministry of Environment and Seoul Metropolitan City. A Cured-in-place pipe (CIPP) is suitable for TERT, and the design criteria for the entire broken pipe are proposed when the pipe itself deforms more than 10%. A check lists are specimen preparing, hardening site made by clamped mold, numbers, flexural and tensile property, water leak and desquamation test, and have to use material property of minimum CIPP value depend on ISO 11296-4, ISO 11297-4, KS M3550-7 and KS M3550-9.

The effect of jaw's curvature on Brazilian tensile strength of rocks

  • Yousefi, Halime;Fereidooni, Davood
    • Geomechanics and Engineering
    • /
    • 제23권2호
    • /
    • pp.165-178
    • /
    • 2020
  • This paper investigates the effect of the jaw's curvature, also known by contact angle and jaw arc central angle (2α), of the Brazilian test apparatus on indirect tensile strength of various rock types. That's why, ten rock samples including limestone, marble, skarn, granite, diorite, and granodiorite were collected from some quarries in different provinces of Iran. Petrographic, mineralogical and textural investigations were performed using thin section analyses. Physical properties of the selected rock samples namely dry and saturated unit weights, porosity, water absorption, and specific gravity were determined for the rock samples. In addition, Brazilian tensile strength at different 2α angles (i.e., 2α = 0°, 10°, 15°, 20°, 45°, and 60°) were determined for the rocks in the laboratory. Results show that the parameter for the rocks is between 3.81 MPa at 2α=0° and 54.76 MPa at 2α=60°. This means that Brazilian tensile strength increased with increasing 2α angle from 0° to 60°. Also, it was found that the highest change rate of the Brazilian tensile strength occurs in range of 2α=15°-30° for most studied rock samples. In some tested samples, the parameter is decreased only at 2α = 60°. The values of Brazilian tensile strength of the rocks tested by flat and standard jaws are near to each other.

Development of an Entrainment Model for the Steam Line Break Mass and Energy Release Analysis

  • Park, Young-Chan;Kim, Yoo
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.101-108
    • /
    • 2003
  • The purpose of this study is to develop an entrainment model of the Pressurized Water Reactor (PWR) U-tube Steam Generator (SG) for Main Steam Line Break (MSLB) analyses. Generally, the temperature of the inside containment vessel at MSLB is decreased by introducing the liquid entrainment effect. This effect makes a profit on the aspect of integrity evaluation for Equipment Environmental Qualification (EEQ) in the containment. However, the target plant, Kori unit 1 does not have the entrainment data. Therefore, this study has been performed. RETRAN-3D and LOFTRAN computer programs are used for the model development. There are several parameters that are used for the initial benchmark, such as Combustion Engineerings (CE) experimental data and the RETRAN-3D model which describes the test leg. A sensitivity study is then performed with this model in which the model parameters are varied until the calculated results provide reasonable agreement with the measured results for the entire test set. Finally, a multiplication factor has been obtained from the 95/95 values of the calculated (best-estimate) quality data relative to the measured quality data. With this new methodology, an additional temperature margin of about 40$^{\circ}C$ can be obtained. So, the new methodology is found to have an explicit advantage to EQ analyses.

강제 대류를 이용한 형상기억합금 작동기 (SMA(SHAPE MEMORY ALLOY) ACTUATOR USING FORCED CONVECTION)

  • 전형열;김정훈;박응식
    • 한국전산유체공학회지
    • /
    • 제10권2호
    • /
    • pp.48-53
    • /
    • 2005
  • This work discusses the numerical analysis, the design and experimental test of the SMA actuator along with its capabilities and limitations. Convective heating and cooling using water actuate the SMA(Shape memory alloy) element of the actuator. The fuel such as propane, having a high energy density, is used as the energy source for the SMA actuator in order to increase power and energy density of the system, and thus in order to obviate the need for electrical power supplies such as batteries. The system is composed of a pump, valves, bellows, a heater(burner), control unit and a displacement amplification device. The experimental test of the SMA actuator system results in 150 MPa stress(force : 1560 N) with $3\%$ strain and 0.5 Hz. actuation frequency. The actuation frequency is compared with the prediction obtained from numerical analysis. For the designed SMA actuator system, the results of numerical analysis were utilized in determining design parameters and operating conditions.

EVALUATION OF THE APPLICABLE REACTIVITY RANGE OF A REACTIVITY COMPUTER FOR A CANDU-6 REACTOR

  • Lee, Eun Ki;Park, Dong Hwan;Lee, Whan Soo
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.183-194
    • /
    • 2014
  • Recently, a CANDU digital reactivity computer system (CDRCS) to measure the worth of the liquid zone controller in a CANDU-6 was developed and successfully applied to a physics test of refurbished Wolsong Unit 1. In advance of using the CDRCS, its measureable reactivity range should be investigated and confirmed. There are two reasons for this investigation. First, the CANDU-6 has a larger reactor and smaller excore detectors than a general PWR and consequently the measured reactivity is likely to reflect the peripheral power variation only, not the whole core. The second reason is photo neutrons generated from the interaction of the moderator and gamma-rays, which are never considered in a PWR. To evaluate the limitations of the CDRCS, several tens of three-dimensional steady and transient simulations were performed. The simulated detector signals were used to obtain the dynamic reactivity. The difference between the dynamic reactivity and the static worth increases in line with the water level changes. The maximum allowable reactivity was determined to be 1.4 mk in the case of CANDU-6 by confining the difference to less than 1%.

지형기후모형에 근거한 서리경보시스템 구축 (Site - Specific Frost Warning Based on Topoclimatic Estimation of Daily Minimum Temperature)

  • 정유란;서희철;윤진일
    • 한국농림기상학회지
    • /
    • 제6권3호
    • /
    • pp.164-169
    • /
    • 2004
  • A spatial interpolation scheme incorporating local geographic potential for cold air accumulation (TOPSIM) was used to test the feasibility of operational frost warning in Chatancheon basin in Yeoncheon County, where the introduction of new crops including temperate zone fruits is planned. Air temperature from April to June 2003 was measured at one-minute intervals at four locations within the basin. Cold-air accumulation potentials (CAP) at 4 sites were calculated for 3 different catchment scales: a rectangular area of 65 x 55 km which covers the whole county, the KOWACO (Korea Water Corporation) hydrologic unit which includes all 4 sites, and the sub-basins delineated by a stream network analysis of the digital elevation model. Daily minimum temperatures at 4 sites were calculated by interpolating the perfect prognosis (i.e., synoptic observations at KMA Dongducheon station) based on TOPSIM with 3 different CAPs. Mean error, mean absolute error, and root mean square error were calculated for 45 days with no precipitation to test the model performance. For the 3 flat locations, little difference was detected in model performance among 3 catchment areas, but the best performance was found with the CAPs calculated for sub-basins at one site (Oksan) on complex terrain. When TOPSIM loaded with sub-basin CAPs was applied to Oksan to predict frost events during the fruit flowering period in 2004, the goodness of fit was sufficient for making an operational frost warning system for mountainous areas.

Run related probability function and their application to start-up demonstration tests

  • Bi, Yi-Ming;Oh, Jung-Taek;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • 제27권4호
    • /
    • pp.1067-1074
    • /
    • 2016
  • A start-up demonstration test is a mechanism that is usually used to determine the reliability of equipment, for example water pumps, car batteries and power generators. The simplest and oldest start-up demonstration tests are called CS (consecutive successes) which have been studied by Hahn and Gage (1983), Viveros and Balakrishnan (1993).At first Hahn and Gage (1983) discussed the start-up demonstration test. I was based on i.i.d (independently and identically distributed) binary outcomes with the specified number of consecutive successful start-ups. Oh (2016) studied CSNCF (consecutive successful, but not consecutive failures). In this paper, we investigated the CS and CSNCF models, also their applications to start-up demonstration tests. The numerical results showed that the expectations and variances of the total number of attempted start-ups until the acceptance of the unit are gradually increasing in all of the specified number of successes as the p (probability of a successful start-up in an single trial) decreases from 0.99 to 0.90. The difference between means of the CS mode and CSNCF model is small, but variances of the CS and CSNCF are big.

Impact of gamma radiation on 8051 microcontroller performance

  • Charu Sharma;Puspalata Rajesh;R.P. Behera;S. Amirthapandian
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4422-4430
    • /
    • 2022
  • Studying the effects of gamma radiation on the instrumentation and control (I&C) system of a nuclear power plant is critical to the successful and reliable operation of the plant. In the accidental scenario, the adverse environment of ionizing radiation affects the performance of the I&C system and it leads to inaccurate and incomprehensible results. This paper reports the effects of gamma radiation on the AT89C51RD2, a commercial-off-the-shelf 8-bit high-performance flash microcontroller. The microcontroller, selected for the device under test for this study is used in the remote terminal unit for a nuclear power plant. The custom circuits were made to test the microcontroller under different gamma doses using a 60Co gamma source in both ex-situ and in-situ modes. The device was exposed to a maximum dose of 1.5 kGy. Under this hostile environment, the performance of the microcontroller was studied in terms of device current and voltage changes. It was observed that the microcontroller device can operate up to a total absorbed dose of approximately 0.6 kGy without any failure or degradation in its performance.