• 제목/요약/키워드: unit load system

검색결과 741건 처리시간 0.025초

전력선 통신을 이용한 원격부하관리시스템 개발 (Development of Remote Load Management System Using PowerLine Communication)

  • 나채동;이성범;정을기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.149-152
    • /
    • 2002
  • In this paper, an simple load management system was introduced. This system is composed of Main Controller, DTU(Dispersion Terminal Unit), Power Line Modem and HMI (Human Machine Interface) program. To control distant loads, network function using powerline communication is implemented in DTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved in a several experiments.

  • PDF

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

Overload Detection and Control for Switching Systems using Fuzzy Rules

  • Rhee, Chung-Hoon;Rhee, Byung-Ho;Cho, Sung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • 제17권4E호
    • /
    • pp.28-34
    • /
    • 1998
  • In most switching system, the processing unit is designed to work efficiently even at relatively high loads, but when the offered traffic exceeds a particular level, the rate of completed calls can fall drastically. A single call handled by the switching system consists of a sequence of events or messages that has to be processed by the control unit. The control unit is not only incapable of handling all of the offered calls, but also its call handling capability can drop as the offered load increases. The real time available for call processing is a critical resource that requires careful management. Therefore, the overloading of this resource must be detected by a subscriber in the from of a dial tone delay or an uncompleted call which is either blocked or mishandled. The subscriber may respond by either dialing prematurely or by re-attempting a call. This action can further escalate the processors load, which is spent for uncompleted calls. Unless a proper control is used, the switching system can finally break down. In this paper, we paper, we propose a fuzzy overload detection and control method for switching systems, which can by generating fuzzy rules via fuzzy aggregation networks. Simulation results involving a switching system is given.

  • PDF

농촌유역의 오염부하량산정을 위한 범용적 GIS 및 데이터베이스의 구축 (Development of Odinary GIS and Database for Calculation of Pollutant Load in Rural Areas)

  • 양영민;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.460-465
    • /
    • 2001
  • Pollutant load using unit load method is calculated by simply equation, especially, very useful in the area that didn't exist about water quality data. However, it takes long time to calculate pollutant load with area in which there is various pollutants and if the boundary of a basin altered, the work of calculation about pollutant load must be begun from the first again. Therefore, a Total Daily Load Program(TDLP) was developed to calculate pollutant load automatically in rural area. The TDLP includes a geographic information system(GIS), relational database system(RDBS), User Interface. This Program can provide user with creating a boundary of the basin that user is concerned with to satisfy the water quality regulations and calculating daily load for various pollutants. The effort was conducted to apply the developed TDLP to calculating pollutant load in rural basin called Bok-ha river.

  • PDF

Ralu-Pack 250YC를 충전한 충전탑에서 암모니아가스 제거에 관한 연구 (A study on Removal of $NH_3$ Gas in a Towar using a Ralu-Pack 250YC as a Packing Material)

  • 김석택
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.389-392
    • /
    • 2000
  • In this study a packed tower was selected for the treatment apparatus of $NH_3$ gas produced in industry. Formerly latticework packing has been used in preventive facility of treatment of $NH_3$ gas. However recently metallic Ralu-Pack 250YC. structured packing is usually being used in petrochemical production plant. This study is for the application the packing to the $NH_3$ gas treatment in wet scrubbing process. In Air/water system hydraulic pressure drop dependent of specific liquid load and gas capacity factor was continuous and parallel from graph. The tower height can be determuined by the number of transfer unit and the height of transfer unit influenced on liquid distribution.

  • PDF

기동정지계획을 고려한 직접부하제어에 관한 연구 (Research of Direct Load Control Considering Unit Commitment)

  • 이범;김용하;김형중;문혁기;정현성;이영길;최상규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.220-222
    • /
    • 2001
  • This paper describes the optimizing method of direct load control (DLC) considering unit commitment which is based on dynamic programming. To consider the unit commitment on DLC, 3-Dimensional dynamic programming as a new unit commitment method is developed. And, this method is applied to DLC. As a result, optimization of operating schedule with DLC is possible. This method is applied to the test system, and usefulness of the method is verified.

  • PDF

자동차 배터리 지지 구조의 진동 피로 해석에 대한 연구 (Study on Vibration Fatigue Analysis of Automotive Battery Supporter)

  • 안상호
    • 자동차안전학회지
    • /
    • 제11권4호
    • /
    • pp.22-27
    • /
    • 2019
  • In this paper, the vibration load and analysis results for automotive battery supporter were performed to provide efficient vibration tolerance performance prediction methods for single-product vibration tolerance testing, and the major influencing factors and considerations for setting up single-unit vibration tolerance tests were reviewed. A common applicable standard load was applied to efficiently predict the performance of single-unit vibrations through the frequency response analysis technique. The results similar to test results can be predicted by checking vulnerable parts of the vehicle components for vibration loads and applying scale factor to standard loads. In addition, it was confirmed that the test conditions with a frequency generating the same durability severity as the endurance test are needed for accurate prediction of the durability of the single-unit vibration tolerance test conditions, and the acceleration and frequency with the conditions that there is no significant nonlinear phenomena in the vibration system are established during the single-unit vibration tolerance test conditions.

산업용 로봇을 위한 직류 서보전동기 제어시스템 (Brushed Servo-Motor Control System for Industrial Robot)

  • Sun-Hag Hong
    • 한국컴퓨터산업학회논문지
    • /
    • 제3권2호
    • /
    • pp.141-148
    • /
    • 2002
  • 본 논문에서는 고출력 산업용 로봇을 위한 직류 서보 전동기 제어시스템을 컴퓨터 GUI 환경[11,12]에서 제어 알고리즘을 적용하면서 실험할 수 있는 제어시스템 을 구현하였다. 직류 전동기 정격은 400용량, 1000ppr 광학식 엔코더 및 전자식 브레이크를 부하 변화량으로 채택하였다. 특히, 서보 구동부는 MOSFET 9540 및 540 FET를 사용하여 풀-브리지 방식으로 구동하였다. 서보 제어부는 8비트 PIC16C74 마이크로프로세서, RS-232 통신 포트 및 URD 전류 센서를 채택하였다. PID 방식을 기본으로 부하 변화량에 따는 다양한 계수 설정을 변화시키면서 제어 알고리즘을 적용하였다.

  • PDF

Use of High-performance Graphics Processing Units for Power System Demand Forecasting

  • He, Ting;Meng, Ke;Dong, Zhao-Yang;Oh, Yong-Taek;Xu, Yan
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.363-370
    • /
    • 2010
  • Load forecasting has always been essential to the operation and planning of power systems in deregulated electricity markets. Various methods have been proposed for load forecasting, and the neural network is one of the most widely accepted and used techniques. However, to obtain more accurate results, more information is needed as input variables, resulting in huge computational costs in the learning process. In this paper, to reduce training time in multi-layer perceptron-based short-term load forecasting, a graphics processing unit (GPU)-based computing method is introduced. The proposed approach is tested using the Korea electricity market historical demand data set. Results show that GPU-based computing greatly reduces computational costs.

항공관제용 정전류조정(CCR) 인버터 시스템의 개발 (A Constant Current Regulated Inverter System for Lighting and Beaconing of Aerodromes)

  • 손진근;박종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.141-146
    • /
    • 2006
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for Lighting and Beaconing of Aerodromes. The effectiveness of the proposed system confirmed through experimental results of CCR.

  • PDF