• Title/Summary/Keyword: unit generation rate

Search Result 116, Processing Time 0.024 seconds

Fast Prediction Unit Decision Using Quantized Transform Coefficient (양자화된 트랜스폼 계수를 이용한 고속 Prediction Unit 결정방법)

  • Gweon, Ryeong-Hee;Lee, Yung-Lyul
    • Journal of Broadcast Engineering
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2012
  • MPEG and VCEG have constituted a collaboration team called JCT-VC(Joint Collaborative Team on Video Coding) and have been developing the HEVC(High Efficiency Video Coding) standard. The next generation video coding standard HEVC shows higher compression rate compared with the H.264/AVC standard, but the encoder computational complexity of the HEVC encoder is significantly high. In order to reduce this computational complexity in the HEVC encoder, a fast prediction unit decision is proposed. The proposed fast prediction unit decision method reduces the encoder complexity by skipping the remaining prediction units if the current prediction unit does not have any non-zero quantized transform coefficient. The proposed method reduces the encoder computational complexity by 50.3% comparing with HM6.0 but it maintains the same level of coding efficiency.

Prevention of Invasive Candida Infections in the Neonatal Intensive Care Unit (신생아 집중치료실에서 침습 칸디다 감염의 예방)

  • Kim, Chun Soo
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • Invasive Candida infections (ICI) have become the third most common cause of late-onset infection among premature infants in the neonatal intensive care unit (NICU). Risk factors include birth weight less than 1,000 g, exposure to more than two antimicrobials, third generation cephalosporin exposure, parenteral nutrition including lipid emulsion, central venous catheter, and abdominal surgery. Candida colonization of the skin and gastrointestinal tract is an important first step in the pathogenesis of invasive disease. Strict infection control measures against the infection should be done in the NICU. The following practices are likely to contribute to reducing the rate of ICI: (1) restriction of broad-spectrum antibiotics, antacids and steroid; (2) introduction of early feeding and promoting breast milk. Fluconazole prophylaxis may be an effective control measure to prevent Candida colonization and infections in individual units with high incidence of fungal infection. In addition, there is a need of further data including the development of resistant strains and the effect on long-term neurodevelopmental outcomes of infants exposed to drugs before the initiation of routine application of antifungal prophylaxis in the NICU.

Generation of Food Waste from Different Sources and Its Composting Measures at the Apartment Complex (배출원별 음식물 쓰레기 발생 특성 및 아파트 단지에서의 퇴비화 방안 (대전 및 충청남도 지역을 중심으로))

  • Kang, H.;Lee, O.L.;Kim, J.W.;Hur, H.W.;Han, S.H.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.1
    • /
    • pp.53-66
    • /
    • 1998
  • This study was carried out to investigate the typical composition of food waste from municipal solid wastes (MSW) and unit food waste generation rates from different sources in the model cities and to study the food waste management system from unit household to composting facilities. The annual average food waste composition of MSW was determined as 49% in Taejon and 52% in Chungnam Province, respectively. No big difference in food waste composition was found among the different sources. Since the paper waste generally occupied the half of food waste, over 75% of MSW was found to be compostable or biodegradable. Per capita food waste generation rate, 200~250g/capita day was determined by the direct measurement from 32 households, while 380g/capita day for Chungnam Province and 400 g/capita day for Taejon were estimated by the load count analysis In the sanitary landfills. This difference means people contribute generating food waste at outside house approximately twice as much as that at inside house. Per capita food waste generation rates from several sources were determined as follows; 166~215g/capita day at municipalities, 400g/visitor day at a first class hotel, 170g/student day at a university restaurant. Food waste generation from restaurant was strongly dependant upon it's level or quality; 670g/capita day at the high level restaurant, 190g/capita day at the middle class and 60 g/capita day at the lower class restaurant. The food waste reduction rate in a In situ fermentor showed 30~40g/kg day.

  • PDF

Parametric Design of Axial Fan for Air-Conditioning Unit in terms of Aerodynamic Performance and Noise Level (공조용 축류홴 설계 및 설계변수에 따른 성능과 소음비교)

  • Lee, Seung-Jin;Choi, Go-Bong;Cho, Hong-Jun;Song, Woo-Seog;Lee, Seung-Bae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.3
    • /
    • pp.24-29
    • /
    • 2010
  • Axial fans for an air-conditioning unit are designed to equip the system with an expected flow-rate and low noise level by applying the blade design method of multi-sectioning and local camber generation. In this study, the distributions of chord length, stagger angle, and camber angle are globally and locally determined for the given specific speed, which is considered to be relatively high. The mock-up fans are observed to satisfy the aerodynamic performance and the noise level for the system simultaneously and discussed in terms of local flow patterns related to the emitted noise.

Performance Characteristics of a Pin-to-Cylinder Superposed Discharge Type Ozonizer (SDO)

  • Md. Fayzur Rahman;Lee, Kwang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.113-119
    • /
    • 2001
  • This paper presents a model for a pin-to-cylinder discharge type ozonizer, which utilizes the superposition of surface discharge and corona discharge operation. By changing the gas flow rate, the discharge power and the number of SDO units, the characteristics of ozone concentration ( $O_{3con}$), ozone generation ( $O_{3g}$) and ozone yield ( $O_{3Y}$) were investigated. Using one SDO unit the maximum values of $O_{3con}$, $O_{3g}$ and $O_{3Y}$ were found as 8100[ppm], 1623[mg/h] and 213[g/kWh] respectively. With two SDO units the corresponding values were found as 12800[ppm], 2893[mg/h] and 248[g/kWh] respectively. Hence using two SDO units the efficiency was improved by 16[%].y 16[%].

  • PDF

CCD Pixel Correction Table Generation for MSC

  • Kim Young Sun;Kong Jong-Pil;Heo Haeng-Pal;Park Jong-Euk;Paik Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.471-474
    • /
    • 2004
  • Not all CCD pixels generate uniform value for the uniform radiance due to the different process of manufacture and each pixel characteristics. And the image data compression is essential in the real time image transmission because of the high line rate and the limited RF bandwidth. This pixel's nonuniformity and the loss compression make CCD pixel correction necessary in on-orbit condition. In the MSC system, the NUC unit, which is a part of MSC PMU, is charge of the correction for CCD each pixel. The correction is performed with the gain and the offset table for the each pixel and the each TDI mode. These correction tables are generated and programmed in the PMU Flash memory through the various image data tests at the ground test. Besides, they can be uploaded from ground station after onorbit calibration. This paper describes the principle of the table generation and the test way of the non-uniformity after NUC

  • PDF

Thermodynamic Analysis of Power Generation Cycle Utilizing LNG Cold Energy (LNG 냉열을 이용하는 동력사이클 열역학 해석)

  • 최권일;장홍일
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.1
    • /
    • pp.48-55
    • /
    • 1999
  • thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). The power cycle used the air or water at room temperature as a heat source and the LNG at cryogenic temperature as a heat sink. Among manypossible configurations of the cycle. the open Rankine cycle. and the closed Brayton cycle, and the closed Rankine cycle are selected for the basic analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters such as the pressure ratio. the mass flow rate. the adiabatic efficiency. the heat exchanger effectiveness. or the working fluid. The optimal conditions for the parameters are presented to maximize the power output and the design considerations are discussed. It is concluded that the open Rankine cycle is the most recormmendable both in thermodynamic efficency and in practice.

  • PDF

Evaluation of Ramping Capability for Day-ahead Unit Commitment considering Wind Power Variability (풍력발전의 변동성을 고려한 기동정지계획에서의 적정 Ramping 용량 산정)

  • Lyu, Jae-Kun;Heo, Jae-Haeng;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.457-466
    • /
    • 2013
  • Wind energy is rapidly becoming significant generating technologies in electricity markets. As probabilistic nature of wind energy creates many uncertainties in the short-term scheduling, additional actions for reliable market operation should be taken. This paper presents a novel approach to evaluate ramping capability requirement for changes in imbalance energy between day-ahead market and real-time market due to uncertainty of wind generation as well as system load. Dynamic ramp rate model has been applied for realistic solution in unit commitment problem, which is implemented in day-ahead market. Probabilistic optimal power flow has been used to verify ramping capability determined by the proposed method is reasonable in economic and reliable aspects. This approach was tested on six-bus system and IEEE 118-bus system with a wind farm. The results show that the proposed approach provides ramping capability information to meet both forecasted variability and desired confidence level of anticipated uncertainty.

Low Power SAR ADC with Series Capacitor DAC (직렬 커패시터 D/A 변환기를 갖는 저전력 축차 비교형 A/D 변환기)

  • Lee, Jeong-Hyeon;Jin, Yu-Rin;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.90-97
    • /
    • 2019
  • The charge redistribution digital-to-analog converter(CR-DAC) is often used for successive approximation register analog-to-digital converter(SAR ADC) that requiring low power consumption and small circuit area. However, CR-DAC is required 2 to the power of N unit capacitors to generate reference voltage for successive approximation of the N-bit SAR ADC, and many unit capacitors occupy large circuit area and consume more power. In order to improve this problem, this paper proposes SAR ADC using series capacitor DAC. The series capacitor DAC is required 2(1+N) unit capacitors to generate reference voltage for successive approximation and charges only two capacitors of the reference generation block. Because of these structural characteristics, the SAR ADC using series capacitor DAC can reduce the power consumption and circuit area. Proposed SAR ADC was designed in CMOS 180nm process, and at 1.8V supply voltage and 500kS/s sampling rate, proposed 6-bit SAR ADC have signal-to-noise and distortion ratio(SNDR) of 36.49dB, effective number of bits(ENOB) of 5.77-bit, power consumption of 294uW.

The Development of the Waste Pneumatic Transportation System (진공식(眞空式) 쓰레기 파이프라인수송(輸送) System 개발(開發))

  • Park, Chung-Hyun;Kim, Bong-Geun;Kwon, Bong-kee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.3
    • /
    • pp.115-132
    • /
    • 1996
  • The present problems concerning the control of generation, storage, collection, transfer and transport, processing and disposal of the municipal waste are serious. And the transportation of the municipal waste is recently a important part of solid waste treatment and disposal. The waste pneumatic transportation system is expected to be an effective method for use in solving that problems. In this study, pneumatic transportation system was applied to 2,000-5,000 households of public/group housing for economic and technical analysis on the basis of data for working and operation. The proper equipment must be selected through economic and technical analysis for generation and properties of waste because the equipment in facilities of system is various. And the efficient operation method should be studied on the basis of information on the record of oeration. As the wet food waste clogs the pipeline, it is necessary to examine under the actual condition. The maximum unit waste generation rate based on the assumption that each household is comprised of 3.20 people is determined $2,340g/household{\cdot}day$, and it is included the 50% increase of seasonal and daily change.

  • PDF