• 제목/요약/키워드: unit generation rate

검색결과 117건 처리시간 0.028초

복합발전기 조합별 증분비 곡선 재설정에 관한 연구 (A Study on the Resetting of Incremental Heat Rate Curve of Combined Cycle Unit by Combination)

  • 홍상범;최준호
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.8-12
    • /
    • 2019
  • Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all(N:1) combinations of CC.

Cation exchange membrane and anion exchange membrane aided electrolysis processes for hypochlorite generation

  • Seong K. Kim;Dong-Min Shin;Ji Won Rhim
    • Membrane and Water Treatment
    • /
    • 제14권2호
    • /
    • pp.55-63
    • /
    • 2023
  • In this study, the influence of different IEMs (ion exchange membranes) to performance of the hypochlorite electrolysis unit with Cl2 recovery stream was investigated. More specifically, Nafion 117-a representative cation exchange membrane (CEM)-and aminated polypheylene oxide (APPO)-an anion exchange membrane (AEM)-were installed in the hypochlorite electrolysis unit, and the performance and the energy efficiency of the units were evaluated and compared. Regardless of whether CEM (Nafion 117) or AEM (APPO) was installed, the rate of hypochlorite generation was increased (by up to 24.3% and 22.2% for Nafion 117 and APPO, respectively) compared with the unit without an IEM. On the other hand, the power efficiency and the optimum operation condition of hypochlorite production units seem to depend on the conductivity and stability of the installed IEM. As the result, between Nafion 117 and APPO, higher performance and efficiency were achieved with Nafion 117, due to excellent conductivity and stability of the membrane.

순천시의 생활폐기물 발생량 예측 및 재활용시설의 용량산정에 관한 연구 (A study on the physico-chemical characteristics of municipal solid wastes generated in the sunchon city)

  • 허관;문옥란;왕승호
    • 유기물자원화
    • /
    • 제9권4호
    • /
    • pp.125-134
    • /
    • 2001
  • 순천시 생활계폐기물의 배출특성을 제시하고 장래 폐기물대책을 수립하는 기본적인 자료로 정보를 제공하고자 폐기물별 자원화시설의 용량을 산정하고 재활용시설의 운영관리 및 제반폐기물정책 수립에 활용하도록 하기 위해서 조사분석하여 다음과 같은 결과를 얻었다. 일반주택의 배출량원단위는 0.50kg/인${\cdot}$일로 배출량은 41.9톤/일, 공동주택의 배출량원단위는 0.45kg/인${\cdot}$일로 배출량은 55.5톤/일, 읍 면지역의 배출량원단위는 0.22kg/인${\cdot}$일로 배출량은 13.5톤/일로 나타나 주택지역의 생활계폐기물 배출량은 110.9톤/일이다. 재래시장의 배출량원단위는 1.85kg/상가 일로 배출량은 5,400kg/일이며, 소규모점포의 배출량원단위는 2.03kg/상가 일로 배출량은 25,101kg/일로 나타나 상가지역의 생활계폐기물 배출량은 30,501kg/일이다. 공장지역에서 배출되는 사업장생활계폐기물은 1일 평균 8.3톤, 학교와 병원 및 업무지역에서 배출되는 생활계폐기물의 1일 평균배출량은 각각 7.2kg과 3.0kg 및 6.6kg이다. 생활폐기물 중에서 음식물쓰레기는 평균 63.4톤/일 배출되었으며, 소각대상 가연성폐기물은 126.9톤/일 배출되었다. 음식물쓰레기처리시설의 내구년도를 약 5년(2006년도)으로 계획하면 처리대상량은 1일 42.4톤이 예상되며, 저부하 운전이나 고장보수로 인한 가동중지 등의 문제를 고려하여 처리능력을 25톤/일${\times}$2계열로 설치하는 것이 효율적일 것으로 판단된다. 소각처리시설의 내구년도를 약 10년(2011년도)으로 계획하면 처리대상량은 1일 150톤/일이 예상되며, 저부하 운전이나 고장보수로 인한 소각작업 중지 등의 문제를 고려하여 처리능력을 80톤/일${\times}$2계열로 설치하는 것이 효율적일 것으로 판단된다.

  • PDF

AGC 운용에 있어서의 원격 On-line 최대 증감발율 취득 기법 (Remote On-line Determination of the Load Rate Limit of Generation in AGC)

  • 권순만;전동훈;문원용;김석주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.119-121
    • /
    • 2000
  • The possibility of a remote on-line determination of the maximum load rates that are basically set at generation plants is investigated in automatic generation control (AGC) system. Energy management system (EMS) generates a test input to a remote power plant to get the samples of the generator output. Then from the samples it can be attempted to determine an approximate value of the load rate limit set by the operator. It is shown in computer simulation that in actual power plants the limit can be approximately determined from the input-output characteristics of the plants for a unit-step input.

  • PDF

Implementation of Chaotic UWB Systems for Low Rate WPAN

  • Lee, Cheol-Hyo;Kim, Jae-Young;Kim, Young-Kkwan;Choi, Sun-Kyu;Jang, Ui-Gi
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.339-342
    • /
    • 2005
  • In order to support ultrawide-band signal generation for low rate WPAN, several types of signal generation mechanisms are suggested such as Chaos, Impluse, and Chirp signals by the activity of IEEE 802.15.4a. The communication system applied chaos theory may have ultrawide-band characteristics with spread spectrum and immunity from multipath effect. In order to use the advantage of chaotic signal generation, we introduce the system implementation of communication and networking systems with the chaos UWB signal. This system may be composed of mainly three parts in hardware architecture : RF transmission with chaotic signal generation, signal receiver using amplifiers and filters, and 8051 & FPGA unit. The most difficult part is to implement the chaotic signal generator and build transceiver with it. The implementation of the system is devidced into two parts i.e. RF blocks and digital blocks with amplifiers, filters, ADC, 8051 processor, and FPGA. In this paper, we introduce the system block diagram for chaotic communications. Mainly the RF block is important for the system to have good performance based on the chaotic signal generator. And the main control board functions for controlling RF blocks, processing Tx and Rx data, and networking in MAC layer.

  • PDF

The Design and Construction of a High Efficiency Satellite Electrical Power Supply System

  • Mousavi, Navid
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.666-674
    • /
    • 2016
  • In this paper, a high efficiency satellite electrical power supply system is proposed. The increased efficiency of the power supply system allows for downscaling of the solar array and battery weight, which are among the most important satellite design considerations. The satellite power supply system comprises two units, namely a generation unit and a storage unit. To increase the efficiency of the solar array, a maximum power point tracker (MPPT) is used in the power generation unit. In order to improve the MPPT performance, a novel algorithm is proposed on the basis of the hill climbing method. This method can track the main peak of the array power curve in satellites with long duration missions under unpredicted circumstances such as a part of the array being damaged or the presence of a shadow. A lithium-ion battery is utilized in the storage unit. An algorithm for calculating the optimal rate of battery charging is proposed where the battery is charged with the maximum possible efficiency considering the situation of the satellite. The proposed system is designed and manufactured. In addition, it is compared to the conventional power supply systems in similar satellites. Results show a 12% increase in the overall efficiency of the power supply system when compared to the conventional method.

한국어의 리듬에 관한 실험음성학적 연구 (An Experimental Phonetic Study of Rhythm in Standard Korean)

  • 이현복
    • 대한음성학회지:말소리
    • /
    • 제25_26호
    • /
    • pp.52-64
    • /
    • 1993
  • This paper aims to explore the rhythmic phenomena of standard Korean by an experimental phonetic method. A total of 16 informants taking part in this experiment were divided into four groups : old males(OM) and old females(OF) in their fifties and young males(YM) and young females(YF) in their twenties. The informants were asked to read speech data consisting of two rhythmic units, each of which began with a stressed syllable with a long wowel. Starting with the frame / 'ma:1 'ma:nta /, the first rhythmic unit was expanded up to five syllables in all while keeping the second rhythmic unit constant with a view to investigate the pattern of increase in the interstress time interval. The results of this study are as follows: 1. There is a considerable difference between yen and old generations with respect to the duration of interstress interval . The young generation tends to speak faster than the old generation. This observation is supported by difference in the interstress intervals as exhibited by OM(389.66), OF(473), YM(275.55), YF(285.83) in the test frame '말 많다' ['ma:1 'ma:nta]. 2. Young and old generations showed a different tendency in the increase rate of duration between mono-syllables and polysyllables. In other words, the rhythm of young generation shows the tendency of syllable-timed language whereas that of old generation clearly leans towards the stressed-timed language.

  • PDF

발전기 출력특성을 고려한 최적전원구성 연구 (A Study of Optimal Fuel-Mix Considering Power Generation Operation)

  • 정영범;김길신;박창호;윤용범
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.28-37
    • /
    • 2011
  • Though Korea has introduced CBP(Cost Based pool) power trading system since 2001, long-term Generation system planning has been executed by government for Cost minimization every 2 years. Until currently the model which is used for Generation system planning and best-mix only considers cost minimization and total yearly or quarterly electricity demand every year. In a view point of one day power supply operation, technical characteristics, like the ramp up/down rate of total generation system, minimum up/down time and GFRQ(Governor Free Response Quantity), are very important. this paper analyzes Optimal Fuel-Mix for 2022 Korea generation system satisfying these constraints of each fuel type and considering pump storage plants, construction cost and $CO_2$ emission charge Using MILP(Mixed Integer Linear Programming) method. Also the sensitivity analysis which follows in future power industry environmental change accomplished.

중첩방전 반응기에 의한 오존의 생성 (Ozone Generation by Superimposing Discharge Reactor)

  • 우인성;황명환;조정국;이영희;목연수
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.63-68
    • /
    • 1999
  • In this paper, characteristics of ozone generation by using coil and SPCP + DC corona reactor was studied. The ceramic-based surface discharge electrode, which was first invented as a high-efficiency ozonizer, has been used as an experimental plasma chemical reactor.(Surface Induced Plasma Chemical Processing, SPCP.) The electrode, however, has a structural disadvantage that a highly energetic plasma region is localized near the electrode surface, which may make it impossible for higher efficiency to realize. In an attempt to overcome this advantage, we have developed a hybrid reactor which employs a corona discharge unit together with the surface discharge unit. Experimental results suggest that the efficiency of the ozone production rate is improved when positive corona discharge is added.

  • PDF

Study on Multi-scale Unit Commitment Optimization in the Wind-Coal Intensive Power System

  • Ye, Xi;Qiao, Ying;Lu, Zongxiang;Min, Yong;Wang, Ningbo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1596-1604
    • /
    • 2013
  • Coordinating operation between large-scale wind power and thermal units in multiple time scale is an important problem to keep power balance, especially for the power grids mainly made up of large coal-fired units. The paper proposes a novel operation mode of multi-scale unit commitment (abbr. UC) that includes mid-term UC and day-ahead UC, which can take full advantage of insufficient flexibility and improve wind power accommodation. First, we introduce the concepts of multi-scale UC and then illustrate the benefits of introducing mid-term UC to the wind-coal intensive grid. The paper then formulates the mid-term UC model, proposes operation performance indices and validates the optimal operation mode by simulation cases. Compared with day-ahead UC only, the multi-scale UC mode could reduce the total generation cost and improve the wind power net benefit by decreasing the coal-fired units' on/off operation. The simulation results also show that the maximum total generation benefit should be pursued rather than the wind power utilization rate in wind-coal intensive system.