• Title/Summary/Keyword: unit disc

Search Result 187, Processing Time 0.023 seconds

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.

Fracture Toughness Evaluation and Influence Parameter Analysis by Numerical Simulation of Brazilian Test (Brazilian시험의 수치해석 시뮬레이션을 통한 파괴인성 산정 및 영향변수 분석)

  • Synn, Joong-Ho;Park, Chan;Shin, Hee-Soon;Chung, Yong-Bok;Lee, Hi-Keun
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.67-75
    • /
    • 2000
  • The numerical simulation of Brazilian fracture toughness test is carried out using PFC code and the influence parameters are analyzed such as shape of loading plane, size of Brazilian disc and unit panicle of model, loading angle and loading rate. The flattened Brazilian disc is adopted for applying uniform load. The range of loading angle(2$\alpha$) necessary to induce the tensile crack at disc center and to obtain the load-displacement curve giving the critical load for the stable crack propagation is shown as 20$^{\circ}$~40$^{\circ}$. In condition that the loading angle is 20$^{\circ}$, the mode-I fracture toughness is evaluated almost constant in the range of particle size less than I mm and loading rate less than 0.01 mm/s. This range of influence parameters seems appropriate condition for the tensile crack initiation at disc center and the control of stable crack propagation, which can give the reliance in evaluation of fracture toughness by Brazilian test.

  • PDF

Fracture Toughness Evaluation and Influence Parameter Analysis by Numerical Simulation of Brazilian Test (Brazilian 시험의 수치해석 시뮬레이션을 통한 파괴인성 산정 및 영향변수 분석)

  • Synn, Joong-Ho;Park, Chan;Shin, Hee-Soon;Chung, Yong-Bok;Lee, Hi-Keun
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.320-328
    • /
    • 2000
  • The numerical simulation of Brazilian fracture toughness test is carried out using PFC code and the influence parameters are analyzed such as shape of loading plane, size of Brazilian disc and unit particle of model, loading angle and loading rate. The flattened Brazilian disc is adopted for applying uniform load. The range of loading angle(2$\alpha$) necessary to induce the tensile crack at disc center and to obtain the load-displacement curve giving the critical load for the stable crack propagation is shown as 20°∼40°. In condition that the loading angle is 20°, the mode-I fracture toughness is evaluated almost constant in the range of particle size less than 1 mm and loading rate less than 0.01㎜/s. This range of influence parameters seems appropriate condition for the tensile crack initiation at disc center and the control of stable crack propagation, which can give the reliance in evaluation of fracture toughness by Brazilian test.

  • PDF

A Study on the Establishment of Disc Braking Force Pattern to reduce the Wear Mass of Pad (패드 마모량 감소를 위한 디스크 제동력 패턴 설정에 관한 연구)

  • Kim, Seog-Won;Kim, Young-Guk;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.786-791
    • /
    • 2007
  • Korean high speed train(HSR-350x) has adopted a combined electrical and mechanical(friction) braking system. Brake blending control unit(BBCU) controls each brake system to fulfill the required brake performances such as braking distance, deceleration and jerk. Also the braking system should be designed considering the economical management, such as effective use of generated braking energy and the minimum wear of friction materials(a pad and a brake shoe). In this paper, we establish the disc braking force pattern that reduces the wear of pad in the disc braking system by minimizing the variance of the instantaneous disk baking energy during braking time, and compare the wear mass of pad between the conventional disc braking force pattern and the established results.

  • PDF

The Spectral and Thermal Properties of Styrylquinolium Salts for Disc-Recordable Dyes

  • Song, Dong-Hyun;Kim, Jae-Pil;Lee, Chul-Joo;Park, Ki-Hong
    • Journal of Photoscience
    • /
    • v.8 no.3_4
    • /
    • pp.113-117
    • /
    • 2001
  • Several styrylquinolium salts were synthesized to investigate their absorption and thermal properties, which had five different p-aminobenzene units and three different counter ions (iodide, perchlorate, and hexafluorophosphorate anion), respectively. Hydroxy, methoxy, and methyl group in the meta position to the amino group led to bathochromic shift, while Ν-ethyl-Ν-chloroethylamino unit instead of Ν,Ν-diethylamino unit resulted in hypsochromic shift. A dye having a methoxy group in the meta position to the amino group had the highest molar extinction coefficient ($\xi$), while a dye carrying chloro group in Ν-alkyl chains had the lowest $\xi$. The type of counter ions had no effect on spectral properties like the maximum absorption wavelength and $\xi$. All styryl dyes had exothermic peaks at decomposition in DSC curves. Among these styryl dyes, S2 series with perchlorate anions showed the strongest exothermic decomposition. From TGA spectra, S3 series with hexafluorophosphorate anions had the best thermal stability and the sharpest threshold at thermal decomposition.

  • PDF

Modelling of timber joints made with steel dowels and locally reinforced by DVW discs

  • Guan, Zhongwei;Rodd, Peter
    • Structural Engineering and Mechanics
    • /
    • v.16 no.4
    • /
    • pp.391-404
    • /
    • 2003
  • Local reinforcement in dowel type timber joints is essential to improve ductility, to increase load carrying capacity and to reduce the risk of brittle failure, especially in the case of using solid dowel. In many types of reinforcing materials available today, DVW (densified veneer wood) has been demonstrated to be the most advantages in terms of compatibility, embedding performance and ductility. Preliminary studies show that using appropriately sized DVW discs bonded into the timber interfaces may be an effective way to reinforce the connection. In this paper, non-linear 3-dimensional finite element models, incorporating orthotropic and non-linear material behaviour, have been developed to simulate structural performance of the timber joints locally reinforced by DVW discs. Different contact algorithms were applied to simulate contact conditions in the joints. The models were validated by the corresponding structural tests. Correlation between the experimental results and the finite element simulations is reasonably good. Using validated finite element models, parametric studies were undertaken to investigate effects of the DVW disc sizes and the end distances on shear stresses and normal stresses in a possible failure plane in the joint.

Thermal Analysis of a Liquid Hydrogen Vessel with Multi-Layer-Insulation and Vapor-Cooled Shield (다층단열재와 증기냉각쉴드를 사용한 액체수소 저장용기의 열해석)

  • Jung, Il-Kwon;Kang, Byung-Ha
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.3
    • /
    • pp.284-289
    • /
    • 2005
  • Thermal analysis of cryogenic-capable vessels with insulations have been carried out to store liquid hydrogen($LH_2$). The combined insulations of MLI(Multi-Layer Insulation) and VCS(Vapor-Cooled Shield) under high vacuum are considered in the analysis for various volumes of vessels. Vapor-Cooled Shields(VCS) are installed at cylinder wall as well as disc side of the $LH_2$ vessels. The results indicate that optimal distribution of boiloff vapor from $LH_2$ vessel into two sides of VCS exists based on the evaporation loss. As the volume of $LH_2$ vessel is increased, mass flow rate of boiloff is increased while the evaporation loss per unit volume is decreased.

A Study on the Evaluation of Compression Force at the L5/S1 using Electromyography (근전도를 이용한 L5/S1에서의 요추부하 평가에 관한 연구)

  • 양성환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.323-332
    • /
    • 1997
  • This study evaluated the compression force at the L5/S1 disc using EMG(Electromyography). EMG signals were analyzed under the condition of fixed vertical factor (20Cm∼80Cm), two horizontal factors (35Cm, 55Cm), and two weight factors (10Kg, 25Kg) 2 times per minute for each posture. Also, the result was compared with the compression force of each posture which computated by the equation of NIOSH(National Institute for Occupational Safety and Health) guide to manual lifting(1991). The experimental result show that EMG signals have more an effect on the Weight than the Horizontal factors. Also, there are not significant differences on the analysis result of EMG signals between Health members and not, because the body buildings which doing Health members are not enhanced the motor unit due to the MMH(Manual Material Handing).

  • PDF

INEQUALITIES FOR THE NON-TANGENTIAL DERIVATIVE AT THE BOUNDARY FOR HOLOMORPHIC FUNCTION

  • Ornek, Bulent Nafi
    • Communications of the Korean Mathematical Society
    • /
    • v.29 no.3
    • /
    • pp.439-449
    • /
    • 2014
  • In this paper, we present some inequalities for the non-tangential derivative of f(z). For the function $f(z)=z+b_{p+1}z^{p+1}+b_{p+2}z^{p+2}+{\cdots}$ defined in the unit disc, with ${\Re}\(\frac{f^{\prime}(z)}{{\lambda}f{\prime}(z)+1-{\lambda}}\)$ > ${\beta}$, $0{\leq}{\beta}$ < 1, $0{\leq}{\lambda}$ < 1, we estimate a module of a second non-tangential derivative of f(z) function at the boundary point ${\xi}$, by taking into account their first nonzero two Maclaurin coefficients. The sharpness of these estimates is also proved.

Applications of Convolution Operators to some Classes of Close-to-convex Functions

  • Noor, Khalida Inayat
    • Honam Mathematical Journal
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 1988
  • Let C[C, D] and $S^{*}[C,\;D]$ denote the classes of functions g, g(0)=1-g'(0)0=0, analytic in the unit disc E such that $\frac{(zg{\prime}(z)){\prime}}{g{\prime}(z)}$ and $\frac{zg{\prime}(z)}{g(z)}$ are subordinate to $\frac{1+Cz}{1+Dz{\prime}}$ $z{\in}E$, respectively. In this paper, the classes K[A,B;C,D] and $C^{*}[A,B;C,D]$, $-1{\leq}B<A{\leq}1$; $-1{\leq}D<C{\leq}1$, are defined. The functions in these classes are close-to-convex. Using the properties of convolution operators, we deal with some problems for our classes.

  • PDF