Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection (표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계)

  • Cho, Eun Deok;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

A Study on the Buckling Characteristics of Single-Layer Latticed Domes under Equipment-Loading (설비하중을 고려하는 단층래티스돔의 좌굴특성에 관한 연구)

  • 박지영;정환목;권영환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.04a
    • /
    • pp.83-88
    • /
    • 1994
  • Recently, the equipments of the structure are increasing remarkably. It is very important to evaluate the stability of the domes under concentrated loading such as a large-scale illuminating, visional, and sound equipment. The paper is aimed at investigating the buckling characteristics of single-layer latticed domes with triangular network under the uniformly distributed vertical-loading and the partially concentrated equipment-loading. The results show that the effects of the equipment-loading on the buckling strength is much more sensitive in domes of overall buckling than in domes of member buckling.

  • PDF

Improvement of Color Temperature Uniformity of Integrated Optic Lens Type LED Packaged using Compression Molding Method (가압성형 방식을 사용한 렌즈 일체형 LED 패키지의 색온도 균일성 향상에 관한 연구)

  • Kim, Wan-Ho;Kang, Young-Rae;Jang, Min-Suk;Joo, Jae-Young;Song, Sang-Bin;Kim, Jae-Pil;Yeo, In-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • Optical characteristics including the view angle and color temperature uniformity of LED packages with an integrated lens fabricated by compression molding method are investigated according to lens shape, lens materials, and phosphor coating methods. Four types of lens shape are designed and their optical output power dependence on the refractive index of silicone encapsulant are evaluated. Also, spatial color temperature uniformities of packages fabricated with different phosphor coating methods-direct coating on a chip vs. uniformly mixed with silicone encapsulant- are compared at various view angles. As the result, it is found that phosphor coating method is more effective on color temperature uniformity than lens shape. The maximum color temperature difference of a package with direct coating of phosphor on a chip is 1,340K according to the view angle at the color temperature of 5,000K, and that of a package with uniformly mixed phosphor is 250K, which indicates 1,090K improvement of color uniformity for the latter case.

The Analysis of Fatigueness and Preference for Three Appearance Attributes of LED Light Color (LED 광색의 삼속성에 따른 피로도와 선호도 분석)

  • Baek, Chang-Hwan;Kim, Youn-Jin;Kim, Hong-Suk;Park, Seung-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.18-29
    • /
    • 2011
  • Light emitting diode(LED) technology has been increasingly developed and larger color gamut by LED illuminations can be reproduced; therefore more efficient LED lighting design can be accomplished under a consideration of color emotion. Fifty-two LED colors which are uniformly distributed on the uniform chromaticity space are evaluated in terms of fatigueness and preference and their relation to three color-appearance attributes(lightness, chroma and hue) are investigated. As a result, 23 human observers likely to prefer and feel comfortable, when lightness of a given LED color stimulus increases as well as its chroma decreases. The highest fatigueness score is observed in red color series and the most preferred LED color is found in green color series. In addition, fatigueness and preference show a strong negative linear relation and their Pearson correlation is higher than -0.8.

Aging-Time Dependence of Color Rendering Index of a LED Lamp for Lighting (조명용 LED 램프의 사용 시간에 따른 연색지수 특성변화)

  • Son, Minwoo;Lee, Duck Hee;Seo, Jung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • We measured color rendering index(CRI) of a LED lamp for lighting for aging-time. We chose bulb type white LED lamp six samples and halogen lamp one sample and applied 220V, 60Hz to all the samples for 1,000hours at ordinary temperature. The CRI was measured every 20hours and the CRI change of the LED lamp was compared with the halogen lamp's CRI change. As time goes, efficiency of the halogen lamp decreased and the CRI maintained uniformly. The other hand, efficiency of the LED lamp decreased but the CRI increased. The CRI of the LED lamp has been stabilized since 600hours. The CRI change of the LED lamp was analyzed with a spectrum, color coordinate and color temperature.

The Development of High Efficiency Tempering System using Microwave (마이크로파를 이용한 고 효율 해동 시스템 개발)

  • Cho, Kook-Hee;Park, Seung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.69-74
    • /
    • 2009
  • The tempering system which is developed by this research which sees energy curtailment and from the environmental side which is essential for in hazard analysis critical control point. The tempering system with development experimented frozen pork and fish. As test result, frozen pork region was not thawed occurred plentifully. Like this the actual condition, the case of frozen fish is grind and the bulk and density uniformly was formed, the pork the density was dense and was thought with the fact that the temperature difference change is big. Also after tempering from measurement location center the temperature appeared substitutionally with the low-end thing. This central part of the frozene region is thought the impedance change appears few. To hereafter respects an impedance change is thought that has the necessity which will change the structure of tempering system.

COMPARISON OF TWO SCATTERING PHASE FUNCTIONS IN MULTIPLE SCATTERING ENVIRONMENT (다중산란 환경에서의 두개의 산란 위상함수 비교)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.25 no.4
    • /
    • pp.113-118
    • /
    • 2010
  • The Henyey-Greenstein (H-G) phase function, which is characterized by a single parameter, has been generally used to approximate the realistic dust-scattering phase function in investigating scattering properties of the interstellar dust. Draine (2003) proposed a new analytic phase function with two parameters and showed that the realistic phase function is better represented by his phase function. If the H-G and Draine's phase functions are significantly different, using the H-G phase function in radiative transfer models may lead to wrong conclusions about the dust-scattering properties. Here, we investigate whether the H-G and Draine's phase functions would indeed produce significant differences in radiative transfer calculations for two simple configurations. For the uniformly distributed dust with an illuminating star at the center, no significant difference is found. However, up to ~ 20% of difference is found when the central star is surrounded by a spherical-shell dust medium and the radiation of $\lambda$ < $2000\;{\AA}$ is considered. It would mean that the investigation of dust-scattering properties using the H-G phase function may produce errors of up to ~ 20% depending on the geometry of dust medium and the radiation wavelength. This amount of uncertainty would be, however, unavoidable since the configurations of dust density and radiation sources are only approximately available.

Temperature Rise and Dielectric Characteristics of Distribution Transformers with Over-Loading Operation (배전용변압기의 부하운전에 의한 온도 및 유전특성 분석)

  • Kim, Byung-Sook;Lee, Byung-Sung;Song, Il-Keun;Han, Byoung-Sung;Joung, Jong-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.104-110
    • /
    • 2007
  • Temperature rise characteristics of medium voltage class transformers and dielectric characteristics of its insulation oil according to the loading rate were investigated using the transformer that has thermocouples embedded in the windings. The hottest-spot of the transformer locates at about 2/3 height of the windings where they adjoin each other among the 3 phase windings. The temperature difference between the hottest-spot and top-oil is about $17[^{\circ}C]$ and the value keeps uniformly in short time after changing the loading rate. Capacitance of the oil varies in inverse proportion to temperature and the inclination rate is about -0.0106 that is not dependent on the aging rate. On the other hand the capacitance is increased depending on the aging rate, so the capacitance characteristics of the oil could be applied to the diagnostic technique.

A Risk Assessment in According to Spot Measures and Analysis in Dust Generation Area (분진발생지역의 현장실측과 분석을 통한 위험성 평가)

  • Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.103-110
    • /
    • 2008
  • In terms of electrical safety, environmental impact assessment and revision of domestic regulation are needed for the electric facilities. In this paper, risk of electric facilities is assessed by the spot measures and analysis in dust generation area. Adhesion dust in a surface of insulated materials cause electrical accidents. In a mechanism of these accidents, when the dust lie on electric facilities, a leakage current is flowed and the surface of insulated material is carbonized. Hereafter, electrical fire is generated due to Joule's heat. As the results, dusts are found in protection devices or panel board and sampled dusts vary in sampled amounts and conductivity severally. For the most part, sodium is detected but zinc and calcium are detected in case of reclaimed rubber factory by the ICP-AES(Inductively Coupled Plasma-Atomic Emission Spectroscopy). In a sewerage, the ingredients such as sodium, magnesium, iron, calcium, aluminium, etc are detected uniformly. So that, results of the spot measures and analysis of dusts are become the important data for the assessment of electrical hazard in dust generation area.