A Study on the Protect Measures and Impact of Electric Pole for Abnormal Tension of Messenger Wire (조가선 이상 장력 작용에 대한 전주의 영향 및 보호 대책 연구)

  • Oh, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.78-83
    • /
    • 2006
  • In this study, we analyzed the influence or electrical pole by FEM(Finite Element Method) and developed protective system by designing and interpreting protective system for electrical pole when abnormal strength worked on messenger wire. Protective system did not shed messenger wire under wind pressure and discontent load but did assign a part to preventing rupture of electrical pole through automatically shed messenger wire over fred strength. Structure of protective system analysis by FEM and prove property by measuring tensile strength for practical product.

A Numerical Model of Three-dimensional Soil Water Distribution for Drip Irrigation Management under Cropped Conditions (작물 흡수를 고려한 3차원 토양수분 분포 모델 개발을 통한 최적 점적 관개 연구)

  • Kwon, Jae-Phil;Kim, Seung-Hyun;Yoo, Sun-Ho;Ro, Hee-Myong
    • Applied Biological Chemistry
    • /
    • v.43 no.2
    • /
    • pp.116-123
    • /
    • 2000
  • A numerical model of three-dimensional soil water distribution for drip irrigation management under cropped conditions was developed using Richards equation in Cartesian coordinates. The model accounts for both seasonal and diurnal changes in evaporation and transpiration, and the growth of plant root and the shape of root zone. Solutions were numerically approximated using the Crank-Nicolson implicit finite difference technique on the block-centered grid system and the Gauss-Seidel elimination in tandem. The model was tested under several conditions to allow the flow rates and configurations of drip emitters vary. In general, simulation results agreed well with experimental results and were as follows. The velocity of soil-water flow decreased drastically with distance from the drip source, and the rate of expansion of the wetted zone decreased rapidly during irrigation. The wetting front of wetted zone from a surface drip emitter traveled farther in vertical direction than in horizontal direction. Under this experimental weather condition, water use efficiency of a drip-irrigated apple field was greatest for 4-drip-emitter system buried at 25 cm, resulting from 10% increase in transpiration but 20% reduction in soil evaporation compared to those for surface 1-drip emitter system. Soil moisture retention curve obtained using disk tension infiltrometer showed significant difference from the curve obtained with pressure plate extractor.

  • PDF

A Study on the Characteristics of High Temperature and Mechanisms for Creep Deformation of AZ31 Mg Alloy (AZ31마그네슘 합금의 고온특성 및 크리이프 변형기구에 관한연구)

  • Kang, D.M.;An, J.O.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.96-101
    • /
    • 2005
  • Magnesium alloys have been widely used for many structural components of automobiles and aircraft because of high specific strength and good cast ability in spite of hexagonal closed-packed crystal structure of pure magnesium. In this study, uniaxial tension tests at high temperature and creep tests are done in order to investigate the characteristics of high temperature and mechanisms for creep deformation of AZ31 Mg alloy. Yield stress and ultimate tensile stress decreased with increasing temperature, but elongation increased from results of uniaxial tension test at high temperature. The apparent activation energy Qc, the applied stress exponent n and rupture life have been determined during creep of AZ31 Mg alloy over the temperature range of 473K to 573K and stress range of 23.42 MPa to 93.59 MPa, respectively, in order to investigate the creep behavior. Constant load creep tests were carried out in the equipment including automatic temperature controller, whose data are sent to computer. At around the temperature of $473K{\sim}493K$ and under the stress level of $62.43{\sim}93.59%MPa$, and again at around the temperature of $553K{\sim}573K$ and under the stress level of $23.42{\sim}39.00MPa$, the creep behavior obeyed a simple power-law relating steady state creep rate to applied stress and the activation energy for the creep deformation was nearly equal, respectively, and a little low to that of the self diffusion of Mg alloy including aluminum. Also rupture surfaces at high temperature have had bigger dimples than those at lower temperature by SEM.

  • PDF

A Study on the Experience of Fundamental Nursing Practice (간호 대학생의 기본 간호 실습 경험에 대한 연구)

  • 한경순;조주연
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.293-303
    • /
    • 1999
  • The purpose of this study was to understand and to explain how were nursing students experienced and accepted the fundemental nursing practice. In addition to, the results of this study are attempted to contribute for offer of basic data in projecting and accomplishing to promote quality practice education. The participants were 79 freshmen of S College of Nursing in kyungi-do. They presented record of feeling and thinking on their the fundemental nursing practice experience. The data were collected from 29, J une to 10, July in 1998. Collected data was analyzed by means of Van Kaam's phenomenological method. The results of this study was founded 423 descriptive expression and they were grouped under 42 common factors and they were grouped under 9 categories. By means of the frequency on the categories. the higher category is Anxiety. next Solemn. Flutter. Pride. Usefulness, Recognition of reality in nursing-system. Lack of practice environment. Self-accusation. Comprehension of nursing spirit were founded. 5 common factors. Tension. Difficulty, Dread. Apprehension, Burden were grouped under Anxiety. 7 common factors, Pledge, Memory, Importance of practice, Sincerity, Restriction of dress, Acceptance, Active attitude were grouped under solemn. 5 common factors, Interest, Strange, Beanimated, Waiting, Curiosity were grouped under Flutter. 5 common factors, Conceit, Self-confidence, Skilled, Worth, Accomplishment were grouped under Pride. 6 common factors, Acknowledge of nursing affairs, Expectation of furture, Fascination of nursing. Acquirement of disposition of nurse, Association of injection, Actual feeling of dept. of nursing were grouped under Recognition of reality in nursing-system. 4 common factors, Lack of practice time, Many persons of practice, Lack of practice instrument, Lack of reality were grouped under Lack of practice envirnment. 5 common factors, Inconvenient, Reflection, Loss of pride, Shyness, Feeling sorry were grouped under Self-accusation. 3 common factors, Utility, Connection of practice and theory, Various experience were grouped under Usefulness. 2 common factors, Comprehension on the dignity of human, Comprehension on a point of view of patient were grouped under Comprehension of nursing spirit. In conclusion, the following recommendation should be necessary a supplementary study to approach on the type of students that has a firm view and care about client prior to clinical nursing practice.

  • PDF

Dynamic Analysis on Belt-Driven Spindle System of Machine Tools

  • Kim, Seong-Keol
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.3
    • /
    • pp.82-89
    • /
    • 2002
  • The need of ultra-precision machine tools, which manufacture and machine the high precision parts used in computers, semi-conductors and other precision machines, has been increased over years. Therefore it is important to design the driving parts, which affect significantly on their performances. In this paper, the dynamic analyses on the belt-driven system were explored. Relation of the acoustical natural frequency and the tension of belt was derived and presented through experiments. Also, while the dynamic loads on motor system were changed, dynamic deflections were calculated through finite element analysis. Nonlinear characteristics of the bearings having an effect on the dynamic performance were studied and the belt connecting the motor (driving part) to spindle of a machine tool (driven part) was modeled as truss and beam elements fur simulations under various conditions, and a beam element model was verified to be more useful.

Protect Measures and Impact of Electric Pole for Abnormal Tension of Messenger Wire (전력선 벤드 장력 작용에 대한 전주의 영향)

  • Cho, Hyeon-Seob;Kim, Young-Cho;Kim, Sung-Woon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.302-306
    • /
    • 2006
  • In this study, we analyzed the influence of electrical pole by FEM(Finite Element Method) and developed protective system by designing and interpreting protective system for electrical pole when abnormal strength worked on messenger wire. Protective system did not shed messenger wire under wind pressure and discontent load but did assign a part to preventing rupture of electrical pole through automatically shed messenger wire over fixed strength. Structure of protective system analysis by FEM and prove property by measuring tensile strength for practical product.

  • PDF

Analysis of Dynamic Behavior in GMAW System (GMA용접 시스템의 동적 거동에 대한 해석)

  • 이재영;최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.41-48
    • /
    • 2000
  • Dynamic behaviors of the GMAW system are simulated using the short-circuit transfer model and the characteristic equations fir the power supply, wire system and arc. The conventional wire equation, which relates the rate change of the wire extension to the wire feed rate and melting rate, is modified to include effects of the molten drop attached at the wire tip. The modified wire equation describes behaviors of the GMAW system more precisely and provides information about the initial bridge volume for short-circuit transfer. The proposed short-circuit model predicts the variation of parameters such as the current, voltage, short-circuit frequency and time considering the effects of the surface tension and electromagnetic force due to current. The calculated results are in broad agreements with the experimental results under the argon shielding condition.

  • PDF

Smart Card Reader기 Connector 조립 및 Vision 검사용 자동화기기 개발에 관한 연구

  • 노병옥;성하경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.543-548
    • /
    • 1994
  • This is the paper on the development of assemnly automation and visual inspection system for smart card reader connector. The automation consists of 3 main process injection, assembly and inspection. During the injection, the main pin of a reel. transferred under uniform tension, is cut with an injection interval and positioned precisely to an injection mold by roll feeder after injection. The main base is stacked to a magazine for main pin's exact positionning to a mold . For last effective production, The turn table and pick & place are driver with gears and came by a single monter. We developed the small parts handling technigue for stable supply of micro ist pin and 2nd pin and could determine the orientation and position of those pins. For reliable inspection, We used the vision system which examins the guality of arranged pins with a CCD camera. The connector models which can be manufactured with this system are 8 pin and 10 pin type. The user can select the connector model for production and adjust the torerable error range during the inspection of arranged pins.

  • PDF

An Experimental Analysis on the Motion Response of a Moored Semi-Submersible Platform in Regular Waves (계류된 반잠수식 시추선의 운동특성에 관한 실험적 고찰)

  • 홍사영;이판묵;홍도천
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.59-70
    • /
    • 1988
  • This paper presents the results of motion tests of a moored semi-submersible platform in regular waves. To investigate the effects of mooring system on the motion characteristics, the tests were performed under the various mooring conditions in regular head and beam waves. Two types of mooring system were employed: one is composed of soft springs and the other is of chains. In the case of chains the pretensions were varied to investigate the dynamic effects of mooring forces as well as the motion responses of the semi-submersible. The motion responses and mooring tensions were measured and analyzed by the double amplitude method. The measured motion responses were also compared with the results of calculation from three-dimensional potential theory. Finally, the dynamic behaviors of mooring chains were studied.

  • PDF

Cardiovascular Effects of Propofol Infused for Maintenance of Anesthesia in Dogs (개에서 Propofol 점적투여율 변화가 심혈관계에 미치는 영향)

  • 권영삼;장광호;장환수;박현정;임재현;오태호;엄기동;장인호
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.199-203
    • /
    • 2002
  • Cardiovascular effects of propofol, were assessed after premedication with xylazine(1.0 mUkg, IM) under oxygen supply(200 ml/kg/min) via a endotracheal tube. Twelve adult mixed-breed dogs were divided into four groups; 0.2(Group 1), 0.4(Group 2), 0.6(Group 3) and 0.8 mg/kg/min(Group 4) of propofol respectively. Arterial blood pressure and electrocardiogram were monitored with a physiograph after an arterial catheter was inserted into the femoral artery. pH, arterial carbon dioxide tension($PaCO_2$and arterial oxygen tension($PaO_2$) were evaluated with arterial blood collected through the inserted catheter. Diastolic arterial pressure, systolic arterial pressure and mean arterial pressure were decreased slightly in Group I IIand III, but decreased significantly in Group IV. They were increased rapidly after stopping propofol infusion in Group IV pH was maintained in normal range in Group I, II and m, but was decreased in proportion to time passing in Group IV. $PaCO_2$ was increased significantly only in Group IV but $PaO_2$ was maintained in normal range in all groups Although heart rate was recorded in normal range for 90 minutes, arythmia was noted after stopping propofol infusion in all groups. It was concluded that propofol depressed the cardiovascular system in proportion to infusion dosage, and 0.8 mg/kg/min of propofol infusion rate was not appropriated in canine anesthesia with xylazine premedication.