• Title/Summary/Keyword: unconfined

Search Result 735, Processing Time 0.03 seconds

Fire Resistance of Circular Internally Confined Hollow Reinforced Concrete Column (원형 내부 구속 중공 철근콘크리트 기둥의 내화 성능)

  • Won, Deok-Hee;Han, Taek-Hee;Lee, Gyu-Sei;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.139-150
    • /
    • 2010
  • Reinforced-concrete (RC) columns are frequently designed and constructed. other types of columns includes composite types such as concrete-filled tube columns (CFT). Hollow RC columns may be effective in reducing both the self weight of columns and total amount of materials used. This is due to the fact that a hollow RC column possesses larger moment of inertia than that of solid RC columns of same cross sectional area. Despite the effectiveness the hollow RC column has not been popular because of its poor ductility performance. While the transverse reinforcements are effective in controlling the brittle failure of the outside concrete, they are not capable of resisting the failure of concrete of inner face which is in unconfined state of stress. To overcome these drawbacks, the internally confined hollow reinforced concrete (ICH RC), a new column type, was proposed in the previous researches. In this study, the fire resistance performance of the ICH RC columns was analyzed through a series of extensive heat transfer analyses using the nonlinear-material model program. Also, effect of factors such as the hollowness ratio, thickness of the concrete, and thickness of the internal tube on the fire resistance performance were extensively studied. Then the factors that enhance the fire-resistant performance of ICH RC were presented and analyzed.

Hazard Distance from Hydrogen Accidents (수소가스사고의 피해범위)

  • Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • An analysis was completed of the hazards distance of hydrogen accidents such as jet release, jet fire, and vapor cloud explosion(VCE) of hydrogen gas, and simplified equations have been proposed to predict the hazard distances to set up safety distance by the gas dispersion, fire, and explosion following hydrogen gas release. For a small release rate of hydrogen gas, such as from a pine-hole, the hazard distance from jet dispersion is longer than that from jet fire. The hazard distance is directly proportional to the pressure raised to a half power and to the diameter of hole and up to several tens meters. For a large release rate, such as from full bore rupture of a pipeline or a large hole of storage vessel, the hazard distance from a large jet fire is longer than that from unconfined vapor cloud explosion. The hazard distance from the fire may be up to several hundred meters. Hydrogen filling station in urban area is difficult to compliance with the safety distance criterion, if the accident scenario of large hydrogen gas release is basis for setting up the safety distance, which is minimum separation distance between the station and building. Therefore, the accident of large hydrogen gas release must be prevented by using safety devices and the safety distance may be set based on the small release rate of hydrogen gas. But if there are any possibility of large release, populated building, such as school, hospital etc, should be separated several hundred meters.

Quality Grading of Concrete Soil Erosion Control Dam in the Aspect of Unconfined Concrete Strength by Surface-Wave Technique (표면파 기법에 의한 콘크리트 사방댐의 콘크리트 강도 등급 평가)

  • Lee, Chang-Woo;Joh, Sung-Ho;Park, Ki-Hyung;Kim, Min-Sik;Yoon, Ho-Joong;Raja Ahmad, Raja Hassanul
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.412-425
    • /
    • 2012
  • Concrete Soil Erosion Control Dam, which blocks flow of debris flow in torrential stream, are reported to lose expected functions due to structural failure and collapses, caused by poor construction, material deterioration and external impacts. In this paper, an integrity assessment technique for debris barriers was proposed, which allows preliminary detection of problems inherent in debris barriers. The proposed integrity assessment technique is a non-destructive method based on SASW method, one of surface-wave tests. In this paper, a practical procedure and analysis guidelines in applying the SASW technique to debris barrier was proposed and its validity was verified using five decrepit debris barriers older than 20-year old. As a result, the SASW method was validated for the reliable grade evaluation method for concrete soil erosion control dam, and the resulting grades turned out to agree with the results determined by Sabang Associations.

Capacity and Length of Compression Lap Splice in Unconfined Concrete of 100MPa and Less Compressive Strength (횡보강근이 없는 100 MPa 이하 콘크리트의 철근 압축이음 강도와 이음길이)

  • Chun, Sung-Chul;Lee, Sung-Ho;Oh, Bo-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.659-666
    • /
    • 2010
  • Although the compression splice needs not be longer than the tension slice due to existence of end bearing, current design codes impose a longer compression lap splice than a tension lap splice in high strength concrete. Hence, new criteria for the compression lap splice including the effects of concrete strength need to be sought for economical design involving ultra-high strength concrete. An experimental study has been conducted with column specimens in concrete strength of 80 and 100 MPa. Test results show that the splice strength can be evaluated to be proportional to square root of compressive strength of concrete. Bar stress developed by end bearing is not affected by splice length and is expressed with a function of the square root of concrete strength. Mean value of stresses developed by end bearing is 16.5 square root of $f_{ck}$. The stresses developed by bond in compression splices are nearly identical to those in tension splices and, therefore, strength increment of compression splices is attributed to end bearing only. From regression analysis of 58 tests, a design equation is proposed for compression lap splice in 40 to 100 MPa of compressive strength of concrete. By the proposed equation, the anomaly of lap lengths in tension and compression is got rid of. In addition, the equation has a reliability equivalent to those of the specified strengths of materials.

A Study on Environmental and Economic Analysis for Each Treatment of Sewage Sludge(III) - Results of Environmental Assessment - (하수슬러지 처리방법별 환경성 및 경제성 분석에 대한 연구(III) - 환경성 분석 중심으로 -)

  • Bae, Jisu;Lee, Suyoung;Cho, Yuna;Kwon, Younghyun;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.5-13
    • /
    • 2016
  • This study investigated the environmental and economical assessment for sewage sludge treatment options including biogasification, incineration, carbonization, drying, and solidification. For the economical feasibility the 30 plants with anaerobic digestion treatment and the 17 plants without anaerobic digestion treatment were investigated. In regarding to the environmental assessment, the air emission pollutants (SOx, NOx, etc) from incineration and carbonization plants were assessed and 1~34 % of emission limits was emitted. Drying and solidification plants emitted about 30 % of odour limits. And the rest of the pollutants were emitted either at not-detectable level or at below the limits. When the by-products from the solidification treatment was used as landfill cover materials, the unconfined compression strength could be below the limit and it could cause an unsafe condition for those passing vehicles and the possibility of the ground subsidence. There has been a maintenance difficulty due to frequent blockage and operational failure. The result of the comparison of sewage sludge treatment options showed that anaerobic digestion+incineration was the most economically feasible considering incineration and drying. For smaller treatment capacity, solidification was the most economically feasible considering carbonization and solidification and anaerobic digestion+carbonization was the most economically feasible considering carbonization and solidification.

Hydrogeological Properties of Uunconsolidated Formations and Bedrocks in the Central Area of Busan Metropolitan City (부산 도심지역 미고결층과 기반암의 수리지질 특성)

  • Hamm Se-Yeong;Cha Yong-Hoon;Cheong Jae-Yeol
    • The Journal of Engineering Geology
    • /
    • v.15 no.4 s.42
    • /
    • pp.407-421
    • /
    • 2005
  • This study aims to investigate hydrogeological properties of the central area from Yangjeong-Dong to Sujeong-Dong in Busan Metropolitan City. For this study, pumping tests were carried out in the bedrock aquifer of Yangjeong-Dong and the unconsolidated aquifer near Busanjin railway station. The pumping test in the bedrock aquifer containing the Dongrae fault revealed specific hydraulic characteristics with respect to the fault. The pumping test in the unconsolidated aquifer revealed the hydrogeologic properties of both coastal landfill and fine sediments. It was found that the Moench's sphere-shaped dual-porosity model fits the bedrock aquifer, whereas the Neuman's uncofined aquifer model accords with the unconsolidated aquifer. The average transmissivity and storage coefficient of the bedrock aquifer are $2.75{\times}10^{-5}m^2/s\;and\;6.41{\times}10^{-5}$ and those of the unconsolidated aquifer are $8.24{\times}10^{-4}m^2/s\;and\;3.70{\times}10^{-3}$, respectively. On the other hand, slug tests gave average transmissivity and storage coefficient values of $9.84{\times}10^{-4}m^2/s\;and\;1.21{\times}10^{-2}$, respectively.

Effect of Curing Temperature on the Strength Characteristics of Lightweight Air-Trapped Soil (양생온도가 경량기포토의 강도에 미치는 영향)

  • Lee, Min-Ah;Kim, Seong-Won;Choi, Dae-Kyung;Park, Lee-Keun;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.4
    • /
    • pp.43-53
    • /
    • 2012
  • There are many factors that can cause problems in the application of the lightweight air-trapped soil in the field. Temperature is one of them. However, the effect of temperature on the characteristics of lightweight air-trapped soil has not been studied. Thus, this experimental study is conducted. This study considers three different unit weights of lightweight air-trapped soils, 6, 8, and 10 kN/$m^3$ which are mostly applied to the field. The lightweight air-trapped soil specimens are cured in the condition of different temperatures based on the characteristic of temperature of Korea. The unconfined compression tests are conducted on the prepared specimens. The settlement behavior of lightweight air-trapped soil on temperature is observed. A photograph is taken using SEM to determine the transformation of air-foams inside the lightweight air-trapped soil on curing temperature. As the results, the effect of curing temperature on the characteristics of lightweight air-trapped soil including compressive strength, settlement, and formation of air-foams is confirmed. Finally, based on this study, the allowable curing temperature of $8^{\circ}C{\sim}25^{\circ}C$ which can guarantee the quality of lightweight air-trapped soil is proposed.

Hydraulic Conductivity and Strength Characteristics of Self Recovering Sustainable Liner (SRSL) as a Landfill Final Cover (SRSL 매립지 최종 복토층의 투수 및 강도 특성)

  • Kwon, Oh-Jung;Lee, Ju-Hyung;Cho, Wan-Jei;Jung, Young-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.12
    • /
    • pp.5-15
    • /
    • 2011
  • Conventional designs of landfill covers use geosynthetics such as geomembrane and GCL, and clay liners to lower the permeability of final covers of landfill sites. However, differential settlement and the variation of temperature or humidity in landfill sites cause the development of cracks or structural damage inside the final cover. This study examined the application of a Self Recovering Sustainable Liner (SRSL) as an alternative landfill final cover material. SRSL consists of double layers, which have chemicals, can generate precipitates filling the pores of the layers by chemical reaction. The interface material forms an impermeable layer and in case of internal cracks, the reactants of the two layers migrate towards the crack and heal it by forming another liner. In this study the applicability of SRSL material for landfill final cover was examined by performing flexible wall permeameter tests to prove that the hydraulic conductivity is lower than the regulations and unconfined compression tests to judge whether the strength satisfies the restriction for the landfill final cover. Furthermore, the environmental impacts on the permeability and strength were evaluated. The experimental results show that the SRSL has lower hydraulic conductivity and higher strength than the regulations and is little influenced by climatic changes such as wet/dry or freeze/thaw process.

Influence of Sulfate on the Early Hydration in the Solidification of Lime-tailings (소석회-광물찌꺼기 고형화의 초기 수화에 미치는 황산염의 영향)

  • Lee, Hyun-Cheol;Min, Kyoung-Won;Yoo, Hwan-Geun
    • Economic and Environmental Geology
    • /
    • v.46 no.6
    • /
    • pp.535-544
    • /
    • 2013
  • Influence of sulfate on the early hydration in the solidification treatment of abandoned mine tailings was characterized. Solidified specimens using hydrated lime as a binder were prepared with various amounts of added $Na_2SO_4$ and different curing days. Unconfined compressive strength measurement, heavy metal leaching test, XRD analysis were performed after 7-, 14- and 28-days curing. According to curing days strength of solidified specimens using only distilled water increased but those with addition of $Na_2SO_4$ decreased. External cracks of specimens developed definitely with increasing $Na_2SO_4$ concentration and curing days. Concentrations of Cu, Cd, Zn, and As in the leached solutions from solidified specimens decreased significantly but Pb was leached readily in cases of hydrated lime dosage more than 10 wt%. Gypsum and $MgSO_4$ were identified in the cracked solidified specimens by XRD analysis, and pillar-shaped crystals of SEM image were identified as gypsum in reference with EDS analysis. Crystallization of sulfate in the process of lime-tailing solidification caused cracking, which should be supplemented for solidification treatment of highly sulfur-contained tailing.

Review of Nitrous Oxide Emission by Denitrification in Subsurface Soil Environment (심층토에 있어서 탈질화에 의한 $N_2 O$ 방출의 평가)

  • Chung Doug-Young;Jin Hyun-O;Lee Chaang-Hwan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.2
    • /
    • pp.160-164
    • /
    • 1999
  • Subsurface environments, including the intermediate vadose zone and aquifers, may be contributing to increased atmospheric concentrations of $N_2$O. Denitrification appears to be the major source of $N_2$O in the subsurface environment. In the intermediate vadose zone, the level of denitrifying activity is dependent on the soil morphology, particularly stratified layers within the soil profile, which impede water and solute movement and create conditions favorable for denitrification. Movement of organic C from the soil surface appears to support denitrifying activity by providing an energy source and increasing the consumption of $O_2$. Denitrirication and $N_2$O production have been observed in aquifers but appear to be of greatest significance in shallow unconfined aquifers. The lack of organic C, N $O_2$, or anaerobiosis is often a limiting factor for activity but seems to be site specific. The presence of denitrifying bacteria does not appear to be a major limitation, based on published results, but the ubiquity of denitrifiers in subsurface environments needs to be confirmed. The fate of the $N_2$O produced in subsurface environments is unknown. Transport of $N_2$O by up ward diffusion, by outgassing at contacts with surface waters, and by ground water use need to be quantified to determine the contribution to atmospheric $N_2$O. Contamination of subsurface environment with N $O_3$$^{ }$ and organics has the potential for increasing the contribution to atmospheric $N_2$O by enhancing denitrification .

  • PDF