• Title/Summary/Keyword: uncertainties of measurement data

Search Result 104, Processing Time 0.033 seconds

A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants (원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구)

  • Yu Sung-Sik;Park Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

A Study on Measurement Uncertainty of Insensitive Munitions Tests (둔감탄약 시험의 측정불확도 산출 방안 연구)

  • Kim, Min;Kim, Jong-Myoung;Yang, Seung-Ho;Sun, Tae-Boo
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.533-547
    • /
    • 2017
  • Purpose: This study proposes the main sources of uncertainty and uncertainty analysis of a measurement system of insensitive munitions tests. Methods: We established the mathematical model for calculating measurement uncertainty of insensitive munitions tests, conducted experiments for calculating uncertainties of dynamic sensitivity and overshoot value, and estimated the distributions of uncertainty factors. Results: The measurement uncertainty calculation methods are presented, which include experimental data processing methods for calculating uncertainties of dynamic sensitivity and overshoot value. Conclusion: The measurement of explosion pressure in insensitive munitions tests is an important issue to the reporting test results and classifying reaction types. The more efforts to ensure the reliability of the insensitive munitions tests results are required.

Development of an Investigation Method for Variation Factors of Measurement Processes (측정 프로세스의 변동 요인 조사 방법 개발)

  • Choi, In-Soo;Kang, Chang Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.2
    • /
    • pp.72-81
    • /
    • 2016
  • There can be included a variety of uncertainties in all measurement results whether we can perceive or not on the causes. These uncertainties may end up in lowering the reliability of measurement results and also deteriorate the level of quality. For the purpose, we tried to combine the strengths of measurement uncertainty and measurement system analysis together to present a practical flowchart so as to verify those potential variation factors in general measurement processes. As a case study, we did an experiment and gathered data on the length between two holes of an engine cylinder head which is a core part for vehicles with a coordinate measuring machine and estimated nine uncertainty factors of it. Consequently, it was identified that the four primary factors among the nine which were related to the measurement standard, random errors or spread of the repeat measurements, differences between the coefficients of thermal expansion and the environment especially had been the influence around the laboratory. Since it is impossible to analyze the equipment and appraisal variations respectively through the only measurement uncertainty, we have used the measurement system analysis following the flowchart. Showing the result of being just about 0.5% lower for the appraisal variation, and the equipment variation occupied about 7% for the total Gage R&R. Through this research, we have come to a conclusion that much more detail analysis on variation factors can be possible to be identified in measurement processes by using the developed flowchart which is composed of measurement uncertainty and measurement system analysis. Therefore, we expect engineers who are involved in quality and measurements to utilize this developed method.

Correlations between the Important Physical Properties of Natural Gas (천연가스 주요 물성 간의 상관식)

  • Ha, Youngcheol;Lee, Seongmin;Her, Jaeyoung;Lee, Kangjin;Lee, Seungjun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.599-607
    • /
    • 2009
  • This study was conducted to derive the five correlations which could predict specific gravity(or heating value), compression factor, density, etc., if we know heating value or specific gravity only. To make a sufficient number of raw data for regression, SGERG EOS was modified into equation of heating value. Based on these raw data, five correlations were obtained and the uncertainties of the correlations were evaluated. The results showed that the uncertainties were near 0.1% in most conditions of natural gas and so the correlations could be used in natural gas industry and academic fields.

Studies of process measurement technology for manufacturing advanced nano devices (첨단 나노소자 공정제어용 측정기술 연구)

  • Cho, Yong Jai
    • Vacuum Magazine
    • /
    • v.2 no.3
    • /
    • pp.4-10
    • /
    • 2015
  • We developed a real-time three-polarizer spectroscopic ellipsometer based on a new data acquisition algorithm and a general data reduction (the process of extracting the ellipsometric sample parameters from the Fourier coefficients). The data acquisition algorithm measures Fourier coefficients of radiant flux waveform accurately and precisely. The general data reduction is introduced to represent the analytic functions of the standard uncertainties of the ellipsometric sample parameters, and the extracted theoretical values closely agree with the corresponding experimental data. Our approach can be used for optimization of measurement conditions, instrumentation, simulation, standardization, laboratory accreditation, and metrology.

Measurement of Velocity Disturbance for Robust Seek Control (강인 검색 제어를 위한 속도 외란 측정)

  • 이문노;신진호;김성우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.11
    • /
    • pp.860-867
    • /
    • 2003
  • This paper presents a systematic method measuring a velocity disturbance to design the robust seek loop system of optical disk drives. The velocity disturbance caused by the rotation of a disk has a greater influence on the performance of the seek control loop as the rotational speed increases. Thus, it needs to measure the extent of the velocity disturbance and design the seek control loop based on the measured data. The measurement method of the velocity disturbance is a real-time . method using a measurable velocity and a velocity controller output and is a robust method considering actuator uncertainties. The loop gain adjustment algorithm is introduced to compensate for the actuator uncertainties. The proposed method is implemented by an experimental digital system and is evaluated through an experiment.

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

Uncertainty of Efficiency Equation of Solar Thermal Collectors (태양열 집열기 효율식의 불확도)

  • Lee, Kyoung-Ho;Lee, Soon-Myung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.65.1-65.1
    • /
    • 2010
  • Thermal performance tests of solar thermal collectors include determination of coefficient parameters in an efficiency equation. The parameters can be estimated using regression method to minimize an objective function as sum of differences between measured efficiency data and regressed efficiency equation. However, this conventional approach doesn't consider measurement uncertainties. In this presentation, a method to determine regression parameters in the efficiency equation and uncertainties of the parameters is described with mainly mathematical expressions based on literature reviews. In the method, parameters in the equation for collector efficiency can be determined using regression analysis with a weighting factor in the objective function. The weighting factor can be uncertainties of the differences between measured and fitted efficiencies. To evaluate the approach, performance estimation of a solar collector using the efficiency equation with uncertainties is compared to the result using the conventional efficiency equation by a simulated way for a case in one of previous studies.

  • PDF

Experimental Approach to Equalizing the Orifice Method with the Throughput One for the Measurement of TMP Pumping Speed

  • Lim, J.Y.;Kang, S.B.;Shin, J.H.;Koh, D.Y.;Cheung, W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.18-18
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. With UHV gauges of uncertainties less than 15% and a calculated conductance of the orifice, about 35% of pumping speed uncertainties are experimentally derived in the pressure range of less than $10^{-6}$ mbar. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced an SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-3}$ mbar-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to less than $10^{-6}$ mbar with an uncertainty of 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

  • PDF

Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS (GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kim, Jong-Sang;Kim, Min-Kyoung;Lee, Jae-Il;Suh, Yong-Jun;In, Moon-kyo
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.