• Title/Summary/Keyword: unbalanced model

Search Result 287, Processing Time 0.027 seconds

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter under Line Voltage Unbalance Condition (커패시터 필터를 갖는 3상 다이오드 정류회로의 불형전원에서의 입력전류 특성)

  • 정승기;이동기;박기원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.38-38
    • /
    • 2001
  • The three-phase diode rectifier with capacitive filter is highly sensitive to line voltage unbalance. Because of its inherent nonlinear characteristics, small line voltage unbalance may cause highly unbalanced line current, causing detrimental effects on power quality. This paper presents a theoretical basis on this ′unbalance amplification effect′ and derives an analytical model of line current characteristics under unbalanced line voltage condition for various modes of operation. The results provide a basic guideline for optimal design of a three-phase diode rectifier with capacitive filter that is most commonly used for interfacing various power conversion equipments to power lines.

Methods and Techniques for Variance Component Estimation in Animal Breeding - Review -

  • Lee, C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.3
    • /
    • pp.413-422
    • /
    • 2000
  • In the class of models which include random effects, the variance component estimates are important to obtain accurate predictors and estimators. Variance component estimation is straightforward for balanced data but not for unbalanced data. Since orthogonality among factors is absent in unbalanced data, various methods for variance component estimation are available. REML estimation is the most widely used method in animal breeding because of its attractive statistical properties. Recently, Bayesian approach became feasible through Markov Chain Monte Carlo methods with increasingly powerful computers. Furthermore, advances in variance component estimation with complicated models such as generalized linear mixed models enabled animal breeders to analyze non-normal data.

An Improved Control Method for a DFIG in a Wind Turbine under an Unbalanced Grid Voltage Condition

  • Lee, Sol-Bin;Lee, Kyo-Beum;Lee, Dong-Choon;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.614-622
    • /
    • 2010
  • This paper presents a control method, which reduces the pulsating torque and DC voltage problems of a doubly fed induction generator (DFIG)-based wind turbine system. To reduce the torque and power ripple, a current control scheme consisting of a proportional integral (PI) controller is presented in a positive synchronously rotating reference frame, which is capable of providing precise current control for a rotor-side converter with separated positive and negative components. The power theory can reduce the oscillation of the DC-link voltage in the grid-side converter. In this paper, the generator model is examined, and simulation results are obtained with a 3 kW DFIG-based wind turbine system to verify the proposed control strategy.

Balanced hypothesis testing for interactions of unbalanced case using analysis of means (평균분석을 이용한 교호작용의 균형 검정 방법 불균형 관측치의 경우)

  • 김병천;정강모
    • The Korean Journal of Applied Statistics
    • /
    • v.3 no.1
    • /
    • pp.89-103
    • /
    • 1990
  • An analysis of mean procedure is presented for testing the significance of two factor interactions for unbalanced case. When at least one factor if at only two levels, the technique is the same as that of Ott(1967) and Nelson(1988) except that we have used the critical value by using the Sidak's multiplicative inequality. The technique can be extended to the case in which both factors more than two levels. Tables of critical values g($\alpha ; (p, q) ; v$) are given for $\alpha$=0.05 and 0.01 ; (p, q) combinations satisfying $3 \leq p \leq q \leq 5$ ; and various degrees of freedom v. We present and prove the formula of the variance of the interactions for the n-way model.

  • PDF

Dynamic Analysis of an Optical Disk Drive with Dynamic Vibration Absorber (동흡진기를 채용한 광 디스크 드라이브의 동적 해석)

  • 김남웅;김국원;황효균;김동규;이진우;김외열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.867-870
    • /
    • 2002
  • In high-speed optical disk drive, the excitation caused by rotation of a mass-unbalanced disk is a major source of vibration. The vibration can be a disturbance to the servo system, which is sufficient to cause severe failures in the reading and writing process. The vibration also causes users to feel unpleasantness. The vibration reduction is therefore essential for the reliable operation of optical disk drive. One of the approaches to reduce the vibration is a dynamic vibration absorber (DVA). In this paper, we analyze the dynamic behavior of $DVD\pmRW$ combo drive system with DVA through 12_dof rigid multi-body dynamic model. The effective location and the optimal frequency ratio are obtained from the analysis.

  • PDF

Study on Improving the Performances of Transformer and Convertor Switching Used for the High-Speed EMU (동력분산형 고속철도의 변압기 및 컨버터 스위칭 성능 개선 연구)

  • Park, Byoung-Gun;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1182-1187
    • /
    • 2008
  • In this research, studied were performance improvements of the power conversion system for the high speed EMU. The object of this research is separated into two parts ; the one is the analysis of the designed transformer and the other is the switching improvement of a parallel PWM converter. The multi-outputs of a transformer must be balanced. However, the output of transformer is interfered and unbalanced in practical operation. To solve these problems, the electromagnetic analyzing model of a transformer is used to minimize the output interference. Also, the improvement of converter switching can reduce the unbalanced output and harmonics.

  • PDF

Ranking Dispatching Rules in the Job Shop with Unbalanced Machine Workloads (설비 작업부하가 불균형한 Job Shop에서 할당규칙의 순위)

  • 배상윤
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.50
    • /
    • pp.161-170
    • /
    • 1999
  • This paper evaluates forty different dispatching rules with respect to twenty different performance measures of job shop scheduling under seven levels of workload imbalance. Computer simulation is used as a tool to determine rankings of the dispatching rules for a given workload imbalance. The experiments results show rankings of dispatching rules are different in the job shop with unbalanced machine workloads. As variations of workload imbalance increase from 7% to 78%, the performance of dispatching rules is gradually deteriorated in measure related to completion time and due date. These results guide scheduling practitioners not only to choosing dispatching rules but also to developing the model of facility investment for workload balance, when there are different levels of workload imbalance.

  • PDF

Dynamic Behavior Analysis of an Eccentric Rotor with Unbalanced Magnetic Forces in BLDC Motors (BLDC 전동기의 전자기적 불평형력을 고려한 편심 회전자의 동적 거동 해석)

  • Kim, Tae-Jong;Hwang, Sang-Mun;Park, No-Gil
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.604-610
    • /
    • 1999
  • Vibration of a rotor-bearing system driven by an electric motor is a coupled phenomenon between mechanical characteristics and magnetic origins through the air-gap. With the advent of new high-energy magnets together with high precision motor applications, magnetic sources of vibration are becoming more serious. This paper investigates the transient whirl responses of a rotor system with purely mechanical origins and compares it with that of magnetically coupled origins. A perturbation method is applied to model the magnetic field associated with rotor eccentricity. Electromagnetic forces are obtained by the Maxwell stress method, which utilizes the analytical expression of radial flux density distribution. The FEM was applied to a rotor-motor system to illustrate magnetically coupled effects in rotor dynamics. Results show that magnetically coupled sources significantly affect the vibration of the rotor-motor system.

  • PDF

Design and Characteristic Analysis of MC-LOA taking into account the Magnetic Circuit unequivalence (자기회로의 불평형을 고려한 MC-LOA의 설계 및 특성 해석)

  • Eum, Sang-Joon;Kim, Duk-Hyun;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.145-147
    • /
    • 1999
  • A voice type Moving Coil Linear Oscillatory Actuator(MC-LOA) has unbalanced magnetic circuit structure. Its asymmetric magnetic flux distribution along the mover directions causes shifting of displacement center to one side. Therefore, this paper analyzes both thrust and displacement characteristics and settles the unbalanced flux problem by performing shape optimization. The propriety of the improved design model has been verified by dynamic analysis based on the coupling of kinetic and electric equations.

  • PDF

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter Under Line Voltage Unbalance Condition (커패시터 필터를 갖는 3상 다이오드 정류회로의 불평형전원에서의 입력전류 특성)

  • Lee Dong-Gei;Park Gei won;Jung Seong Gei
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.569-575
    • /
    • 2001
  • The three-phase diode rectifier with capacitive Inter is highly sensitive to line voltage unbalance. Because of its inherent nonlinear characteristics small line voltage unbalance may cause highly unbalanced line current causing detrimental effects on power quality. This paper presents a theoretical basis on this 'unbalance amplification effect' and derives an analytical model of line current characteristics under unbalanced line voltage condition for various modes of operation. The results provide a basic and important guideline for optimal design of a three-phase diode rectifier with capacitive filter that is most commonly used for interfacing various power conversion equipments to power lines.

  • PDF