• 제목/요약/키워드: ultrasound transducer

검색결과 197건 처리시간 0.028초

Ultrasonic Transducers for Medical Volumetric Imaging

  • Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권3E호
    • /
    • pp.111-118
    • /
    • 2010
  • Three-dimensional ultrasound imaging is a new, exciting technology that allows physicians to use ultrasound to view pathology as a volume, thereby enhancing comprehension of patient anatomy. In this paper, a brief history of the 3-D ultrasound imaging is described in accordance with the development of transducer technology. Then, two representative types of 3-D imaging transducers are reviewed with description of the concept and operation principle of each type: mechanical transducer and matrix array transducer. The mechanical transducer is detailed into free-hand scanning and sequential scanning types. Advantages of each transducer over the other and the technical issues for further performance enhancement are also presented.

속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합 (Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging)

  • 김영훈;박관규
    • 비파괴검사학회지
    • /
    • 제36권1호
    • /
    • pp.27-34
    • /
    • 2016
  • 본 논문은 초음파를 이용한 단층촬영(ultrasound computed tomography, UCT)을 위해 사용되는 영상 복원 방식에서 실제 사용되는 초음파 트랜스듀서의 조합에 따른 영항을 다루었다. 촬영 대상의 속도 분포를 구하기 위해서 라돈 변환(radon transform)을 사용하였으며, 음향 임피던스의 영상화를 위하여, 시간지연(delay and sum)방식을 사용하였다. 음향 임피던스 영상의 경우 속도 분포 영상에 의해 보정하여 더 정확한 영상을 복원하였다. 매질의 특성에 따른 감쇠, 굴절 및 반사를 고려한 초음파 시뮬레이터로 128개의 환형 트랜스듀서 어레이를 구현하였으며, 5 MHz의 중심주파수로, 5 cm의 인체조직 영상을 구현하였다. 실제 구현을 위한 최적의 트랜스듀서 조합을 찾기 위해, 점 진원(point source), 평면 트랜스듀서(flat transducer), 집속 트랜스듀서(focused transducer)를 이용해서 속도 분포에 대한 영상과 음향 임피던스 영상을 구현하여 비교하였다. 또한 시뮬레이션 상에서는 송신 및 수신 트랜스듀서가 모두 점 트랜스듀서인 경우가 가장 좋은 결과를 보여주었으나, 실제 구현을 고려하면 송신은 평면 트랜스듀서가 수신은 점 트랜스듀서로 하는 조합이 가장 현실적으로 좋은 결과를 보여준다.

초음파검사실 감염관리 인식에 대한 연구 (A Study on the Perception of Infection Control in Ultrasound Diagnostic Room)

  • 안현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.367-374
    • /
    • 2020
  • The purpose of this study is to understand the infection prevention system and infection management perception of Ultrasound diagnostic room in medical institutions by sonographer's in general practitioner, semi and general hospitals. As a research method, a statistical analysis was conducted by surveying a total of 20 items in four category to determine the infection perception of sonographer's according to gender, age, working institution, and working period. As a result of infection awareness, males were in the ultrasound gel management category, women were in the transducer management category, all age groups were in the transducer management system category, and the General Practitioner, semi and general hospitals. were in the transducer management system category, and general hospitals showed a high degree of infection awareness in the category of disinfection and sterilization, and in the category of transducer management in the entire working period. In the results of the analysis of the correlation between the sub-factors of the perception of infection control in the Ultrasound diagnostic room the degree of correlation between each category showed a middle degree correlation(r>0.5) and a significant difference by category(p<.01). In conclusion, the prevention of infection in the ultrasound diagnostic room, which sonographer's firms think, was found to be the most efficient ultrasound diagnostic room infection control to implement transducer and gel management in accordance with the principles of disinfection and sterilization.

멀티주파수 초음파를 사용하는 피부 치료기기 트랜스듀서의 효율적인 주파수 제어 연구 (A Study on Efficient Frequency Control of Transducer for Skin Treatment Using Multi-Frequency Ultrasound)

  • 박종철;김민성
    • 한국멀티미디어학회논문지
    • /
    • 제25권8호
    • /
    • pp.1038-1048
    • /
    • 2022
  • Ultrasound is one of the effective methods for skin treatment. The skin penetration depth of the ultrasound depends on the ultrasonic frequency, that is, when the ultrasonic frequency is high, the depth is shallow. We have developed a transducer which can generate effectively 3 different ultrasonic frequencies removing interference between 3 types of frequencies according to impedance matching technology. The generated powers of transducer are 40.67W at 3.MHz, 17.46W at 11.7 MHz, and 14.79W at 21.5 MHz. The signal interference between the three frequencies is designed so that they do not interfere with each other by separating the signals using the SPDT (Single Pole, Double Throw) switch. The developed hybrid ultrasound transducer can be applied in skin care or skin treatment and beauty therapy.

Development of an Impedance Matching Layer in an Ultrasound Transducer with Gradient Properties

  • Jeong, Jihoon
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.374-379
    • /
    • 2018
  • The piezocomposite transducer is widely used because it is highly efficient in transforming electric energy into mechanical energy, and its frequency range is broader than that of other types of ultrasound transducers. A general piezocomposite transducer is composed of an acoustic lens, impedance matching layers, piezoelectric materials, and backing layers. When an input voltage is applied to a piezoelectric material as an active material, it generates sound waves while vibrating. At that time, an impedance matching layer helps the sound waves to propagate forward while reducing the impedance mismatch that may occur at the interface between the active material and its front material. The impedance mismatch has a negative effect on the signal of an ultrasound transducer; thus, it is important to design a matching layer to overcome the issue. In this study, an optimized feature of a matching layer with gradient properties is studied. An objective function is defined to minimize both the average and the deviation of the reflection coefficients that are functions of the frequencies. As a result, an improvement in the signal characteristics with respect to the sensitivity and bandwidth is reported.

신경회로망과 다소자 초음파 트랜스듀스에 의한 수중물체의 화상화 (Object imaging in the water by neural network and multi-element ultrasound transducer)

  • 김응규
    • 전자공학회논문지S
    • /
    • 제35S권1호
    • /
    • pp.80-87
    • /
    • 1998
  • In this study, a multi-element ultrasound transducer has been developed aiming at basic experiment of three-dimension endovascular ultrasound endscopy for clinical diagnos, and experimental results of two-dimensional object imaging in the water are presented by the ultrasound tranducer and neural network. Each ultrasound echo received by thirty-six angular transducer elements is inputed to the eural network, and then backpropagation is used as a learning algorithm. A three-layer artificial neural network is used for learning and imaging of targetw placed in front of the transducer. The object shape of imaging is restricted to rectangular shapes by considering experimental restraint conditions. As a result, rough visualization can be realized even for objects with unlearned shapes through the training by primitive patterns of a various sized rectangular targets.

  • PDF

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석 (Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model)

  • 최호선
    • 정보학연구
    • /
    • 제8권1호
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

초점 초음파 측정기로 측정한 광음향 신호의 광 흡수계수에 대한 비선형성 (Photoacoustic Nonlinearity to Absorption Coefficients in Photoacoustic Imaging with Focused Ultrasound Transducers)

  • 강동열
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.158-165
    • /
    • 2017
  • 광 흡수체로부터 측정되는 광음향 신호의 크기가 광 흡수계수 값의 증가에 따라 증가하다가 포화되는 광음향 비선형성에 대한 기존의 분석에서는 초음파 측정기의 물리적 형태를 고려하지 않았다. 이 논문에서는 초음파 측정기의 구면 초점 형태가 광음향 비선형성에 미치는 영향을 분석하였다. 구면 초점 초음파 측정기의 공간 필터링에 의한 광음향 공명 현상을 고려하고 기존의 광음향 비선형성에 대한 연구 방법을 보완하여 구면 초점 초음파 측정기로 측정한 광음향 신호에 대한 해석식을 이론적으로 유도하였다. 이 해석식에 의한 결과는 광음향 신호가 특정한 광 흡수계수 값에서 최대값을 나타내고 최대값 이후로는 광 흡수계수 값의 증가에 따라 오히려 감소함을 보였다. 주파수 영역에서 구면 초점 초음파 측정기에 의해 측정된 광음향 신호의 공명 스펙트럼과 초음파 측정기의 주파수 전달 함수를 비교하여 이 기존의 통념과는 다른 특징을 보이는 광음향 비선형성을 이해하였다. 또한, 이 주파수 영역에서의 물리적 해석으로 인해 광음향을 발생시키는 광 흡수체 내부의 광 조도 형태도 광음향 비선형성에 영향을 미친다는 것을 알 수 있었다.

2D Sparse Array Transducer Optimization for 3D Ultrasound Imaging

  • Choi, Jae Hoon;Park, Kwan Kyu
    • 비파괴검사학회지
    • /
    • 제34권6호
    • /
    • pp.441-446
    • /
    • 2014
  • A 3D ultrasound image is desired in many medical examinations. However, the implementation of a 2D array, which is needed for a 3D image, is challenging with respect to fabrication, interconnection and cabling. A 2D sparse array, which needs fewer elements than a dense array, is a realistic way to achieve 3D images. Because the number of ways the elements can be placed in an array is extremely large, a method for optimizing the array configuration is needed. Previous research placed the target point far from the transducer array, making it impossible to optimize the array in the operating range. In our study, we focused on optimizing a 2D sparse array transducer for 3D imaging by using a simulated annealing method. We compared the far-field optimization method with the near-field optimization method by analyzing a point-spread function (PSF). The resolution of the optimized sparse array is comparable to that of the dense array.