• 제목/요약/키워드: ultrasound technology

검색결과 490건 처리시간 0.027초

Ultrasonic Transducers for Medical Volumetric Imaging

  • Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권3E호
    • /
    • pp.111-118
    • /
    • 2010
  • Three-dimensional ultrasound imaging is a new, exciting technology that allows physicians to use ultrasound to view pathology as a volume, thereby enhancing comprehension of patient anatomy. In this paper, a brief history of the 3-D ultrasound imaging is described in accordance with the development of transducer technology. Then, two representative types of 3-D imaging transducers are reviewed with description of the concept and operation principle of each type: mechanical transducer and matrix array transducer. The mechanical transducer is detailed into free-hand scanning and sequential scanning types. Advantages of each transducer over the other and the technical issues for further performance enhancement are also presented.

Effects of Combination Treatments of Nisin and High-intensity Ultrasound with High Pressure on the Functional Properties of Liquid Whole Egg

  • Lee, Dong-Un
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1511-1514
    • /
    • 2009
  • Liquid whole egg (LWE) was subjected to high hydrostatic pressure (HHP), a consecutive combination of nisin and HHP (nisin-HHP), or a consecutive combination of ultrasound and HHP (ultrasound-HHP), and functional properties of processed LWE were compared to those of raw LWE. Little changes in foaming and emulsifying properties were observed by the application of HHP alone and the combined process of nisin and HHP. In contrast, ultrasound-HHP combination resulted in significant changes in color, foaming, and emulsifying properties. The maintenance of functional properties after HHP treatment agreed with expectation, because the HHP processing condition had been selected where minimal rheological changes had occurred.

Effects of Water or Brine Immersion Thawing Combined with Ultrasound on Quality Attributes of Frozen Pork Loin

  • Hong, Geun-Pyo;Chun, Ji-Yeon;Jo, Yeon-Ji;Choi, Mi-Jung
    • 한국축산식품학회지
    • /
    • 제34권1호
    • /
    • pp.115-121
    • /
    • 2014
  • This study explored the effects of water or brine (2% NaCl, w/v) immersion thawing combined with ultrasound treatment (40 kHz, 150 W) on the quality characteristics of pork. Ultrasound treatment of pork was conducted in two cold media (at $4^{\circ}C$), water and 2% (w/v) brine, respectively. Because the ultrasound treatment caused temperature increase in the media from $4^{\circ}C$ to $16^{\circ}C$, the qualities of pork thawed by ultrasound were compared with those thawed by immersion either in water or brine where the temperature was being maintained at either $4^{\circ}C$ (low temperature control) or $17^{\circ}C$ (high temperature control). The ultrasound treatment resulted in rapid thawing of pork where the thawing rate was similar to those thawed in the $17^{\circ}C$ media. For quality characteristics, ultrasound-treated pork in brine had an advantage of less cooking losses when comparing to the control. In particular, ultrasound treatment in brine exhibited the lowest shear force (or highest tenderness) among the freezing/thawing treatments. Although the ultrasound processing in brine caused discoloration of the pork, this thawing technique had potential to be applied as a commercial thawing technology for frozen foods.

초음파 영상진단장치 (A Diagnostic Ultrasound Imaging System)

  • 이승우
    • 비파괴검사학회지
    • /
    • 제19권3호
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구 (A Study on the Reflectivity according to the Material of Biopsy Gun Needle Used in Ultrasound Biopsy)

  • 김훈;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.97-105
    • /
    • 2024
  • The examination needle used in ultrasound biopsy is a medical device used to determine whether there is an abnormality in the tissue. Typically, stainless steel is the standard material used for such needles; however, this study wanted to identify a material that could better enhance sound compared to traditional stainless steel. In this study, six types of needle materials available with the biopsy gun were inserted into pork and ultrasound images according to the curved probe and linear probe were evaluated using ultrasound equipment. The findings revealed significant improvements in ultrasound acoustic enhancement with alternative materials compared to stainless steel (p<0.05). The results regarding the depth of each ultrasound image using the curved probe showed that tungsten and brass had high sound enhancement(p<0.05), while with the linear probe, sound enhancement was high in brass, pla, aluminum, and copper(p<0.05). Due to these results, the previously used stainless needle showed lower ultrasound acoustic enhancement than the five types of materials being compared. Consequently, the outcomes of this study provide valuable insights for the development of new needle technologies aimed at minimizing patient risks and improving diagnostic accuracy.

Inhibitory Effects of Ultrasound in Combination with Ascorbic Acid on Browning and Polyphenol Oxidase Activity of Fresh-cut Apples

  • Jang, Ji-Hyun;Kim, Sang-Tae;Moon, Kwang-Deog
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1417-1422
    • /
    • 2009
  • This study was conducted to investigate the effect of ultrasound with ascorbic acid on the quality of fresh-cut apples. Prepared apple cubes were dipped in distilled water (US) or in 1% ascorbic acid solution (AS), both were treated with ultrasound at 40 kHz, while the other sample was just dipped in 1% ascorbic acid solution for 1 min (AA). All samples were stored at $4^{\circ}C$ for 12 days. AS treatment had an effect on apple cube color as indicated by its significantly higher L values and lower ${\Delta}E$ value whereas AA- and US-treated samples showed a considerable browning. Higher inhibition rate on browning and polyphenol oxidase (PPO) activity of 46 and 98%, respectively, were observed after AS treatment. The highest total phenolic content of AS-treated samples was shown during whole storage periods. This investigation revealed that the use of ultrasound in combination with ascorbic acid had a positive effect on quality maintaining of fresh-cut apples.

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

Low-frequency Ultrasound Enhanced Transdermal Drug Delivery Across Rat Skin

  • 이화진;김종율;박진남;신영희
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권6호
    • /
    • pp.365-368
    • /
    • 2007
  • The primary aim of this study was to investigate the enhancement effect of low-frequency ultrasound on skin permeation. In vitro permeation experiments were performed using Franz modified diffusion cells with ketoprofen as model drug. The effect of various ultrasound factors-ultrasound application mode (continuous mode and discontinuous mode), ultrasound intensity (0.26 $W/cm^2$, and 0.29 $W/cm^2$) and duty cycle (3%, 16%, 50%, and 83%) were studied. The highest permeation was observed at 0.29 $W/cm^2$ intensity, 50% duty cycle, and discontinuous mode. The result suggested the feasibility of low frequency ultrasound application for the phonophoretic transdermal drug delivery system.

대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석 (Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model)

  • 최호선
    • 정보학연구
    • /
    • 제8권1호
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

ICR 마우스의 태아(胎兒)에 대(對)한 방사선(放射線)과 초음파(超音波)의 공동효과(共同效果)에 관한 실험적(實驗的) 검토(檢討) (Combined Effects of Radiation and Ultrasound on Embryonic Development in Mice)

  • 구연화
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권2호
    • /
    • pp.37-44
    • /
    • 1991
  • The combined effect of radiation and ultrasound has been studied in mouse embryos. Radiation and/or ultrasound were adminstered to ICR mice on day 8 of gestation. Intrauterine death, gross malformation, and fetal body weight were selected as indicators of effects. Does of whole-body ${\gamma}-irradiation$ were 0.5 to 2.5 Gy and those of ultrasound were $0.5\;W/cm^2$ to $3\;W/cm^2$. Intrautrine mortality increased with increasing radiation dose ; this trend was more remarkable in combination with ultrasound. Gross malformations such as exencephaly and anophthalmia/microphthalmia appeared frequently in the fetuses treated with both radiation and ultrasound. Decreased fetal weight was observed even in mice treated with 1.5 Gy of radiation or $1\;W/cm^2$ of ultrasound. There was a linear relationship between dose and reduction of fetal weight. The fetal weight was sensitive, precise and easy-to-handle indicator for the effects of growth retardation. Intrauterine mortality and frequencies of exencephaly and anophthalmia/microphthalmia were higher than the sum of those induced by radiation and by ultrasound. The results indicatied that the combined action of radiation and ultrasound on intrauterine death and malformations was synergistic.

  • PDF