Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
Asian Pacific Journal of Cancer Prevention
/
v.16
no.18
/
pp.8619-8623
/
2016
Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.
Typically, photoacoustic images are obtained in water or gelatin because the impedance of these mediums is similar to that of the human body. However, these acoustic mediums can have an additional mass effect that changes the resonance frequency of the transducer. The acoustic radiation impedance in air is negligible because it is very small compared to that of the transducer. However, the high acoustic impedance of mediums such as the human body and water is quite large compared to that of air, making it difficult to ignore. Specifically, in a case where the equivalent mass is very small, such as with a micro-machined ultrasound transducer, the additional mass effects of the acoustic medium should be considered for an accurate resonance frequency design. In this study, a piezoelectric micro-machined ultrasonic transducer (pMUT) was designed to have a resonance frequency of 10 MHz in the acoustic medium of water, which has similar impedance as the human body. At that time, the resonance frequency of the pMUT in air was calculated at 15.2 MHz. When measuring the center displacement of the manufactured pMUT using a laser vibrometer, the resonance frequencies were measured as 14.3-15.1 MHz, which is consistent with the finite element method (FEM) simulation results. Finally, photoacoustic images of human hair samples were successfully obtained using the fabricated pMUT.
KIPS Transactions on Software and Data Engineering
/
v.3
no.6
/
pp.231-236
/
2014
The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.
Kim, Seong-Heon;Kim, Hye-Young;Im, Young-Tak;Nam, Sang-Ook;Kim, Young-Mi
Clinical and Experimental Pediatrics
/
v.53
no.4
/
pp.603-606
/
2010
Paraneoplastic limbic encephalitis, a remote effect of cancer without nervous system metastasis, is rare, especially in childhood. Here, we report a case of paraneoplastic limbic encephalitis associated with an ovarian mature teratoma in an adolescent girl. The 15-year-old girl developed neuropsychiatric symptoms, memory loss, seizures, and unconsciousness. Cerebrospinal fluid analysis and brain magnetic resonance imaging (MRI) findings were normal, while single photon emission computed tomography imaging showed hypoperfusion in both temporal lobes. Ultrasound and MRI of the abdomen revealed a left ovarian cystic mass. The patient experienced a significant recovery of cognitive function after surgical resection of the tumor, which was pathologically identified as a mature ovarian teratoma, and treatment with intravenous immunoglobulin.
License system of radiologic technologists has been started since 1965 in Korea. This study is to explore directions on radiotechnologists' license system classified by subspecialty. For this purpose, the authors surveyed on radiotechnologists' license system classified by subspecialty, with the subject related to radiotechnologic societies. Additionally, data on qualification and license system associated with medical and health care field were collected. The results are as follows. 1. The main body for subspecialty system for radiologic technologists should be the Korea Radiologic Technologists Association and the Association should maintain a close cooperation with radiotechnologic societies. 2. A radiologic technologist should be a basic role once they pass the license examination. In addition, they can get a special qualification by subspecialty in radiologic technology. 3. Radiotechnologists' license system classified by subspecialty will be keep priorities in order and done systematically. Execution order is as follows ; This study proposes that radiotechnologists responsible for ultrasonography, computed tomography(CT), magnetic resonance imaging(MRI) and security management be started for the first stage. For the second stage, radiotechnologists for mammography, angio-cardiography, digital imaging, maxillo-facial and dental radiography, nuclear medicine, radio-therapeutic field should be in force. 4. Professional education course(basic and intensive) and clinical training program have to be made for the eligibility of radiotechnologists' license system classified by subspecialty. 5. Eligibility system of radiotechnologists' license system classified by subspecialty(non-government or government) has to be made. Further more, inquiry commission to investigate eligibility for radiotechnologists' license system should be established.
Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
Physical Therapy Korea
/
v.18
no.1
/
pp.37-46
/
2011
The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.
Background: Bridging exercises are used to enhance the functional stability of the lumbopelvic region in clinical settings. Although most of the studies on bridging exercises have compared the complete activation of the trunk muscles, some recent studies have examined the functional stability of the trunk and the lumbopelvic region and assessed the appropriate recruitment of the local and global muscles during different task levels. Objects: The purpose of this study was to investigate the changes in muscle thickness in the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles during a common bridging exercise on an unstable surface and to determine whether these changes differ based on the surface used. Methods: Twenty-five healthy young adults (8 males, 17 females) were recruited. The subjects were randomly assigned to either the exercise progression with a sling bridge group or the ball bridging exercise progression group, each with three stages of increasing difficulty. Each position was measured three times with an ultrasonic diagnostic imaging system, and the mean values were recorded for analysis. Results: No significant differences were observed between the TrA, IO, or EO muscle thickness ratios between the sling and ball exercise groups (p > 0.05). There were also no significant differences in the EO muscle thickness ratios between the tasks irrespective of whether the sling or ball was used. However, the TrA and IO thickness ratios in both groups were significantly greater during stages 2 and 3 compared to stage 1. Conclusion: The results suggest that the use of slings and balls during bridging exercises is effective in activating the deep abdominal muscles.
Objectives: The purpose of this study is to investigate the characteristics, validity, and reliability of non-radiological assessment tools of scoliosis that have been studied so far. Methods: Electronic databases including Pubmed, Cochrane Library, CNKI, Science On, RISS, OASIS were searched by keywords including 'scoliosis assessment', 'scoliosis screening', 'physical examination', 'functional measurement', 'photography', and 'smartphone'. Results: 32 articles using radiation-free assessments were identified from 1,011 records. The mostly used non-radiological methods were Surface topography, Scoliometer, Ultrasound, Digital Infrared Thermal Imaging, and Photography. The other methods were Gait analysis, 3D depth sensor imaging, and Low intensity electromagnetic scan. Conclusions: It was found that non-radiological assessment tools might reduce the number of radiographs taken in scoliosis patients. To increase the reliability and validity, further research on the measurement tools of scoliosis will be needed.
Background: Latissimus dorsi (LD) tendon transfer is used as a treatment option for massive irreparable posterosuperior rotator cuff tears, and recently, an arthroscopic-assisted technique was introduced. This study was undertaken to evaluate the clinical and radiological outcomes of arthroscopic-assisted LD tendon transfer for the management of irreparable rotator cuff tears in active middle-aged patients. Methods: The records of five patients (two males) with irreparable tears involving the supraspinatus and infraspinatus tendons managed by arthroscopic-assisted LD tendon transfer were retrospectively reviewed. Clinical outcomes were assessed using the visual analogue scale (VAS) pain scale, American Shoulder and Elbow Surgeon's (ASES) scores, the University of California Los Angeles (UCLA) scale, and ranges of motion. Postoperative integrities of transferred tendon were evaluated by magnetic resonance imaging in 4 patients and by ultrasound in one. Results: Mean patient age was 55 years (range, 48-61 years), and mean follow-up period was 20 months (range, 12.0-27.2 months). Mean VAS score significantly improved from $6.6{\pm}2.6$ preoperatively to $1.8{\pm}2.5$ postoperatively (p=0.009), mean ASES score increased from $67.6{\pm}9.2$ to $84.6{\pm}15.1$, and mean UCLA score from $18.0{\pm}1.4$ to $28.8{\pm}8.5$ (all p<0.001). Postoperative imaging of the transferred LD tendon showed intact repair in 4 patients. The remaining patient experienced LD transfer rupture and a poor outcome. Conclusions: Arthroscopic-assisted LD tendon transfer improved shoulder pain and function in patients with massive, irreparable rotator cuff tears, and may be an option for this condition, especially in physically active patients.
A 3-year-old, 20.6 kg, neutered male German Shepherd dog was referred to Kyungpook National University Veterinary Medicine Teaching Hospital. Clinical examination revealed chronic diarrhea for 6 weeks and a non-tender, distended abdomen without lethargy, anorexia, and vomiting. Diarrhea was watery and had a waxing and waning course despite symptomatic treatment. A complete blood count identified mild leukocytosis and mild anemia. Serum biochemistry analysis showed elevated alanine aminotransferase and aspartate aminotransferase levels, and mild hypoalbuminemia. Abdominal ultrasound examination revealed mixed echogenicity with absent blood flow at the caudate process of the caudate liver lobe and a small amount of ascites. Computed tomography revealed torsion of the caudate process of the caudate liver lobe and spleen and gas dilatation of the intestine. After establishing a diagnosis of organ torsion on imaging, we deemed the condition an emergency and immediately performed surgery. Given that laparotomy confirmed organ torsion, liver lobectomy, total splenectomy, and prophylactic gastropexy were conducted. The patient was discharged 11 days after surgery without complications. In general, liver lobe torsion and splenic torsion are uncommon in dogs and present with nonspecific clinical signs, such as abdominal pain, lethargy, anorexia, and vomiting. In the current case, torsion of the caudate liver lobe and spleen occurred without other clinical signs except for a distended abdomen. Moreover, no reports in dogs have demonstrated the simultaneous occurrence of both diseases.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.