• Title/Summary/Keyword: ultrasonic washing

Search Result 47, Processing Time 0.024 seconds

A Study on Remanufacturing of Deactivated Commercial Diesel Oxidation Catalyst by CVS-75 mode in Light Duty Diesel Engine (비활성화된 상용 디젤 산화 촉매의 소형 디젤 기관에서 CVS-75 모드를 이용한 재제조에 관한 연구)

  • Lee, Chang-Hee;Park, Hea-Kyung
    • Journal of Powder Materials
    • /
    • v.18 no.6
    • /
    • pp.517-525
    • /
    • 2011
  • In this study, the used DOCs, which could remove the air pollutants such as CO and HC in the exhaust gas from diesel vehicle, were remanufactured by various conditions. Their catalytic performances and characterization were also investigated. The remanufacturing process of the deactivated DOCs includes high temperature cleaning of incineration, ultrasonic cleaning for washing with acid/base solutions to remove deactivating materials deposited to the surface of the catalysts, and active component reimpregnation for reactivating catalytic activity of them. The catalytic performance tests of the remanufactured DOCs were carried out by the diesel engine dynamo systems and chassi dynamo systems in CVS-75 mode. All prepared catalysts were characterized by the optical microscopes, SEM, EDX, porosimeter and BET to investigate correlations between catalytic reactivity and surface characteristics of them. The remanufactured DOCs at various conditions showed the improved catalytic performances reaching to 90% of fresh DOC, which is attributed to remove the deactivating materials from the surface of the used DOC through the analysis of catalytic performance test and their characterization.

Effect of Pyrolysis temperature on TiO2 Nanoparticles Synthesized by a Salt-assisted Ultrasonic Spray Pyrolysis Process (염 보조 초음파 분무 열분해 공정으로 합성된 TiO2 나노입자의 특성에 열분해 온도가 미치는 영향)

  • Yoo, Jae-Hyun;Ji, Myeong-Jun;Park, Woo-Young;Lee, Young-In
    • Journal of Powder Materials
    • /
    • v.26 no.3
    • /
    • pp.237-242
    • /
    • 2019
  • In this study, ultrasonic spray pyrolysis combined with salt-assisted decomposition, a process that adds sodium nitrate ($NaNO_3$) into a titanium precursor solution, is used to synthesize nanosized titanium dioxide ($TiO_2$) particles. The added $NaNO_3$ prevents the agglomeration of the primary nanoparticles in the pyrolysis process. The nanoparticles are obtained after a washing process, removing $NaNO_3$ and NaF from the secondary particles, which consist of the salts and $TiO_2$ nanoparticles. The effects of pyrolysis temperature on the size, crystallographic characteristics, and bandgap energy of the synthesized nanoparticles are systematically investigated. The synthesized $TiO_2$ nanoparticles have a size of approximately 2-10 nm a bandgap energy of 3.1-3.25 eV, depending on the synthetic temperature. These differences in properties affect the photocatalytic activities of the synthesized $TiO_2$ nanoparticles.

Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography

  • Katheng, Awutsadaporn;Kanazawa, Manabu;Komagamine, Yuriko;Iwaki, Maiko;Namano, Sahaprom;Minakuchi, Shunsuke
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.45-55
    • /
    • 2022
  • PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.

Analysis of contamination characteristics of filter cloth in filter press by repeated dehydration of organic sludge and evaluation of ultrasonic cleaning application (유기성 슬러지 반복 탈수에 의한 필터프레스 여과포 오염 특성 분석 및 초음파 세척 적용 평가)

  • Eunju Kim;Cheol-Jin Jeong;Kyung Woo Kim;Tae Gyu Song;Seong Kuk Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.2
    • /
    • pp.15-25
    • /
    • 2024
  • In this study, the regeneration effect of pressurized water and ultrasonic cleaning was investigated for contaminated filter cloth from the sewage sludge filter press process. For this purpose, contaminated filter cloth was collected from a 3-ton sewage sludge hydrothermal carbon treatment filter press. First, the contamination characteristics were analyzed. According to the location of the filter cloth, air permeability and unit mass were measured, and compared with the values of a new filter cloth. Next, the results were mapped over the entire area to evaluate the contamination characteristics. Finally, pressure cleaning at 3 bar and ultrasound at frequencies of 34, 76, 120, and 168 kHz were performed on the contaminated filter cloth. In addition, the cleaning efficiency was evaluated by 3 levels of contamination degree. As a result, pore contamination occurred mainly at the bottom and both sides of the filter cloth, where the filter material was continuously injected and compressed. Surface contamination appeared evenly over the entire area. As a result of washing, air permeability increased by 1.3-3.1%p and contaminant removal was by 2.7-4.4% under pressure. In ultrasonic cleaning, air permeability increased by 12.5-61.5%p and contaminants were removed by 2.7-29.2%. In ultrasonic cleaning the lower the frequency, the higher air permeability and contaminant removal rate. Also, The higher pore contamination level, the better the air permeability improvement and contaminant removal.

Infection control among dental hygienists according to infection control education experiences (치과위생사의 감염관리 교육경험에 따른 감염관리 실태)

  • Kim, Ji-Hyun;Kim, Jin-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.4
    • /
    • pp.547-556
    • /
    • 2011
  • Objectives : The purpose of this study was to examine the relationship between the infection control education experiences of dental hygienists and the state of their infection control. Methods : The subjects in this study were the dental hygienists who worked in Seoul. The relationship of their infection control education experiences to their gender, marital status, academic credential, workplace, length of service, infection control implementation, experience of being exposed to infection, way of coping with it, hand washing, use of personal protection devices and equipment management was analyzed. Results : It is found that the variable to affect the state of infection control was educational experiences about handpiece water pipe management, ultrasonic scaler water pipe management and three-way syringe water pipe management. Conclusions : Dental hygienists who are one of major dental personnels should receive systematic education on infection control to acquire accurate knowledge to ensure the successful prevention of cross infection.

Effect of Surface Sterilization on Quality of Vacuum Packaged Fresh-cut Deodeok (Codonopsis lanceolata) during Storage (표면살균수 처리 후 진공포장된 신선편이 더덕의 저장 중 품질특성 변화)

  • Choi, Duck-Joo;Lee, Yun-Jung;Kim, Youn-Kyeong;Kim, Mun-Ho;Choi, So-Rye;Cha, Hwan-Soo;Park, Hyung-Woo;Youn, Aye-Ree
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.18 no.1_2
    • /
    • pp.39-44
    • /
    • 2012
  • This study investigated the changes in the quality of minimally processed sliced Deodeok (Codonopsis lanceolata) during storage at $7^{\circ}C$ in relation to vacuum packing using PE film after the various surface washing treatments. The surface washing treatments resulted in approximately 1~2 log CFU/g reduction of microbial load in the early storage day. After 20 days, the weight loss rate, deterioration rate, hardness, color, total microorganism levels and the coliform count of deodeok washed by ultrasonic wave water was deteriorated rapidly like the control. When measured by the fresh-cut deodeok surface using the video microscope system, washing with chlorine water and electrolyzed water didn't seem to make perceivable quality deterioration during the 10 days at $7^{\circ}C$. The hardness and color maintenance of the product vacuum packaged using PE film after washing with electrolyzed water, was better than that of other treatments.

  • PDF

Study on Reduction of Microbial Contamination on Daruma by Combination Treatment of Strong Acidic Hypochlorous Water and Ultrasonic Waves (강산성차아염소산수와 초음파를 병용처리한 조미오징어 반가공품의 미생물 오염도 저감화에 관한 연구)

  • Chung, Won-Hee;Ko, Jun-Soo;Shin, Il-Shik
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.166-172
    • /
    • 2015
  • This study was performed to develop treatment method for reducing microbial contamination on Daruma (a semi-processed product of seasoned and dried squid) by combination of strong acidic hypochlorous water (SAHW) and ultrasonic waves (UW). The available chlorine concentration, oxidation reduction potential (ORP) and pH of SAHW were $69.67{\pm}0.58ppm$, $1071.33{\pm}4.16mV$ and 2.79, respectively. The 1.49 log CFU/g of viable cell count and 1.32 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of sodium hypochlorite solution (SHS) for 120 min. The 3.62 log CFU/g of viable cell count and 3.22 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 120 min. The antibacterial effects of SAHW were stronger than those of SHS at same available chroline concentration. SAHW treatment after washing strongly alkalic electrolyzed water (SAEW) showed better bactericidal effects than SAHW treatment only. The 4.0 log CFU/g of viable cell count was reduced, S. aureus was reduced below regulation limit (Log 2.0 CFU/g), and E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 90 min after washing with 20 times (w/v) of SAEW for 60 min. The viable cell number was reduced below detection limit and S. aureus was reduced below regulation limit when the Daruma was treated with 20 times (w/v) of SAHW for 60 min in ultrasonic washer. E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 10 min in ultrasonic washer. These results suggest that combination of SAHW and UW may be a good technique to reduce the microbial contamination in daruma.

A Study on the Effectiveness of Remanufacturing Technology for the Catalyzed Diesel Particulate Filter-trap(DPF) Deactivated by Diesel Exhaust Gas (촉매가 담지된 사용후 경유차 매연저감장치 DPF의 재제조 효과에 관한연구)

  • Choi, Kang-Yong;Park, Hea-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.957-964
    • /
    • 2010
  • The deactivated catalyzed diesel particulate filter-trap (DPF) was remanufactured by ultrasonic wave treatment with various prepared solutions, followed by active component re-impregnation, and the emission control performance and surface properties of remanufactured DPF were studied at various remanufacturing conditions. The proper ultrasonic wave cleaning time at various prepared solutions and optimal re-impregnation amounts of active component for the best emission control performance of DPF were investigated and its performance tests were also carried out with various temperatures for the conversions of CO, THC (total hydrocarbon) and PM (particulate matter) by catalytic reaction test unit using bypass gas from the diesel engine dynamo system. It was found that the emission control performance of DPF remanufactured with the high-temperature air washing, ultrasonic wave cleaning at acid/base solutions and active component re-impregnation method was recovered to 95% level of its activity compared to that of the fresh DPF, which was caused by removing the deactivating materials from the surface of the DPF, through the analyses of performance test and their surface characterization by Optical microscope, EDX, ICP, TGA, and porosimeter.

Optimal Organic Solvent Extraction Method for Dewaxing of Beeswax-treated Hanji (밀랍도포한지의 탈랍을 위한 최적 유기용매 추출기법 탐색)

  • Choi, Do-Chim;Choi, Eun-Yeon;Jo, Byoung-Muk;Cho, Byoung-Uk
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.6
    • /
    • pp.50-57
    • /
    • 2012
  • In this study, the beeswax extraction methods using organic solvents were examined to develop a optimal dewaxing technology for beeswax-treated Hanji. Thermally-aged beeswax-treated Hanji was dewaxed using four types of extraction methods including dipping, Soxhlet extraction, ultrasonic washing and shaking methods. Then, the aging stability of the dewaxed Hanji was evaluated in terms of variations in paper strength and in the color of the printed area with muk. The experimental results suggested that the dewaxing methods allowing solvent to flow during extraction showed superior extraction efficiency. The dipping method in which the organic solvent does not flow showed the slowest extraction rate of beeswax compared to three other methods. In terms of variations in tensile strength and folding endurance, however, no obvious differences in the aging stability were observed amongst these four extraction methods. Regarding the aging stability in terms of the color of the printed area with muk, Soxhlet extraction method showed the best performance of dewaxing.

Development of Robot System for Colony Picking (II) - Performance test of the robot system - (콜로니 픽킹 로봇 시스템의 개발 (II) - 로봇 시스템의 성능실험 -)

  • 이현동;김기대;나건영;이영규
    • Journal of Biosystems Engineering
    • /
    • v.28 no.5
    • /
    • pp.449-456
    • /
    • 2003
  • A robot system was developed to pick desired colony. This robot system consisted of an image acquisition process which acquires the image information of colony, an illumination device which irradiates the object once when it gets the image of it, a picking head, a replicating head, a bed for fixing well-plates, and a sterilization device of sterilizing pin stained with colony. Picking pins were washed in an ultrasonic wave washing for takes ten seconds. Picking pins were dipped for sterilizing in alcohol for ten seconds. The time for resterilizing picking pins in a heater was five seconds. This performance test resulted 100% success rate for both the colony picking and the colony replication process. Considering the procedure in which 8 pins were smeared by colony, picked on a well plate, and sterilized as one cycle, the system could carry out one cycle in 110 seconds. It took about 138 minutes to pick around 600 colonies.