• Title/Summary/Keyword: ultrasonic surface waves

Search Result 105, Processing Time 0.03 seconds

Construction of the Intelligence Stress Predictor for Compression Strength Evaluation (압축강도 평가를 위한 지능형 응력예측기 구축)

  • 박원규;우영환;이종구;윤인식
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.95-101
    • /
    • 2001
  • This work is concerned with construction of the intelligence stress predictor far compression strength evaluation using neural network-ultrasonic waves. The contact pressure in jointed plates was measured by using ultrasonic technique. Neural network is used to evaluate and predict contact pressure from the results of the calibration curves. The organized neural system was leaned with the accuracy of 99%, as a result of learning the ultrasonic echo ratio to the contact pressure measurement between SM45C and STS410 materials. And it could be evaluated and predicted with the accuracy of 90% in the evaluation of ultrasonic echo ratio difference in the same surface roughness and contact pressure, and 85% in the prediction of virtual ultrasonic echo ratio. Thus the proposed stress predictor is very useful for the evaluation and prediction of the contact pressure between SM45C and STS410 materials.

  • PDF

A Study on the Enhancement of Phase Change Heat Transfer in Acoustic Fields (음향장 내의 상변화 열전달 촉진에 관한 연구)

  • 양호동;나기대;오율권
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2004
  • The present study investigates on the experimental and numerical results of heat transfer in the acoustic fields induced by ultrasonic waves. The strong upwards flow which moves from the bottom surface in a cavity to the free surface called as "acoustic streaming" was visualized by a particle image velocimetry (PIV). In addition, the augmentation ratio of heat transfer was experimentally investigated in the presence of acoustic streaming and was compared with the profiles of acoustic pressure calculated by the numerical analysis. A coupled finite element-boundary element method (FE-BEM) was applied for a numerical analysis. The results of experimental and numerical studies clearly show that acoustic pressure variations caused by ultrasonic waves in a medium are closely related to the augmentation of heat transfer.

A Study on the Absorption Phenomena of Ultrasonic Exergy in the Mortar with different Mixing Ratio of Sand to Cement (배합률의 변화에 의한 MORTAR의 초음파 흡수현상)

  • 전춘생;홍봉식
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.74-80
    • /
    • 1976
  • The temperature rise of the mortars while are being irradiated by ultrasonic waves and immersed in a liquid medium, are measured. The mixing ratios of sand to cement are varied for the different mortars. The results of the experiment are as follows, 1. The temperature rise of the mortar is decreased as themixing ration (S/C) is increased. 2. Thd temperature rise of the specimen is increased as its length is increased. 3. The surface conditions, either smooth or rough, may not have much influence on the temperature rise of the mortar. 4. The initial slope of temperature rise may not have much effect of the viscosity of liquid. The results, describes above, appear well coincide with the theory that the temperature rise is attributed mainly to the absorption heating. Since the absorption heating of the mortars varies with the mixing ratios of sand to cement, the strength of them would be estimated by means of irradiation of ultrasonic waves on the specimen.

  • PDF

A Study on a Quantitative Measurement of Contact Pressure Between two Rough Flat SurFaces by Means of Ultrasonic Waves. (초음파를 이용한 이체 평면접촉부의 정량적인 접촉압력 측정에 관한 연구)

  • 김경모;정인성
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.8-26
    • /
    • 1990
  • It is important to have exact information about the contact pressure distribution in the design of connected parts of machines and structures. In previous works, stress analyses on a two body contact problem have been carried out in large numbers. Besides, the measurement of contact stress is important to confirm the adequateness of the theoretical analysis, to verify appropriateness of Hertzian contact theory and to know the practical pressure distribution, but an excellent measuring method con't be found at present. Therefore, a quantitative measurement of contact pressure by means of ultrasonic waves using a normal probe and an angle has been proposed to measure the contact pressure distribution between two rough flat surfaces. At first, in a new proposed calibration method, the relation between mean contact pressure and sound pressure of reflected waves is obtained by using calibration blocks with various surface roughnesses made of the same material as the rectangular section beams And then, this experimental results are compared with the analytical ones, and the utility of this method is discussed.

  • PDF

A study on Contact Pressure Measurement of SM45C/STS410 Materials by Means of Ultrasonic Waves (초음파에 의한 SM45C/STS410재의 접촉압력측정에 관한 연구)

  • Yi, W.;Yun, I.S.;Jeong, E.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.11
    • /
    • pp.92-99
    • /
    • 1996
  • The contact pressure in jointed plates was measured by means of an improved ultrasonic technique. In order to get calibration curve, the relationship between contact pressure and ratio of boundary and bottom echo of normal beam probes were obtained for the calibration blocks with various surface roughness. The ratio of boundary and bottom echoes were measured for the upper/under plates locally compressed with uniform pressure, and the distribution of contact pressure was obtaines. The measured pressure has a good agreement with results of FEM analysis. Thus the proposed ultrasonic method in this work is very useful to measure the contact pressure.

  • PDF

A Technique for Measuring Ship's Draught by ultrasonic Pulse Signal

  • Lee, Eun-Bang;Lee, Sang-Jib
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1995.11a
    • /
    • pp.184-192
    • /
    • 1995
  • Although ship's draught information onboard is substantial for both the safety of navigation and the estimation of loaded cargoes its accuracy depends in traditional surveying method on the skillfulness of observers and the condition of the sea surface round the vessel. To obtain more accurate information accessibly measuring instruments with sophisticated sensors such as mechanical electronic and ultrasonic transducers have been developed. however they have still limitation in accuracy and in making up a system due to the complexity of processing signal. In this paper we propose a he technique for analyzing ultrasonic pulse signal in order to improve the measurement accuracy and simplify a remote sensing system of draught by ultrasonic waves. This technique is useful for measuring draught being considered the influence of sea surface fluctuation and for transferring its data briefly to required equipment in integrated bridge system.

  • PDF

Effect of the Amplitude in Ultrasonic Nano-crystalline Surface Modification on the Corrosion Properties of Alloy 600

  • Kim, Ki Tae;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.196-205
    • /
    • 2019
  • Surface modification techniques are known to improve SCC by adding large compressive residual stresses to metal surfaces. This surface modification technology is attracting attention because it is an economical and practical technology compared to the maintenance method of existing nuclear power plants. Surface modification techniques include laser, water jet and ultrasonic peening, pinning and ultrasonic Nano-crystal surface modification (UNSM). The focus of this study was on the effect of ultrasonic amplitude in UNSM treatment on the corrosion properties of Alloy 600. A microstructure analysis was conducted using an optical microscope (OM), scanning electron microscope (SEM) and electron backscattering diffraction (EBSD). A cyclic polarization test and AC-impedance measurement were both used to analyze the corrosion properties. UNSM treatment influences the corrosion resistance of Alloy 600 depending on its amplitude. Below the critical amplitude value, the pitting corrosion properties are improved by grain refinement and compressive residual stress, but above the critical amplitude value, crevices are formed by the formation of overlapped waves. These crevices act as corrosion initiators, reducing pitting corrosion resistance.

Visualization of Disruptive Bubble Behavior in Ultrasonic Fields (초음파장내 파괴적인 기포의 운동 가시화)

  • Kim, Tae-Hong;Park, Keun-Hwan;Kim, Ho-Young
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.1
    • /
    • pp.17-19
    • /
    • 2011
  • The bubble oscillations play an important role in ultrasonic cleaning processes. In the ultrasonic cleaning of semiconductor wafers, the cleaning process often damages micro/nano scale patterns while removing contaminant particles. However, the understanding of how patterns in semiconductor wafers are damaged during ultrasonic cleaning is far from complete yet. Here, we report the observations of the motion of bubbles that induce solid wall damage under 26 kHz continuous ultrasonic waves. We classified the motions into the four types, i.e. volume motion, shape motion, splitting or jetting motion and chaotic motion. Our experimental results show that bubble oscillations get unstable and nonlinear as the ultrasonic amplitude increases, which may exert a large stress on a solid surface raising the possibility of damaging microstructures.

Evaluation of the Surface Crack by a Large Aperture Ultrasonic Probe (대구경 초음파 탐촉자를 이용한 표면균열 평가)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.180-185
    • /
    • 2004
  • Conventional ultrasonic examination to detect micro and small surface cracks is based on the pulse-echo technique using a normal immersion focused transducer with high frequency, or an angle-beam transducer generating surface waves. It is difficult to make an automatic ultrasonic system that can detect micro and small surface cracks and position in a large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of the transducer. In this study, a high-precision scanning acoustic microscope with a 10MHz large-aperture transducer has been used to assess the existence, position and depth of a surface crack from the real-time A, B, C scans obtained by exploiting the ultrasonic diffraction. The ultrasonic method with large aperture transducer has improved the accuracy of the crack depth assessment and also the scanning speed by ten times, compared with the conventional ultrasonic methods.