• 제목/요약/키워드: ultrasonic flow meter

검색결과 30건 처리시간 0.045초

가중계수법을 이용한 5회선 초음파 유량계의 유속적분방법의 불확도 평가 (Uncertainty Evaluation of Velocity Integration Method for 5-Chord Ultrasonic Flow Meter Using Weighting Factor Method)

  • 이호준;이권희;노석홍;황상윤;노영아
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.287-294
    • /
    • 2005
  • Flow rate measurement uncertainties of the ultrasonic flow meter are generally influenced by many different factors, such as Reynolds number, flow distortion, turbulence intensity, wall surface roughness, velocity integration method along the acoustic paths, and transducer installation method, etc. Of these influencing factors, one of the most important uncertainties comes from the velocity integration method. In the present study, a optimization weighting factor method for 5-chord, which is given by a function of the chord locations of acoustic paths, is employed to obtain the mean velocity in the flow through a pipe. The power law profile is assumed to model the axi-symmetric pipe flow and its results are compared with the present weighting factor concept. For an asymmetric pipe flow, the Salami flow model is applied to obtain the velocity profiles. These theoretical methods are also compared with the previous Gaussian, Chebyshev, and Tailor methods. The results obtained show that for the fully developed turbulent pipe flows with surface roughness effects, the present weighting factor method is much less sensitive than Chebyshev and Tailor methods, leading to a better reliability in flow rate measurement using the ultrasonic flow meters.

  • PDF

가변 콘덴서를 이용한 디지털 수도미터의 설계 및 제작 (Design and Fabrication of Digital Water Meter Using a Variable Capacitor)

  • 박근형
    • 한국전기전자재료학회논문지
    • /
    • 제29권3호
    • /
    • pp.141-146
    • /
    • 2016
  • The AMR(automatic meter reading) system has been increasingly and widely used for its efficient and intelligent management, which is a technology that automatically collects consumption data from a water meter or energy metering device. The digital meter instead of the mechanical meter should be used in the system. Up to now, various types of sensor to measure the water flow rate have been used in the digital water meter, for example, reed switch, photo IR approximate sensor, ultrasonic sensor, electromagnetic sensor, etc. In this paper, a new sensing technology, where a variable capacitor and digital circuit were used for sensing the water flow rate, was proposed. The circuit was designed and verified by Pspice simulation. And a PCB board for the circuit was fabricated. After then, a prototype of digital water meter using a variable capacitor to measure the water flow rate was fabricated. The function tests of the fabricated digital water meter were performed, and it was found that the meter worked properly. Since the new technology has much better properties in terms of cost and power consumption compared to conventional technologies, it should be one of the major digital water meter technologies in the future.

유로망 해석에 의한 윤활유 공급펌프 성능 해석 (Performance Analysis of the Lubricating Oil Feed Pump by the Anslysis of the Flow Network)

  • 길두송;이영호
    • 동력기계공학회지
    • /
    • 제6권4호
    • /
    • pp.62-67
    • /
    • 2002
  • In this paper, the cause of the discrepancy of the inlet and outlet flow of the lubricating oil feed pump was analyzed by the flow measurement and the analysis of the flow network. At first, we thought that the flow difference was induced by a leak in the middle of the flow network. But, through the flow measurement using ultrasonic flow meter and the performance analysis of the pump, we knew that the cause of the flow difference was due to a drop in efficiency of the pump according to the pressure drop of the outlet. Also, we knew that the shape of the piping had no effect on the efficiency of the pump.

  • PDF

습식 다회선 초음파유량계의 특성평가 연구 (A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter)

  • 이동근;조용;고재명;박태진;박종호
    • 한국유체기계학회 논문집
    • /
    • 제16권4호
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

초음파 가스 유량계 개발 연구 (Study on the Development of Ultrasonic Gas Flowmeter)

  • 황원호;박상국;장경영
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.138-143
    • /
    • 2003
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG. COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has been proven by extensive field tests for several months in POSCO, iron & steel making company.

초음파 가스 유량계 개발 연구 (Study on the development of ultrasonic gas flowmeter)

  • 황원호;박상국;양규홍;장경영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.76-81
    • /
    • 2001
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has already well been proven by extensive field tests for several months in POSCO, iron & steel making company.

  • PDF

낙동강하굿둑 통합관리를 위한 3차원 고정식 유량 측정 자료를 이용한 하굿둑 개도 방류량 산정 기법 개발 (A Study on the Development of a method for estimating the amount of gate opening discharge in estuary using the three-dimensional fixed measurement of flow data for Integrated Nakdong-river estuary management)

  • 강두기;서용재;임경모;박병우
    • 한국습지학회지
    • /
    • 제24권1호
    • /
    • pp.52-58
    • /
    • 2022
  • 최근 낙동강 하구의 통합물관리를 위한 다양한 노력과 연구가 진행되고 있다. 그러한 연구 중 하나로 3차원 고정식 초음파 유속계를 이용한 수문별 개도 방류량의 측정이 수행되고 있으나, 개도별 방류량 산정식 도출을 위한 실측 성과를 활용한 수리학적 및 통계적 처리 절차와 기법에 대한 연구는 기초적인 수준에 머물고 있다. 이에 본 연구에서는 3차원 고정식 초음파 유속계 측정자료를 이용한 자료 처리 기법을 개발하여 측정 데이터 기반의 유량계수 산정하고 이를 이용하여 방류량 산정식 개발 적용성을 검토하였다.

펄스 초음파 도플러 속도계의 제작에 관한 연구 (Construction of Ultrasound Pulsed Doppler Velocimeter)

  • 현석봉;김수용;이재수
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.25-39
    • /
    • 1994
  • 심장 벽의 운동속도와 혈관내 혈구의 유속을 측정하기 위해, 단일 채널 3.1MHz 펄스 도플러 속도계를 제작하였다. 도플러 속도계에 사용된 초음파 펄스의 폭과 펄스 반복주파수(PRF)는 각각 1$\mu$s과 6kHz이고, 후방 산란된 반향신호의 도플러 편이는 완전간섭성(coherent) 복조방식을 이용하여 위상 측정기에 감지된다. 위상 측정기의 출력신호로부터 레인지 게이트와 샘플 홀더, 대역여파기를 이용하여 작은 영역내에 있는 초음파 산란체의 평균속도에 해당하는 도플러 신호가 얻어진다. 도플러 신호의 평균 주파수는 영점교차의 카운터에 의해 측정되며 시간의 함수로 산란체의 순간 속도를 디스플레이한다. 채널 수와 거리 분해능을 증가시키면 혈관내의 혈류속도 분포도와 총 유량 그리고 혈류가속도를 측정할 수 있다.

  • PDF