• Title/Summary/Keyword: ultra-high-performance concrete (UHPC)

Search Result 192, Processing Time 0.035 seconds

Estimation of Punching Shear Strength for Ultra High Performance Concrete Thin Slab (강섬유 보강 초고성능 콘크리트 슬래브의 뚫림 전단 성능 평가)

  • Park, Ji-Hyun;Hong, Sung-gul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.2
    • /
    • pp.95-103
    • /
    • 2015
  • UHPC(Ultra High Performance Concrete) is used widely with its remarkable performance, such as strength, ductility and durability. Since the fibers in the UHPC can control the tensile crack, the punching shear capacity of UHPC is higher than that of the conventional concrete. In this paper, seven slabs with different thickness and fiber volume ratio were tested. The ultimate punching shear strength was increased with the fiber volume ratio up to 1%. The shear capacity of specimens with the fiber content 1% and 1.5% do not have big differences. The thicker slab has higher punching shear strength and lower deformation capacity. The critical sections of punching shear failure were similar regardless of the fiber volume ratio, but it were larger in thicker slab.

Evaluation of Flexural Strength for UHPC Deck Joints with Lap-Spliced Reinforced Steel Bar (UHPC 바닥판 철근겹침이음 연결부의 휨강도 평가)

  • Hwang, Hoon Hee;Yeo, In Soo;Cho, Keun Hee;Park, Sung Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.92-99
    • /
    • 2011
  • Ultra High Performance Concrete(UHPC) is a superior structural material with high strength and durability. Construction of light and slim structures is realized to apply this expectable new materials in practice. This research is a part of the project to develop UHPC precast deck system for hybrid cable stayed bridge. The main object of this study is to investigate behavior of the lap-spliced reinforced connection in UHPC. The major parameter considered in experimental plan was lap-spliced length. The 4-points bending test for 12 specimens were conducted to verify the effect of considered parameters. Test results show that the minimum value of lap spliced length of 300mm which specified in current korea high bridge design code was very conservative for UHPC precast deck system.

An Experimental study on the bonding shear performance evaluation of UHPC accordance with adhesion surface treatment (콜드조인트 계면 처리방법에 따른 초고성능 콘크리트의 전단접착성능에 관한 실험적 연구)

  • Kim, Min-Seong;Lee, Seung-Yup;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.86-87
    • /
    • 2015
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on bonding shear strength of UHPC is required to be studied due to the lack of information. In this study, experimental research progress for bonding shear strength (shear strength of adhesive surface) evaluation of UHPC (Ultra High Performance Concrete) is proceeded. First, specimens that surface treatment methods of concrete bonded section and retardation time of placement are considered are produced. Second, Direct Shear test is applied on concrete bonded section of UHPC. As a result of this study, the highest bonding shear strength specimen in which compared to the non-retardation time specimen is compaction turbulence treatment. From later study, it is judged that strength of UHPC in accordance with direction of steel fiber when steel fiber of UHPC is mixed.

  • PDF

A Study on the Quality Control of 80MPa UHPC according to the Measurement Method of Compressive Strength (압축강도 측정방법에 따른 80MPa급 UHPC의 품질관리에 관한 연구)

  • Koo, Hyun-Chul;Moo, Ji-Hun;Lee, Hak-ju;Park, Min-Sang;Choi, Sung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.176-177
    • /
    • 2019
  • Recently, efforts are made to apply 200MPa levels of ultra-high strength concrete to structures exceeding 40MPa.. Ultra-high strength concrete has been steadily researched in Korea as well as abroad, and now it is equipped with 200MPa ultra-high strength concrete mixing technology. Because ultra-high strength concrete has a higher range of compressive strength than ordinary concrete, it is difficult to accurately measure the compressive strength of UHPC concrete with existing compressive strength measuring equipment and can be less reliable. In this study, the compressive strength of the SC80 was measured according to the test method to compare the compressive strength of the SC80 by applying various methods of measurement of compressive strength. The compressive strength test method measured the compressive strength according to the size of the specimen, the grinding method, and the capacity of the UTM equipment.

  • PDF

Mix design and early-age mechanical properties of ultra-high performance concrete

  • Tang, Chao-Wei
    • Advances in concrete construction
    • /
    • v.11 no.4
    • /
    • pp.335-345
    • /
    • 2021
  • It is known from the literature that there are relatively few studies on the engineering properties of ultra-high performance concrete (UHPC) in early age. In fact, in order to ensure the safety of UHPC during construction and sufficient durability and long-term performance, it is necessary to explore the early behavior of UHPC. The test parameters (test control factors) investigated included the percentage of cement replaced by silica fume (SF), the percentage of cement replaced by ultra-fine silica powder (SFP), the amount of steel fiber (volume percent), and the amount of polypropylene fiber (volume percentage). The engineering properties of UHPC in the fresh mixing stage and at the age of 7 days were investigated. These properties include freshly mixed properties (slump, slump flow, and unit weight) and hardened mechanical properties (compressive strength, elastic modulus, flexural strength, and splitting tensile strength). Moreover, the effects of the experimental factors on the performance of the tested UHPC were evaluated by range analysis and variance analysis. The experiment results showed that the compressive strength of the C8 mix at the age of 7 days was highest of 111.5 MPa, and the compressive strength of the C1 mix at the age of 28 days was the highest of 128.1 MPa. In addition, the 28-day compressive strength in each experimental group increased by 13%-34% compared to the 7-day compressive strength. In terms of hardened mechanical properties, the performance of each experimental group was superior to that of the control group (without fiber and without additional binder materials), with considerable improvement, and the experimental group did not produce explosive or brittle damage after the test. Further, the flexural test process found that all test specimens exhibited deflection-hardening behavior, resulting in continued to increase carrying capacity after the first crack.

Influence of Cover Size on Transfer Length of Prestressing Strand in Pretensioned Prestressed Ultra High Perfrmance Concrete Members (피복에 따른 초고성능 콘크리트 프리텐션부재의 응력전달길이 변화)

  • Park, Jong-Sup;Lee, Kyu-Wan;Kim, Byong-Suk;Joh, Chang-Bin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.95-96
    • /
    • 2009
  • In this paper, the transfer lengths in pretensioned prestressed Ultra High Performance Concrete members are verified to collect the basis data of UHPC increased in practical uses recently. The cover sizes and pretension forces were the main parameters of UHPC.

  • PDF

The Bond Characteristics of Strand in Ultra High Performance Concrete (강연선과 초고성능 콘크리트의 부착특성)

  • Park, Jong-Sup;Kim, Byong-Suk;Joh, Chang-Bin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.93-94
    • /
    • 2009
  • In this paper, the bond performance between prestressing strand and Ultra High Performance Concrete members are verified to collect the basis data of UHPC increased in practical uses recently. Concrete pouring direction, strand location and strand size were the main parameters of UHPC. As a result, the initial bond performances are influenced by all above parameters.

  • PDF

Experimental & numerical investigation of mechanical properties in steel fiber-reinforced UHPC

  • Dadmand, Behrooz;Pourbaba, Masoud;Sadaghian, Hamed;Mirmiran, Amir
    • Computers and Concrete
    • /
    • v.26 no.5
    • /
    • pp.451-465
    • /
    • 2020
  • This paper presents experimental and numerical investigations on mechanical properties of ultra-high-performance fiber-reinforced concrete (UHPFRC) with four types of steel fibers; micro steel (MS), crimped (C), round crimped (RC) and hooked-end (H), in two fiber contents of 1% and 2% (by volume) and two lengths of 13 and 30 mm. Compression, direct tension, and four-point bending tests were carried out on four types of specimens (prism, cube, dog-bone and cylinder), to study tensile and flexural strength, fracture energy and modulus of elasticity. Results were compared with UHPC specimens without fibers, as well as with available equations for the modulus of elasticity. Specimens with MS fibers had the best performance for all mechanical properties. Among macro fibers, RC had better overall performance than H and C fibers. Increased fibers improved all mechanical properties of UHPFRC, except for modulus of elasticity, which saw a negligible effect (mostly less than 10%). Moreover, nonlinear finite element simulations successfully captured flexural response of UHPFRC prisms. Finally, nonlinear regression models provided reasonably well predictions of flexural load-deflection behavior of tested specimens (coefficient of correlation, R2 over 0.90).

Seismic retrofitting of a tower with shear wall in UHPC based dune sand

  • Trabelsi, Abderraouf;Kammoun, Zied;Beddey, Aouicha
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.591-601
    • /
    • 2017
  • To prevent or limit the damage caused by earthquakes on existing buildings, several retrofitting techniques are possible. In this work, an ultra high performance concrete based on sand dune has been formulated for use in the reinforcement of a multifunctional tower in the city of Skikda in Algeria. Tests on the formulated ultra high performance concrete are performed to determine its characteristics. A nonlinear dynamic analysis, based on the "Pushover" method was conducted. The analysis allowed an optimization of the width of reinforced concrete walls used in seismic strengthening. Two types of concrete are studied, the ordinary concrete and the ultra high performance concrete. Both alternatives are compared with the reinforcement with carbon fibers and by base isolation retrofit design.

A study on the Evaluation of Surface Properties of UHPC Panels following long-term outdoor exposure (옥외 장기폭로에 따른 UHPC 패널의 표면 특성 평가 연구)

  • Kim, Tae-Ik;Choi, Byung-Keol;Park, Yong-Kyu;Choi, Sang-Hoon;Yoon, Gi-Won;Lee, Dae-Seek
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.176-177
    • /
    • 2022
  • In this study, surface performance evaluation was conducted according to the fiber and surface finishing technique of the exterior material using Ultra High Performance Concrete(UHPC), whitch is spotlighted as a highly durable exterior material. As a result of outdoor exposure, the initial performance of the UHPC Panel using organic fibers was maintained without being affected by the surface finishing technique. In the specimen using steel fiber, the surface performance was maintained when the water repellent treatment was performed in the plain specimen, but fiber corrosion occurred in the specimen to which the surface finishing technique was applied.

  • PDF