• Title/Summary/Keyword: ultra-high-molecular-weight polyethylene

Search Result 67, Processing Time 0.031 seconds

Ballistic Analysis and Stacking Sequence of Laminate Plate for Enhancing Bulletproof Performance (방탄 성능 향상을 위한 적층 평판의 피탄 해석 및 적층 배열 연구)

  • Ki Hyun Kim;Min Kyu Kim;Min Je Kim;Myung Shin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2023
  • Modern bulletproof armor must be light and have excellent penetration resistance to ensure the mobility and safety of soldiers and military vehicles. The ballistic performance of heterogeneous structures of laminated flat plates as bulletproof armor depends on the arrangement of constituent materials for the same weight. In this study, we analyze bulletproof performance according to the stacking sequence of laminated bulletproof armor composed of Kevlar, ultra-high molecular weight polyethylene, and ethylene-vinyl-acetate foam. A ballistic analysis was performed by colliding a 7.62 × 51 mm NATO cartridge's M80 bullet at a speed of 856 m/s with six lamination arrangements with constituent materials thicknesses of 5 mm and 6.5 mm. To evaluate the bulletproof performance, the residual speed and residual energy of the projectile that penetrated the heterogeneous laminated flat plates were measured. Simulation results confirmed that the laminated structure with a stacking sequence of Kevlar, ultra-high molecular weight polyethylene, and ethylene-vinyl-acetate foam had the best bulletproof performance for the same weight.

A Basic Study on Functional Friction Surface of Artificial Joints (내마모성이 향상된 기능성 표면구조를 갖는 인공관절에 관한 기초적인 연구)

  • ;T. Yuhta
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.519-526
    • /
    • 2001
  • At present. about 0.3 million and more THRs (Total Hip Replacement) in a rear are being done worldwide. The increase in mechanical failure with the increase in THR, required more revisions. Revisions compensate mainly the wear of the artificial joint frictional surface and the loosening of the cup and stem. According to recent researches, loosening is mainly due to wear debris UHMWPE (Ultra High Molecular Weight Polyethylene) from frictional surfaces . To overcome the wear problems associated with artificial joint materials , new surface structures with regular Patterns were designed and fabricated The lubrication Properties were examined to evaluate the wear of the frictional surfaces. The surface structure manifested a Pattern of "dents" with a 0.2-1.0 mm of diameter and 0.6-2.0 mm of Pitch. From the friction test of the SUS316L vs UHMWPE using the frictional tester, we found that the lubrication Performance was improved due to of drastically reduced amount of abrasion. There were optimum sizes for the diameter and the pitch of the Pattern. The results demonstrated that the lubrication properties could be improved by Patterning of the frictional surfaces. The surface Patterning was effective in preventing wear of the frictional surfaces, and the life of an artificial joint could be extended with such Patterning.

  • PDF

Friction and Wear Behaviour of CNT added UHMWPE (탄소나노튜브가 첨가된 UHMWPE의 마찰.마멸 거동)

  • 주영석;안정욱;임대순
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.354-359
    • /
    • 2001
  • CNTs were added to Ultra-high molecular weight polyethylene (UHMWPE) to improve the tribological properties of UHMWPE. CNTs which have a diameter of about 10-50nm, while their length is about 3-5nm were produced by the catalytic decomposition of tile C$_2$H$_2$ using a tube furnace. UHMWPE/CNTs composites were fabricated by hot pressing method. It is shown that friction coefficient was increased and wear resistance was improved as CNTs were added to UHMWPE because of excellent mechanical properties of CNTs located on UHMWPE surface.

  • PDF

인공관절의 수명 향상을 위해 Plasma Immersion Ion Implantation & Deposition 공정으로 증착된 NbN 박막에 대한 UHMWPE Liner 소재의 마모량 평가

  • Park, Won-Ung;Kim, Eun-Gyeom;Jeon, Jun-Hong;Choe, Jin-Yeong;Mun, Seon-U;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.137-137
    • /
    • 2012
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위하여 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 라이너(Liner)와 헤드(Head) 부분이 직접적인 마모 운동을 수행하게 되므로, 이 부분의 소재 특성에 따라 인공관절의 수명이 결정 되게 된다. 현재 헤드 소재로서는 Co-Cr-Mo 합금이, 라이너 소재로서는 고분자 소재인 UHMWPE (Ultra High Molecular Weight Polyethylene)가 주로 사용되고 있다. 이러한 MOP (Metal-On-Polymer) 구조의 인공관절의 경우, 충격흡수의 장점이 있는 반면, 관절 운동시 발생하는 UHMWPE 의wear debris에 의해 골용해가 발생하게 되어 인공관절의 수명이 저하되는 문제점이 있으며, 금속 헤드의 마모로 인한 금속이온의 용출은 세포 독성의 문제를 야기하여 인공관절의 수명을 저하시키는 또 다른 원인이 되고 있다. 따라서 본 연구에서는 PIII&D (Plasma Immersion Ion Implantation & Deposition) 공정을 이용하여 금속 (Co-Cr-Mo 합금)소재 위에 세라믹 (niobium nitride) 박막을 증착하여 상대재인 UHMWPE의 마모를 줄이고자 하는 연구를 진행하였다. 금속 소재 위에 증착된 세라믹 박막은 상대재인 UHMWPE의 마모량을 줄여줄 뿐만 아니라 금속이온의 용출을 막아준다는 장점이 있으나, 장시간의 마모 운동에 의하여 발생하는 박막의 박리 현상은 인공관절의 수명을 급격히 저하시키는 또 다른 원인이 된다. 이러한 단점을 해결하기 위하여, 박막의 증착 초기에 이온주입과 증착을 동시에 수행하는 dynamic ion mixing공정을 수행하였다. Dynamic ion mixing 공정을 수행함에 따라 박막과 금속 사이의 접착력이 증가하게 되어, UHMWPE의 마모량이 2배 가까이 감소하는 것을 확인할 수 있었으며, 장시간의 마모시험에서도 우수한 결과를 얻을 수 있었다. 또한 UHMWPE의 마모량을 감소시키기 위하여 박막을 증착하기 전에 금속 소재에 질소 이온주입을 수행하는 pre-ion implantation 공정을 도입하였다. 질소 이온주입 결과 Co-Cr-Mo 합금 표면에 부분적으로 CrN, Cr2N의 세라믹 상이 형성 되는 것을 확인할 수 있었으며, 그에 따라 UHMWPE의 마모량이 2배 이상 감소 되는 것을 확인 할 수 있었다.

  • PDF

Polyethylene-Based Dielectric Composites Containing Polyhedral Oligomeric SilSesquioxanes Obtained by Ball Milling

  • Guo, Meng;Frehchette, Michel;David, Eric;Demarquette, Nicole Raymonde
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.2
    • /
    • pp.53-61
    • /
    • 2015
  • High-energy ball milling was tested as a method for producing Ultra High Molecular Weight Polyethylene (UHMWPE)- based nanodielectrics containing 1 wt% and 5 wt% OctaIsoButylPOSS (OibPOSS). Qualitative and quantitative evaluations were used to explore the compatibility between OibPOSS and PE. Several ball milling variables were optimized in a bid to achieve UHMWPE/OibPOSS nanodielectrics. The morphology, as well as the thermal and the dielectric properties of the samples, were characterized by scanning electron microscopy, thermogravimetric analysis, broadband dielectric spectroscopy, and progressive-stress breakdown tests. The results showed that (i) ball milling was an effective method for producing UHMWPE/OibPOSS dielectric composites, but appeared ineffective in dispersing OibPOSS at the nanoscale, and (ii) the resulting UHMWPE/OibPOSS dielectric composites presented thermal and dielectric properties similar to those of neat UHMWPE.

Hemiarthroplasty for Osteosarcoma of Proximal Tibia (근위 경골의 골육종에 시행한 반관절성형술)

  • Jeon, Dae-Geun;Cho, Wan-Hyeong;Kim, Jin-Wook-;Koh, Han-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • Purpose: The proximal tibial sarcoma patients, especially in their growing ages have problems of reconstruction. This study is to devise a methodology which can circumvent this limitations. Materials and Methods: Four cases of proximal tibial osteosarcoma underwent hemiarthroplasty. The mean age was 13 years (11~15) with a mean follow-up of 64 months (47~89). The procedure consists of ultrahigh molecular weight polyethylene (UHMWPE) liner as an substitute for the joint surface and this piece was fixed to the remaining tibial bone stock with Ender nail and bone cement. Results: Final functional score was 23.5 (78.3% of control) by MSTS criteria. All the cases showed stable joint without pain. Hemiarthroplasty related complications were absent. By saving the femoral physis, expected leg length discrepancy could be minimized by this procedure. Conclusions: Hemiarthroplasty of proximal tibia can be an option in pediatric sarcoma patients.

  • PDF

A Study on the Impact Behavior of Bulletproof Materials According to the Combining Method

  • Jihyun Kwon;Euisang Yoo
    • Elastomers and Composites
    • /
    • v.57 no.4
    • /
    • pp.157-164
    • /
    • 2022
  • Representative bulletproof materials, such as aramid or ultra-high molecular weight polyethylene(UHMWPE), have excellent strength and modulus in the plane direction but are very vulnerable to forces applied in the thickness direction. This paper reports a study on the effects of reinforcement in the thickness direction when bulletproof composite fabrics are prepared to improve their performance. Aramid and UHMWPE fabrics were combined using the film-bonding, needle-punching, or stitching methods and then subjected to low-velocity projectile and ball-drop impact tests. The results of the low-velocity projectile test indicated that the backface signature(BFS) decreased by up to 29.2% in fabrics obtained via the film-bonding method. However, the weight of the film-bonded fabric increased by approximately 23% compared with that obtained by simple lamination, and the fabric stiffened on account of the binder. Flexibility, light weight for wearability, and excellent bulletproof performance are very important factors in the development of bulletproof materials. When the needle-punching method was used, the BFS increased as the fibers sustained damage by the needle. When the composite fabrics were combined by stitching, no significant difference in weight and thickness was observed, and the BFS showed similar results. When a diagonal stitching pattern was employed, the BFS decreased as the stitching density increased. By contrast, when a diamond stitching pattern was used, the fabric fibers were damaged and the BFS increased as the stitching density increased.

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

Biomechanical Fatigue Analysis of Cervical Plate Systems by using a Computer Simulation Based on Finite Element Method (유한요소법을 이용한 척추 삽입형 경추판 시스템에 대한 생체역학적 피로해석)

  • Kim, Sung-Min;Yang, In-Chul;Cho, Sung-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.96-103
    • /
    • 2008
  • In this study, we performed the biomechanical analysis of cervical plate systems by using a computer simulation based on finite element method to derive reliable model by analysis of design variables and fatigue behavior. To simulate the cervical spine movement in-vivo state by surgery, we modeled the cervical plate system which consisted of screws, rings, rivets, and plate and Ultra High Molecular Weight Polyethylene (UHMWPE) Block. The experiment of cervical plate system followed the ASTM F1717 standards that covered the materials and methods for the static and fatigue testing. The result of computer simulation is compared with experimented test. We expected this study is to derive reliable results by analysis of design variables and fatigue behavior for developing a new model.

Relationship between Crosslinking Processes and Mechanical Properties of UHMWPE for Artificial Joint (인공관절용 초고분자량폴리에틸렌의 가교결합 공정변수와 기계적 특성과의 상관관계)

  • Kim, H.M.;Kim, S.K.;Lee, J.D.;Yun, I.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1570-1574
    • /
    • 2008
  • Various mechanical test were conducted on conventional and crosslinked ultra-high molecular weight polyethylene(UHMWPE) all prepared from the same lot of medical grade GUR 1050 for artificial joint. The conventional materials were not irradiated and treated by heating. The cosslinked materials were irradiated with $25kGy{\sim}200kGy$ by gamma-ray andthen annealed or remelted. Gamma-ray irradiation and heat treatment process were found to significantly impact the crystallinity, and hence the mechanical behavior, of the highly crosslinked UHMWPE. The radiation dose and heating conditions were key predictors of the uniaxial yielding, plastic flow, and failure properties of conventional and highly crosslinked UHMWPE. The correlation model from experiments would be the basic information to enhance the were resistance of artificial joint liner.

  • PDF