• 제목/요약/키워드: ultimate shear strength

검색결과 494건 처리시간 0.025초

Ultimate strength behavior of steel plate-concrete composite slabs: An experimental and theoretical study

  • Wu, Lili;Wang, Hui;Lin, Zhibin
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.741-759
    • /
    • 2020
  • Steel plate-concrete composite slabs provide attractive features, such as more effective loading transfer, and more cost-effective stay-in-place forms, thereby enabling engineers to design more high-performance light structures. Although significant studies in the literatures have been directed toward designing and implementing the steel plate-concrete composite beams, there are limited data available for understanding of the composite slabs. To fill this gap, nine the composite slabs with different variables in this study were tested to unveil the impacts of the critical factors on the ultimate strength behavior. The key information of the findings included sample failure modes, crack pattern, and ultimate strength behavior of the composite slabs under either four-point or three-point loading. Test results showed that the failure modes varied from delamination to shear failures under different design factors. Particularly, the shear stud spacing and thicknesses of the concrete slabs significantly affected their ultimate load-carrying capacities. Moreover, an analytical model of the composite slabs was derived for determining their ultimate load-carrying capacity and was well verified by the experimental data. Further extensive parametric study using the proposed analytical methods was conducted for a more comprehensive investigation of those critical factors in their performance. These findings are expected to help engineers to better understand the structural behavior of the steel plate-concrete composite slabs and to ensure reliability of design and performance throughout their service life.

Static behaviour of multi-row stud shear connectors in high- strength concrete

  • Su, Qingtian;Yang, Guotao;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.967-980
    • /
    • 2014
  • In regions of high shear forces in composite bridges, headed stud shear connectors need to be arranged with a small spacing in order to satisfy the design requirement of resisting the high interface shear force present at this location. Despite this, studies related to groups of headed studs are somewhat rare. This paper presents an investigation of the static behaviour of grouped stud shear connectors in high-strength concrete. Descriptions are given of five push-out test specimens with different arrangements of the studs that were fabricated and tested, and the failure modes, load-slip response, ultimate load capacities and related slip values that were obtained are reported. It is found that the load-slip equation given by some researchers based on a single stud shear connector in normal strength concrete do not apply to grouped stud shear connectors in high-strength concrete, and an algebraic load-slip expression is proposed based on the test results. Comparisons between the test results and the formulae provided by some national codes show that the equations for the ultimate capacity provided in these codes are conservative when used for connectors in high-strength concrete. A reduction coefficient is proposed to take into account the effect of the studs being in a group.

보수$\cdot$보강된 철근콘크리트 보의 휨 및 전단 거동에 관한 연구 (A Study on the Flexural and Shear Behavior of Repaired and Rehabilitated RC Beams)

  • 김태봉;이재범;류택은
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.129-140
    • /
    • 1999
  • This study presents test results of RC beams strengthened by steel plates, carbon fiber sheets(CFS) and aramid fiber sheets(AFS) for increasing flexural and shear resistance. The test was performed with different parameters including the type of strengthening materials, flexural-strengthening methods and shear-strengthening methods. In case of flexural test, RC beams are initially loaded to 70% of the ultimate flexural capacity and in case of shear test loaded to 60 or 80 percent of the ultimate shear capacity and subsequently reinforced with steel plates, CFS and AFS. Experimental data on strength, steel strain, deflection, and mode of failure of the reinforced beams were obtained, and comparisons between the different shear reinforced schemes and the non-strengthened control beams were made. The test results showed that damaged RC beams strengthened by steel plates, CFS and AFS have more improved the flexural and shear capacity. For the beams with external reinforcement by steel plates, aramid fiber sheets and carbon fiber sheets increases in ultimate strength of 4 to 21, 17 to 43 and 26 to 36 percent were respectively achieved. Initial load had small effect on strength after reinforcement, but an important influence on deflection. One sheet reinforced was stronger than two sheets reinforced but less deflected than two sheets reinforced.

  • PDF

Behaviors of novel sandwich composite beams with normal weight concrete

  • Yan, Jia-Bao;Dong, Xin;Wang, Tao
    • Steel and Composite Structures
    • /
    • 제38권5호
    • /
    • pp.599-615
    • /
    • 2021
  • The ultimate strength behaviour of sandwich composite beams with J-hooks and normal weight concrete (SCSSBJNs) are studied through two-point loading tests on ten full-scale SCSSBJNs. The test results show that the SCSSBJN with different parameters under two-point loads exhibits three types of failure modes, i.e., flexure, shear, and combined shear and flexure mode. SCSSBJN failed in different failure modes exhibits different load-deflection behaviours, and the main difference of these three types of behaviours exist in their last working stages. The influences of thickness of steel faceplate, shear span ratio, concrete core strength, and spacing of J-hooks on structural behaviours of SCSSBJN are discussed and analysed. These test results show that the failure mode of SCSSBJN was sensitive to the thickness of steel faceplate, shear span ratio, and concrete core strength. Theoretical models are developed to estimate the cracking, yielding, and ultimate bending resistance of SCSSBJN as well as its transverse cross-sectional shear resistance. The validations of predictions by these theoretical models proved that they are capable of estimating strengths of novel SCSSBJNs.

전단보강이 없는 강섬유보강 콘크리트보의 전단강도 (Shear Strength of Steel Fiber Reinforced Concrete Beams without Stirrups)

  • 구성모;이정석;김우석;백승민;곽윤근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.591-596
    • /
    • 2001
  • Nine steel fiber reinforced high strength concrete beams and three steel fiber reinforced normal strength concrete beams without stirrups were tested by two point load. The variables studied in this investigation are the shear span/depth ratios of a/d = 2, 3 and 4, steel fiber volume fractions of V$_{f}$ : 0, 0.5% and 0.75% and concrete compressive strengths of f$_{ck}$: 630kgf/$cm^{2}$, and 310kgf/$cm^{2}$. Based on these tests and on tests by previous investigators, predictive equation is proposed for evaluating the ultimate shear strength of steel fiber reinforced concrete beams without stirrups. The proposed equation gave good prediction for the ultimate shear strength of the tested beams.

  • PDF

열수노화 조건에서 레저선박용 탄소섬유강화플라스틱의 강도변화에 관한 실험적 연구 (Experimental Study on the Hygrothermal Ageing Effect to the Strength of CFRP Materials for Marine Leisure Boat)

  • 정한구;노재규
    • 대한조선학회논문집
    • /
    • 제55권3호
    • /
    • pp.205-214
    • /
    • 2018
  • This paper deals with the experimental study on the hygrothermal ageing effect to the strength of Carbon Fiber Reinforced Plastics (CFRP) materials for marine leisure boat manufactured by vacuum assisted resin infusion method. The experiments performed consist of tensile, flexural and shear tests according to American Society for Testing and Materials (ASTM) and Korean Industrial Standards (KS) test methods. Test coupons are varied from uni-directional(UD, $0^{\circ}$, $90^{\circ}$), Bi-Directional (BD), and Double-Bias (DB) carbon fiber fabrics in conjunction with epoxy resin. The results of tensile test show that tensile strength reduces significantly while not the same degree of reduction is observed for elasticity modulus with respect to the existence of hygrothermal ageing effect. This implies that the tensile strain induced from external load holds steady values but ultimate strength values change widely under hygrothermal ageing effect. In case of the flexural test, $0^{\circ}$ UD shows more strength reduction than $90^{\circ}$ UD while BD has reduced values in both flexural strength and elasticity modulus under hygrothermal ageing effect. It is learned that the bending strain induced from external load and ultimate strength values are reduced with respect to hygrothermal ageing effect. Shear test performed only on DB materials, and the results show marginal reduction in ultimate strength and moderate reduction in elasticity modulus. This means that the shear strain varies more than ultimate shear strength with respect to hygrothermal ageing effect. The experiment conducted in this paper clearly demonstrates the differences in material properties of the CFRP for the consideration of hygrothermal ageing effect. Findings obtained from this experimental study can serve as a fundamental input data for the realistic structural responses of marine leisure boat built in CFRP materials.

강섬유 보강 초고성능 콘크리트 보의 전단 거동에 관한 실험 연구 (An Experimental Study on Shear Behavior of Steel Fiber-Reinforced Ultra High Performance Concrete Beams)

  • 양인환;조창빈;이정우;김병석
    • 대한토목학회논문집
    • /
    • 제32권1A호
    • /
    • pp.55-64
    • /
    • 2012
  • 이 연구에서는 강섬유 보강 초고성능 콘크리트 보의 전단거동를 파악하기 위한 실험연구를 수행하였다. I-형 단면을 갖는 단순지지 6개의 보 부재에 대해 3점하중 정적재하실험을 수행하여 전단 거동 특성을 분석하였다. 부재의 실험변수는 강섬유 혼입량과 전단지간-유효깊이 비이다. 강섬유 혼입량은 1.0, 1.5 및 2.0%로 변화하였고, 전단지간-유효깊이 비는 2.5 및 3.4로 변화하였다. 실험결과는 강섬유량이 증가할수록 극한전단강도가 증가하고, 전단지간-유효깊이 비가 증가할수록 극한전단강도가 감소하는 것을 나타낸다. 실험결과를 이용하여 기존 강섬유 보강 콘크리트 보의 전단강도 예측식의 적합성을 평가하고자 하였다. 전단강도 실험값을 기존의 제안식에 의한 전단강도 예측값과 비교하였으며, 비교결과는 예측식의 유효성을 나타내고 있다. AFGC와 JSCE의 제안식에 의한 전단강도 예측 평균값이 실험값에 거의 근접하고 있으며, 예측식 중에서 이들 제안식의 정확도가 가장 높은 것으로 나타난다.

고강도 철근콘크리트 보의 전단종국강도 산정식의 제안 (The Study on the Formula of Ultimate Shear Strength of Reinforced High-Strength Concrete Beams.)

  • 박기철;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.59-64
    • /
    • 1991
  • The purpose of this paper is to suggest the equations that are able to predict the ultimate shear strength of the reinforced high-strength concrete beams. For this analysis, total of 83 rectangular beams were tested, and existing data of 400 was adopted. Through this analysis, the following equations are obtained. a) Shear Tensile Failure Equation : TVu={K1.K2(3.02 $\sqrt[3]{\Fc}$/$sqrt{\a/d\}$+1.74Pt)+(0.18a/d+0.567)Pww$\sigma$y]bd b) Shear Compressive Failure Equation : cVu={(29.85 $\sqrt[3]{\Fc}$-130)$\sqrt{d/a}$+(0.089$\sqrt{a/d}$=0.04)Pww$\sigma$y}bd

  • PDF

강섬유(鋼纖維) 보강(補强)콘크리트보의 전단특성(剪斷特性)에 관한 연구(研究) (A Study on the Shear Properties of Steel Fiber Reinforced Concrete Beams)

  • 문제길;홍익표
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.1-12
    • /
    • 1993
  • 본 논문은 전단철근을 갖지 않는 강섬유보강콘크리트 보의 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 섬유로 보강된 21개의 보를 포함한 총 36개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 섬유혼입율, 전단지간, 인장철근량 등이며, 실험과정을 통해 파괴형상, 처짐, 전단강도 등을 측정하였다. 실험결과로부터 섬유의 혼입량이 많아지고, 콘크리트의 강도가 커질수록, 그리고 전단지간이 짧아질수록 섬유보강콘크리트 보의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험결과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안하였다. 제안된 추정식에 의한 계산값과 실험결과를 비교 검토하여 그 상관성을 확인하였다.

  • PDF

정착파괴가 관련된 깊은 보의 휨-전단 강도에 관한 연구 (Flexural and Shear Strength of RC Deep Beams related to Anchorage Failure)

  • 김대진;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.609-612
    • /
    • 1999
  • This study presents the plastic analysis for the flexural and shear strength of RC beams related to anchorage failure. Five failure mechanisms based on the upper bound solution were constructed and the ultimate strength equations were formulated from them. The parametric study herein was carried out to observe the variation of the controlling failure mechanism depending on the parameters in the ultimate strength equations. The results of the parametric study show that controlling failure mechanism and ultimate strength are determined through the interaction of each parameter. This indicated that respective structural configuratins must be treated in a unified manner. Additionally this study proposes the scope of the parameter to induce the flexural of RC deep beams.

  • PDF