• Title/Summary/Keyword: u-IT전력기기

Search Result 15, Processing Time 0.02 seconds

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

A Study on Performance Evaluation and Security Measures of U-IT Electrical Safety Integrated Management System's Module (U-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.307-310
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. U-City in order to prevent the disaster of U-IT Power Equipment Performance Module and the security for the safety of the U-City is necessary. In this paper, the power unit of U-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation and security measures will be studied. U-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as U-IT integrated management system for electrical safety and strengthen the security, safety and security with a U-City will contribute to the construction and operation.

  • PDF

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Bae, Suk-Myong;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.499-502
    • /
    • 2009
  • Supply of electric power and electricity safety for whole system and network are essential element. Electricity safety technology need rating for product and research about certification as product development that is done cotton flannel mixed with development of u-IT technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication and module for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in PD, Arc detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

  • PDF

A Study on the Domestic Technical Regulation of Low Power u-IT Equipments (저전력 u-IT 기기의 국내 기술 기준에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2249-2253
    • /
    • 2011
  • This paper analyzed the problems of the Korean output regulation in the relevant band through an analytic comparison of the current trend of each country and their standard values concerning the technical standard of low power u-IT equipments. In connection with the standard value of technical values of each country, which has been proposed in the registration of the appropriate electric wave, the paper aims to propose the standard value that could actually be introduced for suitable low power u-IT installations in Korea. Provided that the Korean standard may be upgraded based on the tolerances of technical standards proposed in this paper, this is expected to be committed to the distribution and advancement of low power u-IT equipments; and further, it is anticipated to be prepared with competitiveness not only in the Korean communications market, but also in the international communications market.

Performance Evaluation Simulation of Electrical IT Equipment for U-city Safety (U-city 안전을 위한 전기IT기기의 성능평가 시뮬레이션)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.159-163
    • /
    • 2011
  • U-City의 안전을 위하여 안전한 전기공급과 전기안전 점검과 전송에 필요한 전기IT 인프라는 중대한 요소이다. U-City의 건설에 필요한 전기IT기기의 설계와 개발 및 제조를 하고 Test-bed에 설치하여 성능 평가를 한 후에 검증을 맡은 전기IT기기를 U-City 설치하여야 한다. 본 논문에서는 U-City 안전을 위한 전기IT기기에 대한 절연저항, 누설전류에 따르는 고온, 연기, Co2, 불꽃, 화재 등을 감지하는 센서를 부착하고, 발생할 수 있는 재난을 사전에 예방하기 위해 전기안전보호기술, 전기설비를 상시 감시할 수 있는 기반기술, 설비를 원격으로 관리할 수 있는 제품에 대한 성능평가와 시뮬레이션을 통해 U-City에 구축되려는 종합적인 전력통합감시시스템을 연구한다.

  • PDF

Attack Analysis of Bluetooth Electrical IT equipment in Smart Grid (Smart Grid에 사용된 Bluetooth 전기IT기기에 대한 공격 분석)

  • Song, Jin-Young;Park, Dea-Woo;Kim, Eung-Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.91-94
    • /
    • 2011
  • Smart Grid에 사용되는 전기IT기기에서 Bluetooth의 보안 취약점이 발견되고 있다. 특히 전기안전을 위한 감시센서 정보전달을 맡고 있어서 위험성은 더욱 커진다. 본 논문은 Bluetooth가 탑재된 전기IT기기에 대한 Hacking Tool 분석을 실시하고, Bluetooth 취약점을 이용한 DoS, Sniffing공격 등 Tool 공격을 실행하고, Smart Grid와 U-IT 전기기기와 전력망에 대한 보안 방안 제시를 한다.

  • PDF

A Three-Phase Parallel Active Power Filter Operating with PCC Voltage Compensation by Controlling Reactive Power (무효전력 제어에 의한 PCC전압 보상을 갖는 삼상 병렬형 능동전력필터)

  • Lee, U-Cheol;Hyeon, Dong-Seok;Lee, Taek-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.211-218
    • /
    • 2000
  • The performance and dynamic characteristics of three-phase active power filter with PCC voltage compensation is presented and analyzed in this paper. The characteristics of parallel active filter are discussed when they are applied to nonlinear loads with current source and voltage source type, the characteristics of voltage compensator and comparison of two functions are discussed. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. First, it operates as a conventional active filter with reactive power compensation while PCC voltage is in a certain range. Second, is operates as a voltage compensator while PCC voltage is out of range. Finally, the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rated at 10KVA.

  • PDF

Information System of Smart u-LED Lighting Energy based on Zigbee Mesh Network (지그비 메쉬 망 기반 스마트 u-LED 전력제어 시스템)

  • Kim, Sam-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.77-83
    • /
    • 2013
  • Nowadays, the limitation of Lighting control and management skills is the excessive cost of equipments, the operational difficulties and wasting energy. To solve this problem is in need of communication and management S/W that is worked out complexly well as a information system of smart lighting energy, which is loaded wireless network facility. This paper made a study od the energy saving technology through energy monitoring and we developed LEIS(Lighting Energy Information Sysem) to converge this one. LEIS is monitoring and control lighting energy data that is collelcted from sensors by Zigbee mesh network and shows lighting use information by visualization to users. It is consists of lighting energy information data base based on LEM(Lighting Energy Metering) information and LEIS Web application, provide function scenario to manage energy optimization through LEIS.

Trend Analysis for Basic Design of a Plate and Shell Heat Exchanger (판형쉘열교환기 기본설계를 위한 경향성 분석)

  • Dong-Hyeon Choi;Yoon-Suk Chang;Sun-Yeh Kang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.69-76
    • /
    • 2022
  • In order to prepare for a future nuclear market, research for developing floating small modular reactor has been initiated with the aim of differentiating it from large nuclear power plants such as distributed power, heat supply to remote communities and sea water desalination. Depending on the characteristics of the small modular reactor, it is necessary to design a plate and shell heat exchanger that can be manufactured smaller than the U-tube recirculation method. In this study, 12 cases are selected by changing the diameter of the heat plate, the thickness of the device body and the size of the stiffener. Finite element analysis is performed by setting the stress classification lines for the point at which deformation is expected under external pressure conditions for these analysis cases. For the basic design of the plate and shell heat exchanger, the optimal conditions are derived by analyzing the tendency of stress change in the device body and stiffener.