• 제목/요약/키워드: type specimens

검색결과 2,196건 처리시간 0.03초

PC 전단벽 건식접합부에 관한 실험연구 (An Experimental Study on Dry-Connection for Precast Concrete Shear Walls)

  • 홍성걸;임우영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.21-24
    • /
    • 2005
  • In this study, new methods of PC panel connection using 'ㄷ'type steel connection is proposed for highly seismic zone. A study was carry out to investigate the connection behavior subjected to cyclic inelastic loading. Three planar type and two T type PC wall will be tested. The variables will be examined were the shear reinforcement existence of top and bottom walls. The specimens will be tested only reverse cyclic loading in accordance with a prescribed displacement history. To transfer the shear strength shear key set up between top and bottom wall. Failure mode, behavior, ductility and energy dissipation capacity of the specimens constructed by new connections wll be compared with those of monolithic walls and Han's(Han, Jun Hee, Seoul National University) model.

  • PDF

강상판(鋼床版) U형(形) 트라프리브 단차용접(段差熔接)이음부(部)의 피로강도(疲勞强度)에 관(關)한 연구(硏究) (A Study on the Fatigue Strength of a Welded Joint with Misalignment of a U-type Trough Rib in a Steel Deck Plate)

  • 이동욱;서원찬
    • 한국강구조학회 논문집
    • /
    • 제8권3호통권28호
    • /
    • pp.13-20
    • /
    • 1996
  • With the adoption of welded joints rather than bolted joints, we investigate the fatigue strength and the fatigue crack initiation of U-type trough rib and welded specimen with misalignment in a steel deck plate. The stress concentration factor of welded specimens with a misalignment is also verified by a finite element method. The main conclusions obtained from this study are as follows Experimental results of full-scaled U-type trough rib models have indicated that fatigue life depends on misalignments of welded joints in steel deck plate ; The more misalignments are, the less the fatigue life is. It has also shown that fatigue crack propagates from the welded root to the bead surface. We have also obtained the same results from both the fatigue test of welded specimens with a misalignment and the stress analysis of a finite element method.

  • PDF

환경조건에 따른 팽창성 혼화재 및 비스페놀 F형 에폭시수지 병용 모르타르의 자기치유 검토 (Self-Healing Investigation of Bisphenol F-Type Epoxy-Modified Mortars with Expansive Admixtures Under Outdoor Exposure Conditions)

  • 박승민;김완기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.22-23
    • /
    • 2017
  • The purpose of this study is to ascertain self-healing function on microcracks in bisphenol F-type epoxy-modified mortars using expansive admixtures. The specimens are prepared with various polymer-binder ratios of 0, 5, 10, 20%, expansive admixture contents of 0% and 10%, a sodium carbonate content of 0.25%, and subjected to exposure conditions of CR1, CR2, CR3 and CR4. The specimens are tested for self-healing effect, porosity and FE-SEM analysis. As a result, self-healing effects of bisphenol F-type EPMMs with expansive admixtures are visible in all of the outdoor exposure conditions. In particular, exposure conditions of CR3 and CR4 are most noticeable. And the porosity of EPMMs is reduced with an increase in the polymer-binder ratio, and is considerably smaller than that of unmodified mortar.

  • PDF

탄소섬유시트로 보강된 춤이 큰 철근콘크리트 보의 전단파괴거동(剪斷破壞擧動) (Shear Failure Behaviour of Reinforced Concrete Deep Beam Strengthened by Carbon Fiber Sheets)

  • 조수제;손성현;박성수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권4호
    • /
    • pp.145-153
    • /
    • 1999
  • The major objective of this study is to investigate experimentally the shear strengthening effect of carbon fiber sheets upon reinforced concrete deep beam and shear failure behavior variation of reinforced concrete deep beam strengthened by carbon fiber sheets. Tests are carried out with 6 specimens were shear failure at first loading tests, and with parameters including the types of shear strengthening of carbon fiber sheets (I type, S type, U type), and plies of sheets (2 ply and 1 ply). From the results of test, analyzed load-deflection of midspan, strain variation of main bars and transverse reinforcement, maximum load capacity of strengthened specimens, and compared with the previous test results.

  • PDF

Neotypification of Veronica pusanensis (Scrophulariaceae)

  • Jang, Hyun-Do;Noh, Tae-Kwon
    • Journal of Species Research
    • /
    • 제9권4호
    • /
    • pp.375-376
    • /
    • 2020
  • A type specimen is the specimen originally used to name a new species; thus, it is one of the most significant materials for taxonomic study. In our study on the inventory and management of endemic species in Korea, we checked the type materials for Pseudolysimachion pusanensis (Y. Lee) Y. Lee, combination name Veronica pusanensis Y. Lee, recorded as deposited at the herbaria of the Ewha Womans University and the National Institute of Biological Resources, and failed to find any specimens. Thus, we concluded that all type specimens of V. pusanensis have since been misplaced. According to articles 9.11 and 9.13 of the International Code of Nomenclature for algae, fungi, and plants, it is necessary to select a neotype if the holotype is missing and no other original material exists. Therefore, we designate the neotype maintained in the herbarium of the National Institute of Biological Resources of the Republic of Korea.

A Study on the Dielctric Properties of the PTC $BaTiO_3$ Ceramic Thin Films

  • Im, Ik-Tae;So, Byung Moon
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.63-67
    • /
    • 2012
  • The films were deposited at evaporator system and were annealed at heat treatment. The films had a dense microstructure with fine grains. The electrical properties of the films were dramatically controlled with annealing. Samples Preparation were analyzed in term of positive temperature coefficient of Resistivity Samples were made in the substrate tempera-true of $400^{\circ}C$ deposition time of 10 hours, and forward power of 210watt. R-T(resistivity-temperature) Characteristics of the samples were investigated as a function of the substrate type and the ambient temperature. The resistivity of the thin film specimens was compared with that of the bulk type specimens. By using RF/DC magnetron sputtering system, we obtained lower resistivity in the thermistor with thin $BaTiO_3$ film than that in the bulk type thermistor.

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • 제3권2호
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

Detection of Adenovirus from Respiratory and Alimentary Tract in Pusan, 1999

  • Cho, Kyung-Soon;Kim, Young-Hee
    • Journal of Life Science
    • /
    • 제10권2호
    • /
    • pp.17-20
    • /
    • 2000
  • Adenovirus which is an important infectious viral agent in respiratory and alimentary tract was investigated in Pusan, 1999. Fifteen cases of adenovirus were detected from stools and throat swabs of suspected patients. Two cases of enteric adenovirus were detected from a 5 years old boy and a 6-month-old boy. Thirteen cases of respiratory adenoviruses were detected from children aged under 10 years old and one adult. From respiratory specimens, 1 case of adenovirus type 2, 1 case of type 5, and 11 cases of type 3 were found. Enterotype 41 was detected from fecal preparations. Adenoviruses appeared mostly during winter months, January, February and December. Adenovirus showed a slowly progressive cytopathic effect on HEp-2 cells, Vero cells and BGM cells at 37$^{\circ}C$, in a 5-7% $CO_{2}$ incubation. An electron microscopic observation exhibited non-enveloped icosahedron with a diameter of 70nm. No significant differences on cytopathic effect and morphological features have been found from specimens of either alimentary tract or respiratory secretions.

  • PDF

치관 내 캔틸레버 양에 따른 내측 연결 형태 임플란트의 기계적 강도에 대한 연구 (Effect of intra-crown cantilever on mechanical strength of internal conical joint type implant)

  • 윤미정;허중보;정창모;전영찬;강은숙
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.360-367
    • /
    • 2015
  • Purpose : The purpose of this study was to evaluate the effect of amount of cantilever in intra-crown according to implant fixture position on mechanical strength of internal conical joint type implant. Materials and Methods : Internal conical joint type implant fixture, abutment screw, abutment was connected and gold alloy prostheses were fabricated and cemented on abutment. For fatigue fracture test, the specimens were loaded to the 350 N, 2,000,000 cycle on 3, 4, 5, and 6 mm off-center of gold alloy prostheses. The fracture pattern of implant component was observed. Results : No fatigue fracture found on 3 and 4 mm group. But initial crack pattern found on 3 specimens of 4 mm group. Fatigue fracture found on all specimens of 5 mm group. But complete fracture was not observed. One specimen of 6 mm group fracture completely. Implant fixture fracture wax not observed. Conclusion : The mechanical failure of implant prostheses increased with the loading area farther from center of implant fixture. To reduce mechanical problem of internal joint type implant, surgical and prosthetic consideration is needed.

네오니코치드계 목재보존제가 집성재 제조용 레조르시놀 수지의 접착력에 미치는 영향 (Effect of Neonicochid Type Wood Preservative on Adhesive Properties of Resorcinol Resin for Lminated Wood)

  • 이동흡;이종신
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권1호
    • /
    • pp.34-40
    • /
    • 2014
  • 흰개미 방제 및 방곰팡이 효력이 입증된 저독성 네오티코치드계 목재보존제가 집성재 제조용 레조르시놀계 접착제의 접착력에 미치는 영향을 조사하였다. ACQ, CUAZ, 네오니코치드계 약제를 도포 처리한 다음 건조시킨 소나무 판재를 사용하였으며, 집성 접착 후에 블록 전단시험편을 채취하여 상태 및 촉진 열화 시험 후의 전단접착력과 목파율을 측정하여 비교하였다. ACQ 및 CUAZ 처리 집성재는 무처리 및 네오니코치드계 목재보존제 처리 집성재에 비하여 낮은 전단접착력을 보여 접착력 저하가 인정되었다. 이것은 이들 방부제 중에 함유되어 있는 구리화합물에 기인하는 것으로 판단되었다. 네오니코치드계 목재보존제 처리 집성재는 상태 및 촉진열화 시험 후에도 가장 우수한 전단접착력을 나타내 레조르시놀계 접착제의 접착성능에는 영향을 미치지 않는 것으로 판단하였다.