• Title/Summary/Keyword: two-stage continuous process

Search Result 62, Processing Time 0.029 seconds

Implementation of a High Speed Comparator for High Speed Automatic Test Equipment (고속 자동 테스트 장비용 비교기 구현)

  • Cho, In-Su;Lim, Shin-Il
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.3
    • /
    • pp.1-7
    • /
    • 2014
  • This paper describes the implementation of high speed comparator for the ATE (automatic test equipment) system. The comparator block is composed of continuous comparator, differential difference amplifier(DDA) and output stage. For the wide input dynamic range of 0V to 5V, and for the high speed operation (1~800MHz), high speed rail-to-rail amplifier is used in the first stage. And hysteresis circuits, pre-amp and latch are followed for high speed operation. To measure the difference of output signals between the two devices under test (DUTs), a DDA is applied because it can detect the differences of both common signals and differential signals. This comparator chip was implemented with $0.18{\mu}m$ BCDMOS process and can compare the signal difference of 5mV up to the frequency range of 800 MHz. The chip area of the comparator is $620{\mu}m{\times}830{\mu}m$.

Operating Characteristics of a Continuous Two-Stage Bubbling Fluidized-Bed Process (연속식 2단 기포 유동층 공정의 운전특성)

  • Youn, Pil-Sang;Choi, Jeong-Hoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.81-87
    • /
    • 2014
  • Flow characteristics and the operating range of gas velocity was investigated for a two-stage bubbling fluidized-bed (0.1 m-i.d., 1.2 m-high) that had continuous solids feed and discharge. Solids were fed in to the upper fluidized-bed and overflowed into the bed section of the lower fluidized-bed through a standpipe (0.025 m-i.d.). The standpipe was simply a dense solids bed with no mechanical or non-mechanical valves. The solids overflowed the lower bed for discharge. The fluidizing gas was fed to the lower fluidized-bed and the exit gas was also used to fluidize the upper bed. Air was used as fluidizing gas and mixture of coarse (< $1000{\mu}m$ in diameter and $3090kg/m^3$ in apparent density) and fine (< $100{\mu}m$ in diameter and $4400kg/m^3$ in apparent density) particles were used as bed materials. The proportion of fine particles was employed as the experimental variable. The gas velocity of the lower fluidized-bed was defined as collapse velocity in the condition that the standpipe was emptied by upflow gas bypassing from the lower fluidized-bed. It could be used as the maximum operating velocity of the present process. The collapse velocity decreased after an initial increase as the proportion of fine particles increased. The maximum took place at the proportion of fine particles 30%. The trend of the collapse velocity was similar with that of standpipe pressure drop. The collapse velocity was expressed as a function of bulk density of particles and voidage of static bed. It increased with an increase of bulk density, however, decreased with an increase of voidage of static bed.

Fe0/C-bentonite alginate beads and oyster shell fixed-bed column combined process to continuously remove N-acetyl-p-aminophenol in persulfate system

  • Wang, Bing-huang;Zhang, Qian;Honga, Jun-ming
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.301-311
    • /
    • 2018
  • In this study, the ion-gelation method was applied to fabricate novel Fe-carbon-bentonite-alginate beads ($Fe^0$/C-BABs). $Fe^0$/C-BABs could effectively control Fe release during persulfate (PS) activation in N-acetyl-p-aminophenol (APAP) oxidation. A novel two-stage approach that combined $Fe^0$/C-BABs and an oyster-shell-filled bed (OSFB) column was developed to address the low pH and high Fe concentration of the effluent of the traditional PS process. The application of the $Fe^0$/C-BABs and OSFB column regulated pH levels and Fe release during the advanced oxidation of APAP. The characteristics of $Fe^0$/C-BABs were also investigated through scanning electron microscopy, energy dispersive spectrometry, and Fourier transform infrared spectroscopy. The long-term operation performance of $Fe^0$/C-BABs in a continuous fixed-bed reactor under simultaneous PS and APAP feeding was also evaluated. The effects of initial PS concentration, pH, fixed-bed weight, in-flow rate, and dissolved oxygen (DO) were investigated. Under selected conditions, 86.3% efficiency was achieved during the first stage of APAP degradation (effluent pH of 3.05, Fe contents: $106.25mgL^{-1}$). Water quality improved after the effluent was passed through the OSFB column (effluent pH of 6.32, Fe contents: $21.43mgL^{-1}$). Moreover, this study analyzed the free radicals and intermediates produced during APAP degradation to identify the possible routes of APAP degradation.

A Study on the Holocene Environments of the Jemin Plain in Gongju, Chungnam Province (충남 공주 제민평야의 홀로세 환경연구)

  • PARK, Ji Hoon;LEE, Ae-Jin
    • Journal of The Geomorphological Association of Korea
    • /
    • v.24 no.2
    • /
    • pp.65-78
    • /
    • 2017
  • In this study, stable carbon isotopic analysis (22 specimens) and magnetic susceptibility analysis (23 specimens) were conducted out on the specimens collected from two points (trench DT1, DT2) in the floodplain of Jemincheon(hereinafter the Jemin plain) to reconstruct the Holocene Environments (Period I, Period II, Period III) of the Jemin plain in Gongju, Chungnam. The results were as follows: In Period I (approximately 7,480~4,940 yrs B.P.) and especially around 7,480~7,320 yrs B.P., it was cool-dry and there were two minor climate fluctuations. This period received a continuous flow of sediments, rather than massive amounts of sediments due to abrupt flooding, and therefore, there was almost no soilization process. Period II(approximately 4,940~2,600 yrs B.P.) was also relatively cool-dry. However, in Period II b, unlike I, the minor climate fluctuations were less pronounced. In this period, flooding and desiccation repeated, inducing soilization processes especially around 3,160 yrs B.P. In Stage III (~360 yrs B.P.), it was warm and humid compared to II b. However, in III a, there was no inflow of sediments due to irregular flooding, and in fact, soilization process was more manifested than during II b due to the impact of the desiccation environment. However, there were some mass movements from Bonghwang Mt. (a.s.l. 147m) caused by heavy rains and typhoon during III b (approximately 360 yrs B.P.), thus moving a large amount of debris (i.e. gravel), which resulted in sedimentation.

Evaluating stability of dam foundations by borehole and surface survey using Step Frequency Radar

  • Jha Prakash C.;Balasubramaniam V. R.;Nelliat Sandeep;Sivaram Y. V.;Gupta R. N.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.328-334
    • /
    • 2003
  • Evaluating stability of dam foundations is one of the prime areas of any rock engineering investigations. Despite best engineering efforts in the design and construction of dam foundations, the foundation regime of a constructed dam suffers deterioration due to continuous erosion from backwater current of dam discharge and dynamic effects of loading and unloading process. Even during construction, development of frequent cracks due to sudden thermal cooling of concrete blocks is not uncommon. This paper presents two case studies from India and Bhutan. In the first case, the back current of water discharge from the Srisailam dam in India had continuously eroded the apron and has eaten into the dam foundation. In the second case with dam construction at Tala Hydroelectric Project in Bhutan, sudden overflow of river during the construction stage of dam had led to development of three major cracks across the dam blocks. This was ascribed to adiabatic cooling effect of concrete blocks overlain by chilled water flow. Non-destructive evaluation of rock mass condition in the defect regime by the borehole GPR survey helped in arriving at the crux so as to formulate appropriate restoration plan.

  • PDF

Case Study on Artificial Intelligence and Risk Management - Focusing on RAI Toolkit (인공지능과 위험관리에 대한 사례 연구 - RAI Toolkit을 중심으로)

  • Sunyoung Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.115-123
    • /
    • 2024
  • The purpose of this study is to contribute to how the advantages of artificial intelligence (AI) services and the associated limitations can be simultaneously overcome, using the keywords AI and risk management. To achieve this, two cases were introduced: (1) presenting a risk monitoring process utilizing AI and (2) introducing an operational toolkit to minimize the emerging limitations in the development and operation of AI services. Through case analysis, the following implications are proposed. First, as AI services deeply influence our lives, the process are needed to minimize the emerging limitations. Second, for effective risk management monitoring using AI, priority should be given to obtaining suitable and reliable data. Third, to overcome the limitations arising in the development and operation of AI services, the application of a risk management process at each stage of the workflow, requiring continuous monitoring, is essential. This study is a research effort on approaches to minimize limitations provided by advancing artificial intelligence (AI). It can contribute to research on risk management in the future growth and development of the related market, examining ways to mitigate limitations posed by evolving AI technologies.

Analysis on Green BIM based Atrium Sizes in the Early Design Stage (Green BIM기반 초기설계 단계에서 타입별 아트리움의 규모산정에 관한 연구)

  • Jeong, Seung-Woo;Lee, Kweon-Hyoung;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.1
    • /
    • pp.58-70
    • /
    • 2013
  • This study for establishing specific standards of atrium design aims to discuss design of atrium to consider energy performance atrium in office buildings. In order to evaluate a type and a scale of atrium at the early design stage, modeling details of mass design were set as standards of conceptual design. In the experiment, Project Vasari was used to analyze modeling and energy consumption, based on the LOD 100-step suggested by AIA, because there is no guideline to specify a level of modeling details at each design process. From this analysis, the correlation among a simple-typed atrium and scale and energy load was considered. The result of this research is as follows: First, the single-sided atrium reduced energy the most, and it was followed by three-sided, two-sided, four-sided and continuous-typed ones. On the whole, they could decrease energy by up to about 15%. Also, the atrium with a wide facade facing in the south was more favorable to reduce energy. Second, planning the atrium within 10~30% of the whole building area was more energy efficient. Third, rather than the depth, adjusting the length in designing an atrium could reduce cooling and heating loads by 1.5% per 1m. As explained above, energy performance evaluation considering types and planning elements of atrium helps to assess alternatives in a reasonable way. In particular, considering the use of building needs to be preceded to select a type of atrium, although it is also important to consider its planning elements.

Study on the Hydrogenation and Isomerization Reaction of Dimethylcyclopentadiene (디메틸시클로펜타디엔의 수소화 및 이성화반응 연구)

  • Jeong, Byung Hun;Han, Jeong Sik;Lee, Jeong Ho;Kim, Seong Bo;Lee, Bum Jae
    • Korean Chemical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.566-570
    • /
    • 2005
  • The study on the hydrogenation and isomerization of unsaturated bicyclic hydrcarbon compounds using methylcyclopentadiene dimer (MCPD) was carried out. Exo compound was prepared through isomerization reaction after two hydrogenation reaction steps. In the first hydrogenation reaction which needs one mole of hydrogen, the formation rate of monomer was increased as dimer was decomposed at reaction temperature above $100^{\circ}C$. At first hydrogenation, DHDMCPD [dihydrodi(methylcyclopentadiene)] was formed and second hydrogenation was proceeded to produce THDMCPD [tetrahydrodi(methylcyclopentadiene)], the ratio of exo to endo THDMCPD was varied by the control of 2nd hydrogenation temperature. To improve the process, continuous 1st and 2nd hydrogenation conditions were established by using the 2nd stage heat controllable reactor. Also, catalytic activities were compared by the use of halogenized aluminum, metal halides and solid acids catalysts on the isomerization reaction from endo to exo THDMCPD.

Analysis on Green BIM based Atrium Sizes in the Early Design Stage

  • Jeong, Seung-Woo;Lee, Kweon-Hyoyng;Choo, Seung-Yeon
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.260-266
    • /
    • 2013
  • This study for establishing specific standards of atrium design aims to discuss design of atrium to consider energy performance according to the types of atrium of office building. In order to evaluate a type and a scale of atrium at the early design stage, modeling details of mass design were set as standards of conceptual design. In the experiment, Project Vasari was used to analyze modeling and energy consumption, based on the LOD 100-step suggested by AIA, because there is no guideline to specify a level of modeling details at each design process. From this analysis, the correlation among a simple-typed atrium and scale and energy load was understood, and the followings are the considerations for designing an atrium. First, the single-sided atrium reduced energy the most, and it was followed by three-sided, two-sided, four-sided and continuous-typed ones. On the whole, they could decrease energy by up to about 15%. Also, the atrium with a wide facade facing in the south was more favorable to reduce energy. Second, planning an atria within 10~30% of the whole building area was more energy efficient. Third, rather than the depth, adjusting the length in designing an atrium could reduce cooling and heating loads by 1.5% per 1m. As explained above, energy performance evaluation considering types and planning elements of atrium helps to assess alternatives in a reasonable way. In particular, considering the use of building needs to be preceded to select a type of atrium, although it is also important to consider its planning elements.

  • PDF

Growth Performance of Teak (Tectona grandis Linn f.) and Padauk (Pterocarpus macrocarpus Kurz) Used in the Enrichment Planting for the Restoration of Degraded Tropical Forests in Myanmar

  • Oo, Thaung Naing;Lee, Don Koo;Park, Yeong Dae
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.5
    • /
    • pp.540-546
    • /
    • 2008
  • Enrichment planting has been used as one of the promising restoration techniques to accelerate the natural restoration process of secondary forests or logged-over forests in Myanmar, The objectives of this study were to examine the growth performances of two commercial species such as Teak (Tectona grandis Linn f.) and Padauk (Pterocarpus macrocarpus Kurz) in response to different canopy opening treatments and to examine the suitability of these species in enrichment planting activities for the restoration of degraded tropical forests in Myanmar. In this study, split plot design was applied, and three levels of canopy openings were experimented. The survival rate and height growth of two species were measured four times with 6 month interval. The root collar diameter (RCD) was also measured in the last assessment. Although the survival rate of seedlings was not significantly different among the three treatments (p>0.05) as well as between two species (p>0.05) for all consecutive measurements, height (p<0.05) and RCD were significantly different (p<0.001) among the treatments, T. grandis seedlings thrived best under complete canopy opening (i.e., 5 m width canopy opening with strip-clear cutting) while P. macrocarpus seedlings under partial canopy opening (without felling of marketable tree species). Because this study is concerned with only for young stage of seedlings, continuous assessment and follow-up tending activities are needed to verify the species suitability and optimum width of canopy opening for enrichment planting activities in restoration of degraded forests of Myanmar.