• Title/Summary/Keyword: two-component link

Search Result 39, Processing Time 0.022 seconds

An Efficient Power Control Algorithm for Satellite Communications Systems with ATC

  • Kim, Byung-Gi;Ryoo, Sang-Jin;Hwang, In-Tae
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.2
    • /
    • pp.129-133
    • /
    • 2008
  • In this paper, modified power control algorithms are proposed for a satellite mobile communications system with ATC (ancillary terrestrial component). In order to increase system capacity and reduce the transmitting power of the user's equipment, we propose the modified power control scheme consisting of the modified closed-loop and open-loop power control. The modified CLPC (closed-loop power control) algorithm, combining the delay compensation algorithms and pilot diversity, is mainly applied to the ATC link in urban areas because it is more suitable to the short RTD (round-trip delay). In the case of rural areas where ATCs are not deployed or a signal is not received from ATCs, combining monitoring transmitting power equipment and OLPC (open-loop power control) algorithms using an efficient pilot diversity is mainly applied to the link between the user's equipment and the satellite. Two power control algorithms are applied equally to the boundary areas where two kinds of signals are received in order to ensure coverage continuity. The simulation results show that the modified power control scheme has good performance compared to conventional power control schemes in a GEO (geostationary earth orbit) satellite system with ATC.

A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters (소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법)

  • In, Hyo-Chul;Kim, Seok-Min;Park, Seong-Soo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

Invariant Trace Fields of Chain Links

  • Ryou, Kazuhiro
    • Kyungpook Mathematical Journal
    • /
    • v.56 no.1
    • /
    • pp.257-271
    • /
    • 2016
  • In this paper, we compute the trace field of C(2, s), the complement of two component chain link with s left half twists in ${\mathbb{S}}^3$, for every s. As a result, for every $n{\in}{\mathbb{N}}{\backslash}\{1\}$, we can find $s{\in}{\mathbb{Z}}$ such that the degree of the trace field of C(2, s) is n. We also prove that if for fixed p, the degree of the trace field of C(p, s) runs over ${\mathbb{N}}{\backslash}\{1\}$, then p is contained in {1, 2, 4, 8}.

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.

Optimization of Transportation Problem in Dynamic Logistics Network

  • Chung, Ji-Bok;Choi, Byung-Cheon
    • Journal of Distribution Science
    • /
    • v.14 no.2
    • /
    • pp.41-45
    • /
    • 2016
  • Purpose - Finding an optimal path is an essential component for the design and operation of smart transportation or logistics network. Many applications in navigation system assume that travel time of each link is fixed and same. However, in practice, the travel time of each link changes over time. In this paper, we introduce a new transportation problem to find a latest departing time and delivery path between the two nodes, while not violating the appointed time at the destination node. Research design, data, and methodology - To solve the problem, we suggest a mathematical model based on network optimization theory and a backward search method to find an optimal solution. Results - First, we introduce a dynamic transportation problem which is different with traditional shortest path or minimum cost path. Second, we propose an algorithm solution based on backward search to solve the problem in a large-sized network. Conclusions - We proposed a new transportation problem which is different with traditional shortest path or minimum cost path. We analyzed the problem under the conditions that travel time is changing, and proposed an algorithm to solve them. Extending our models for visiting two or more destinations is one of the further research topics.

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

Ranking Quality Evaluation of PageRank Variations (PageRank 변형 알고리즘들 간의 순위 품질 평가)

  • Pham, Minh-Duc;Heo, Jun-Seok;Lee, Jeong-Hoon;Whang, Kyu-Young
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.5
    • /
    • pp.14-28
    • /
    • 2009
  • The PageRank algorithm is an important component for ranking Web pages in Google and other search engines. While many improvements for the original PageRank algorithm have been proposed, it is unclear which variations (and their combinations) provide the "best" ranked results. In this paper, we evaluate the ranking quality of the well-known variations of the original PageRank algorithm and their combinations. In order to do this, we first classify the variations into link-based approaches, which exploit the link structure of the Web, and knowledge-based approaches, which exploit the semantics of the Web. We then propose algorithms that combine the ranking algorithms in these two approaches and implement both the variations and their combinations. For our evaluation, we perform extensive experiments using a real data set of one million Web pages. Through the experiments, we find the algorithms that provide the best ranked results from either the variations or their combinations.

A Simple Approach for Determining No-Passing Zones in Two-Lane Rural Highways

  • Son, Bong-Soo
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.09a
    • /
    • pp.141-151
    • /
    • 1998
  • Provision of Passing Sight Distance (PSD) is an important component in two-lane highway design and has a critical impact on capacity of highway and safety of drivers. Many models have been developed to estimate PSD reasonably. However, each of them has a number of shortcomings for reflecting the real traffic conditions. This paper introduces a revised model that reflects the characteristics of the passing maneuver. The changes in passing sight distances under different assumptions about acceleration and vehicle length, which are related to vehicle types, are presented. The results obtained by the revised model are compared with those obtained from the existing models. There is an important link between geometric design decisions which determine the available sight distance and the quality of service which the road provides. In this paper, we examine one aspect of this relationship. That is to determine whether the passing sight distance is provided by improving horizontal alignment for a specific roadway section or passing may be restricted to save the road construction cost. To do so, a simple method for estimating traffic delay in no-passing is introduced.

  • PDF

Combining Adaptive Filtering and IF Flows to Detect DDoS Attacks within a Router

  • Yan, Ruo-Yu;Zheng, Qing-Hua;Li, Hai-Fei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.3
    • /
    • pp.428-451
    • /
    • 2010
  • Traffic matrix-based anomaly detection and DDoS attacks detection in networks are research focus in the network security and traffic measurement community. In this paper, firstly, a new type of unidirectional flow called IF flow is proposed. Merits and features of IF flows are analyzed in detail and then two efficient methods are introduced in our DDoS attacks detection and evaluation scheme. The first method uses residual variance ratio to detect DDoS attacks after Recursive Least Square (RLS) filter is applied to predict IF flows. The second method uses generalized likelihood ratio (GLR) statistical test to detect DDoS attacks after a Kalman filter is applied to estimate IF flows. Based on the two complementary methods, an evaluation formula is proposed to assess the seriousness of current DDoS attacks on router ports. Furthermore, the sensitivity of three types of traffic (IF flow, input link and output link) to DDoS attacks is analyzed and compared. Experiments show that IF flow has more power to expose anomaly than the other two types of traffic. Finally, two proposed methods are compared in terms of detection rate, processing speed, etc., and also compared in detail with Principal Component Analysis (PCA) and Cumulative Sum (CUSUM) methods. The results demonstrate that adaptive filter methods have higher detection rate, lower false alarm rate and smaller detection lag time.