• Title/Summary/Keyword: two faults

Search Result 504, Processing Time 0.023 seconds

Model of Remote Service and Fault Diagnosis for CNC Machine Tool (공작기계의 지능형 고장진단 및 원격 서비스 모델)

  • 김선호;김동훈;이은애;한기상;김주한
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.92-97
    • /
    • 2001
  • The major faults of CNC machine tool is operational error which is charge over 70%. This paper describes model of remote service and fault diagnosis for CNC machine tool with open architecture controller. For intelligent fault diagnosis, new model is proposed. In this paper, the three major operational faults, emergency stop error, cycle start disable and machine ready disable, are defined. Two diagnostic models based on the ladder diagram, switching function model, step switching function model, are proposed. For internet based remote service, suitable environment is proposed and implemented with web server and client.

  • PDF

Partial Discharge Distribution Characteristics along Defect of CNC Cable (배전급 CNC케이블의 결함 종류에 따른 부분방전 분포특성)

  • Yoon, Jae-Hun;Kang, Seung-Hwa;Choi, Han-Sick;Lim, Gee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.102-102
    • /
    • 2010
  • A purpose of this paper is to recognize partial discharge pattern for cable insulation. The classification of PD sources was widely studied for two decades. this research sought to use the partial discharge detection method, and to diagnose the interface of cable, which is deemed vulnerable of cable systems. A research abalyzed faults that can occur in the interface of cable joint as well as accident mechanisms, manufactured test 22.9kV CNC cable, invented artificial faults and carried out partial discharge detection experiments. As a result, various PD pattern along defect measured and distinguished.

  • PDF

Implementation and Performance Analysis of a Fault-tolerant Mini-MAP System (결함 허용 Mini-MAP 시스템의 구현 및 성능해석)

  • 문홍주;박홍성;권욱현
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.3
    • /
    • pp.1-10
    • /
    • 1995
  • In this paper, a fault-tolerant Mini-MAP system with high reliability is proposed. For fault-tolerance, the LLC sublayer, MAC sublayer, and physical layer of the Mini-MAP system are dualized. The detection of faults, the replacement of the failed network, and the management of the network are three major functions required for the dualization, and they are performed by ESM(Error Supervisory Machine), EMM(Error Management Machine), and NMM(Network Management Machine) of the proposed fault-tolerant Mini-MAP system, respectively. The ring maintenance function of the MAC sublayer is used for the detection of the faults. In the proposed fault-tolerant Mini-MAP system, the data are received from both of the dualized networks and transmitted to the selected one of the two. We analyze the reliability and the MTTF(Mean Time To Failure) of the proposed fault-tolerant Mini-MAP system and show that it has better performance compared to a general Mini-MAP system.

  • PDF

Analysis on the Effect of Arcing Fault and CT Saturation on Distance Algorithms (아크고장 및 CT포화가 거리계전 알고리즘에 미치는 영향분석)

  • Son, Chun-Myung;Kang, Sang-Hee;Kang, Yong-Choel;Rebizant, Waldemar
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.50-52
    • /
    • 2002
  • Distance relays need accurate current and voltage for determining the trip ignition. Therefore we must analyze nonlinear phenomena which cause distortion in signals first of all. This paper presents the effect of some distortion(arcing fault and current transformer saturation) in power system. The saturation of a current transformer distorts input current of a distance relay and arcing faults make current and voltage to be changed. This paper describes modeling methods of a current transformer and arcing faults, and describes the simulation result of two distance relay algorithms (discrete fourier transform and modified differential equation methods)

  • PDF

An Empirical Study on Faults Prediction for Large Scale Telecommunication Software (대규모 통신 소프트웨어의 결함 수 예측에 관한 사례 연구)

  • Park, Young-Sik;Yoon, Byeong-Nam;Lim, Jae-Hak
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.2
    • /
    • pp.263-276
    • /
    • 1999
  • In this paper, we consider the change request data collected from the system test of a large-scale telecommunication software and analyze the types and causes of failures. And we develop statistical models that incorporate a functional relation between the faults and some software metrics. To this end, we consider three possible regression models including a stepwise regression model and two nonlinear models. Three developed models are evaluated with respect to the predictive quality. We also discuss the advantage of proposed models and the application of our model to a new project.

  • PDF

Pilots' Understandings on the Pilot Education Curriculum and Teaching-Learning Methods (조종사교육 교과목과 교수;학습방법에 대한 조종사의 의식)

  • Choi, Y.K.;Suh, J.H.;Kim, I.C.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.8 no.1
    • /
    • pp.95-109
    • /
    • 2000
  • The analyses of the aircraft accidents across all of the world, including Korea, reported that 70 % of the accidents could be attributed to the faults of pilots' human factors. It implied that the aircraft accidents could be cut down remarkably if the pilots' faults were reduced. In this context, the purpose of the study were to explore and reduce the problems of authoritarian job performance in the cockpit operation of which mainly depended on the captain, though it was supposed that two or more pilots work together as a team. In relation to this, the current worldwide trend of pilot education had tended to emphasize education on the human factors of pilots since the strong recommendation of the International Civil Aviation Organization in the 1980's. From the educational dimension of the pilots, it was attempted to explore a new educational perspective which would enhance the flight crew's performance of the cockpit through improving the courses of the pilot education curriculum and the teaching-learning methods.

  • PDF

An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier (베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구)

  • Lee, Heung-Ju;Chang, Young-Soo;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet-Transforms and Back-propagation Neural Networks

  • Ngaopitakkul Atthapol;Kunakorn Anantawat
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.365-371
    • /
    • 2006
  • This paper presents an algorithm based on a combination of Discrete Wavelet Transforms and neural networks for detection and classification of internal faults in a two-winding three-phase transformer. Fault conditions of the transformer are simulated using ATP/EMTP in order to obtain current signals. The training process for the neural network and fault diagnosis decision are implemented using toolboxes on MATLAB/Simulink. Various cases and fault types based on Thailand electricity transmission and distribution systems are studied to verify the validity of the algorithm. It is found that the proposed method gives a satisfactory accuracy, and will be particularly useful in a development of a modern differential relay for a transformer protection scheme.

Agent-Based Distance Relaying Algorithm for Phase-to-Ground Faults (에이전트 환경에서의 1선지락 거리계전 알고리즘)

  • Hyun, Seung-Ho;Jin, Bu-Gun;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1885-1891
    • /
    • 2007
  • This paper presents a distance relaying algorithm for phase-to-ground faults in transmission lines under Multi-Agent protection environment. In normal condition, a distance relay agent stores the latest states, e.g., voltage of source side, voltage of the opposite side and the loading conditions, etc., through communication between the agents. Once a fault occurs, the relay calculates the fault location using the knowledge about the states just before the fault happens. This stand-alone operation is to improve reliability under the fault condition at which the accuracy or time required for communication may not be guaranteed. The mathematical expression of fault location is derived through loop analysis, before hand, in the manner that both fault current from the opposite end and fault resistance are included implicitly so that their effects are minimized. The suggested algorithm is applied to a typical transmission system with two power sources on both ends to show its effectiveness.

Voltage-controlled Over-current Relay for Loop-connected Distributed Generators (환상형 분산전원 단지 보호를 위한 전압제어 과전류 계전기)

  • Kim, Tae-Hee;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1979-1985
    • /
    • 2016
  • A protection algorithm using a voltage-controlled overcurrent element for a looped collection circuit in a wind farm is suggested in this paper. Because the proposed algorithm uses voltage relaying signals as well as current relaying signals, any fault in the looped collection circuit can be cleared by voltage-controlled overcurrent relays located at the two adjacent relaying points, the nearest place in each direction from the fault point. The algorithm can also distinguish the external faults which occur at the outside of a wind farm from the internal faults. It means that the proposed algorithm can provide the proper ability of protection coordination to the relays in the looped collection circuits of a large wind farm. The performance of the proposed algorithm is verified under various fault conditions using PSCAD/EMTDC simulations.