Development of the U-turn Accident Model at 4-Legged Signalized Intersections in Urban Areas (도시부 4지 신호교차로 유턴 사고모형 개발)

  • Kang, JongHo;Kim, KyungWhan;Ha, ManBok;Kim, SeongMun
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.119-129
    • /
    • 2014
  • PURPOSES : The purpose of this study is to develop the U-turn accident model at 4-legged signalized intersections in urban areas. METHODS : In order to analyze the characteristics of the accidents which are associated with U-turn operation at 4-legged signalized intersections in urban areas and develop an U-turn accident model by regression analysis, the tests of overdispersion and zero-inflation are conducted about the dependent variables of number of accidents and EPDO (Equivalent Property Damage Only). RESULTS : As their results, the Poisson model fits best for number of accident and the ZIP (Zero Inflated Poisson) fits best for EPOD, the variables of conflict traffic, width of opposing road, traffic passing speed are adopted as independent variable for both models. The variables of number of bus berths and rate of U-turn signal time at which the U-turn is permitted are adopted as independent variable only for EPDO. CONCLUSIONS : These study results suggest that U-turn would be permitted at the intersection where the width of opposing road is wider than 11.9 meters, the passing vehicle speed is not high and U-turn operation is not hindered by the buses stopping at bus stops.

Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio (자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.

Development of the U-turn Accident Model at Signalized Intersections in Urban Areas by Logistic Regression Analysis (로지스틱 회귀분석에 의한 도시부 신호교차로 유턴 사고모형 개발)

  • Kang, Jong Ho;Kim, Kyung Whan;Kim, Seong Mun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.1279-1287
    • /
    • 2014
  • The purpose of this study is to develop the U-turn accident model at signalized intersections in urban areas. The characteristics of the accidents which are associated with U-turn operation at 3 and 4-legged signalized intersections was analyzed and the U-turn accident model was developed by regression analysis in Changwon city. First, in order to analyze the effectiveness on traffic accidents by U-turn installation, the difference of mean of traffic accident number are measured between two groups which are composed by whether or not U-turn installation the groups by Mann-Whitney U test. The result of significance test showed that intergroup comparison on mean by accident types made difference except rear-end accident type and by accident locations exit section only showed difference in significance level at 4-legged intersections, so the accident number have more where the U-turn is permitted than not. Response measures about the number of accidents were classified by whether accidents occurred and accident model were constructed using binomial logistic regression analysis method. The developed models show that the variables of conflict traffic, number of opposing lane are adopted as independent variable for both intersections. The variables of longitudinal grade for 3-legged signalized intersection and number of crosswalk for 4-legged signalized intersection at which the U-turn is permitted is adopted as independent variable only. These study results suggest that U-turn would be permitted at the intersection where the number of opposing lane is more than 3.5 each, the longitudinal grade of opposing road is upward flow and there is need to establish the U-turn traffic sign at signalized intersections.

Optimal Design of Matrix-type SFCLs According to Turn Number of Reactors (리액터의 권선수에 따른 매트릭스형 한류기 최적화 설계)

  • Chung, Dong Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1944-1947
    • /
    • 2012
  • In this work, we investigated quench characteristics of matrix-type superconducting fault current limiters (MFCLs) according to the turn number of reactors. The reactors used in MFCLs apply magnetic field to superconducting elements within reactors when fault currents surge into MFCL systems. It makes the fast and simultaneous quenches between superconducting elements. Also reactors decrease the fault power burden of superconducting elements by bypassing the partial fault currents to itself, when quench occurs. These structure proposed in this work can be expected to achieve much more current limiting capacity even though it uses less superconductors compared with other type SFCLs. Three reactors were made by Bakelite. These reactors with the turn number of 190, 380 and 570, had the length of 270 mm and diameter of 80 mm. We reported experimental results, including fault currents, fault voltages and resistance in superconducting elements according to the turn number of reactors. We confirmed that experimental results will be useful in next future plan for the real power grid.

A Study on Characteristic of Spiral Inductor with Patterned Ground Shield (패턴드 그라운드 쉴드를 적용한 나선형 인덕터 특성 연구)

  • Ko, Jae-Hyeong;Kim, Hyeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.272-273
    • /
    • 2007
  • This paper presents the characteristic of rectangular and octagonal spiral inductor using PGS(Patterned Ground Shield). We investigated variation of inductance and Q-factor with changing of turn number at fixed width, spacing and inner diameter. We confirmed that characteristic of inductance and Q-factor be appled PGS in rectangular and octagonal types spiral inductor by EM simulation tool. Inductance decreased irrespective of structure but Q-factor increased. When PGS not exist, Q-factor of Inductor is analogous at classification frequency but, rectangular is a few larger then octagonal in small turn number. The other side, When PGS is inserted, we confirmed that octagonal lager then rectangular in many turn number. Q-factor is improved in case of octagonal structure and small turn number by PGS effect.

  • PDF

A Study on the Socio-economic Effects of U-turn Migration in Rural Area (귀농(歸農)이 농촌사회(農村社會)에 미치는 영향(影響)에 관한 연구(硏究))

  • Kim, Jai-Hong
    • Korean Journal of Agricultural Science
    • /
    • v.25 no.1
    • /
    • pp.138-147
    • /
    • 1998
  • U-turn migration is one of the prominent phenomenon after IMF controlled Korean economy. However a number of U-turn migrants were settled in rural area before that time. This paper is aims at studying the socio-economic effects of U-turn migration in rural area. The study results are summarized as follows; First, migrants are relatively young and engaged in overall parts of the farming. The farmer with age under 50 is represented at 71.4% of migrants comparing with 53.7% of those farmers in rural area. Second, owing to the increasing number of U-turn migrants, the decreasing price of rural wages, the decreasing of idle land, and the increasing price of farm land are the outstanding phenomenon at present. Third, even though there are many kinds of supporting systems for U-turn migrants, the systems are not so successfully functioned. For the successful supporting system they must be changed for the individual migrant rather than target group.

  • PDF

Determination of Optimal Turn-off Angle for SRM Converter Using Self-Tuning Method (SRM 컨버터에서 자기동조 방식에 의한 턴오프 각의 결정)

  • 장도현;문진영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.418-425
    • /
    • 1998
  • In this paper. determination method of turn-off angle in the SRM drives is proposed to maintain the high torque at a any turn-on angle, which is realized by using selHuning control method, During the sampling time. a number of P pulses from encoder are checked by using one-chip microprocessor. and compared with pre-checked a number of pulses A After calculating difference between two data, the turn-off angle moves forward or backward direction by the self-tuning m method, As repeating such process, the optimal turn-off angle is determined and the maximum torque is maintained T Though experiments, it is observed that motor speed is almost maintained if turn-off angle is adjusted automatically by s selHuning method when turn-ηn angle is changed.

  • PDF

Self-Tuning Control of SRM for Maximum Torque with Current and Shaft Position Feedback

  • Seo Jong-yun;Yang Hyong-yeol;Kim Kwang-Heon;Lim Young-Cheol;Cha Hyun-Rok;Jang Do-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.351-354
    • /
    • 2001
  • In this paper, we present self-tuning control of switched reluctance motor for maximum torque with phase current and shaft position sensor. Determination method of turn-on/off angle is realized by using self-tuning control method. During the sampling time, micro-controller checks the number of pulse from encoder and compare with the number of pre-checked pulse. After micro-controller calculates between two data, it moves forward or backward turn-off angle. When the turn-off angle is fixed optimal turn-off angle, the turn-on angle automatically moves forward or backward by a step using self-tuning control method. And then, optimal turn-off angle is searched once again. As such a repeating process, turn-on/off angle is moved automatically to obtain the maximum torque. The experimental results are presented to validate the self-tuning algorithm.

  • PDF

Impacts of Pre-signals on Traffic Crashes at 4-leg Signalized Intersections (전방신호기가 교통사고에 미치는 영향 연구)

  • Kim, Byeongeun;Lee, Youngihn
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.135-146
    • /
    • 2013
  • PURPOSES : This study aimed to analyze the impact the operation of pre-signals at 4-leg signalized intersections and present primary environmental factors of roads that need to be considered in the installation of pre-signals. METHODS : Shift of proportions safety effectiveness evaluation method which assesses shifts in proportions of target collision types to determine safety effectiveness was applied to analyze traffic crash by types. Also, Empirical Bayes before/after safety effectiveness evaluation method was adapted to analyze the impact pre-signal installation. Negative binomial regression was conducted to determine SPF(safety performance function). RESULTS : Pre-signals are effective in reducing the number of head on, right angle and sideswipe collisions and both the total number of personal injury crashes and severe crashes. Also, it is deemed that each factor used as an independent variable for the SPF model has strong correlation with the total number of personal injury crashes and severe crashes, and impacts general traffic crashes as a whole. CONCLUSIONS: This study suggests the following should be considered in pre-signal installation on intersections. 1) U-turns allowed in the front and rear 2) A high number of roads that connect to the intersection 3) Many right-turn traffic flows 4) Crosswalks installed in the front and rear 5) Insufficient left-turn lanes compared to left-turn traffic flows or no left-turn-only lane.

An One-To-One K-Shortest Path Algorithm Considering Vine Travel Pattern (덩굴망 통행패턴을 고려한 One-To-One 다경로알고리즘)

  • Lee, Mee-Young;Yu, Ki-Yun;Kim, Jeong-Hyun;Shin, Seong-Il
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.6
    • /
    • pp.89-99
    • /
    • 2003
  • Considering a path represented by a sequence of link numbers in a network, the vine is differentiated from the loop in a sense that any link number can be appeared in the path only once, while more than once in the loop. The vine provides a proper idea how to account for complicated travel patterns such as U-turn and P-turn witnessed nearby intersections in urban roads. This paper proposes a new algorithm in which the vine travel pattern can be considered for finding K number of sequential paths. The main idea of this paper is achieved by replacing the node label of the existing Yen's algorithm by the link label technique. The case studies show that the algorithm properly represent the vine travel patterns in searching K number of paths. A noticeable result is that the algorithm may be a promising alternative for ITS deployment by enabling to provide reasonable route information including perceived traveler costs.